Addressing the critical challenge of signal degradation in biosensor cardiac monitoring, this paper introduces an efficient hybrid dilated–long short-term memory (LSTM) with residual learning (HDLR), which is a novel architecture engineered for a high-fidelity electrocardiogram (ECG) denoising signal. The proposed HDLR model synergistically integrates with dilated convolutions to expand the receptive field for multi-scale feature extraction. This is an LSTM-based backbone used to resolve long term temporal dependencies with residual learning paths to stabilize gradient flow and accelerate convergence. The proposed HDLR architecture integrates three core functional components with dilated convolutional layers utilized for local temporal feature extraction, where varying dilation rates expand the receptive field to capture both local waveform patterns and broader morphological structures without increasing computational complexity. Experimental results demonstrate a significant leap in performance, with the HDLR model achieving a mean squared error (MSE) of 0.002176, a signal-to-noise ratio (SNR) of 14.4420 dB, and a Matthews correlation coefficient (MCC) of 0.9822. Beyond quantitative metrics, the proposed HDLR architecture exhibits exceptional robustness in preserving cardiac morphology, specifically the P-wave and QRS complex of the ECG signal under stochastic noise conditions. These findings underscore the HDLR model’s potential as a backbone for next generation, real time diagnostic systems in intelligent healthcare.
1 October 2025 in International Journal of Electrical and Computer Engineering (IJECE)
This paper presents the human fall detection using body location (HFBL) and posture geometry. The main contribution of the proposed HFBL system is to reduce the computational complexity of fall detection system while maintaining accuracy, as most fall detection techniques rely on computationally complex algorithms from machine learning or deep learning. This approach examines the human posture by applying the image segmentation and ratio by posture geometry. Then, the distance transform is used to calculate the high brightness points on the human body. These points are the maximum values compared with the edge values. Afterward, one of these points is selected as a center point. A line is formed by this center point aligned horizontally to separate the upper area and lower area, then an intersection line is drawn through this center point vertically that can separate the four quadrants of body location. With the help of posture geometry, the angles are employed for prediction “Fall” or “NotFall” actions at each frame of video sequence. Referring to the dynamic balance, the ratio between the distance vectors from the center point to the right and left legs is calculated to confirm fall and non-fall activities, utilizing the Pythagorean trigonometric identity. For experiments, 2,542 images from the UR fall detection dataset, with dimensions of 640×480×3 were prepared through image segmentation to find the human body shape for analysis using the proposed HFBL system. Results demonstrate that the low computational HFBL approach can provide 91.23% accuracy, the precision value is 99.14%, the recall value is 84.48%, and the F1-score value is 91.22%.
This paper introduces an electrocardiogram (ECG) noise removal front-end amplifier circuit based on a current-feedback operational amplifier (CFOA) that uses the current feedback to detect error signals and control the output. This ECG circuit focuses on denoising the ECG noise to accentuate the ECG electrical signals from the heart. Noises in ECG refer to baseline wander (BW), powerline interference (PLI) and motion artifacts. We proposed a CFOA-based ECG pre-amplifier using the AD844 commercial operational amplifier built inside with a positive second-generation current conveyor (CCII+) and a voltage follower circuit. This work introduces an ECG noise removal front-end amplifier based on a CFOA. The primary innovation lies in the balancing instrumentation amplifier architecture that utilizes the high-speed and robust properties of the AD844 commercial operational amplifier to achieve superior noise rejection. To protect against high-frequency interference, we introduce a novel cascaded low-pass filter (LPF) stage that ensures a sharper cut-off compared to traditional single-stage designs. Experimental results validate the design’s effectiveness, achieving a high common-mode rejection ratio (CMRR) of 75.4 dB and a mid-band gain of 46.5 dB. These performance metrics, combined with the circuit’s ability to eliminate BW and PLI, confirm its robust suitability for high-fidelity wearable ECG monitoring.