In this brief, a $2{^{\text {nd}}}$ -order $g_{\mathrm { m}} - C$ lowpass filter with a practical input linear range of $400~{\mathrm { mV}}_{\mathrm { P}}$ dedicated to ECG signal acquisition is proposed. This filter employs a degenerative source-coupled-pair circuit as a $g_{\mathrm { m}}$ cell. It enhances the linear input range by a factor of $\times 4$ compared with the source follower filter. Additionally, to mitigate the effect of current source mismatch, a dynamic element matching technique is applied. By doing so, HD2 is suppressed more than 1.5 dB over the entire passband frequency. This proposed filter is implemented in a $0.18~\mu $ m CMOS process. It offers a 250-Hz bandwidth with input-referred noise and a dynamic range of $82.1~\mu {\mathrm { V}}_{\mathrm {\mathrm {rms}}}$ and 67.34 dB, respectively. The power consumption of 38.4 nW is achieved with a 1.2 V supply. Compared with other recent nano-power filters, the proposed filter provides the highest linear input range with competitive Figure-of-Merit to the top-tier designs. It is therefore beneficial to the practical implementation of a low-power ECG acquisition system.
A noninteracting electronically tunable universal filter is proposed in this paper. The proposed circuit can simultaneously realize highpass, lowpass and bandpass transfer functions without changing the circuit topology. Also, the circuit is implemented by using four CCCIIs with controlled current gain and two grounded capacitors which is suitable for IC implementation. Moreover, the proposed circuit can be simply modified to achieve bandstop and all pass responses. The parameters omega, Q and H0 of the filter are independently tunable. The PSPICE simulation results show that the proposed filter performs its function property
This paper introduces an electrocardiogram (ECG) noise removal front-end amplifier circuit based on a current-feedback operational amplifier (CFOA) that uses the current feedback to detect error signals and control the output. This ECG circuit focuses on denoising the ECG noise to accentuate the ECG electrical signals from the heart. Noises in ECG refer to baseline wander (BW), powerline interference (PLI) and motion artifacts. We proposed a CFOA-based ECG pre-amplifier using the AD844 commercial operational amplifier built inside with a positive second-generation current conveyor (CCII+) and a voltage follower circuit. This work introduces an ECG noise removal front-end amplifier based on a CFOA. The primary innovation lies in the balancing instrumentation amplifier architecture that utilizes the high-speed and robust properties of the AD844 commercial operational amplifier to achieve superior noise rejection. To protect against high-frequency interference, we introduce a novel cascaded low-pass filter (LPF) stage that ensures a sharper cut-off compared to traditional single-stage designs. Experimental results validate the design’s effectiveness, achieving a high common-mode rejection ratio (CMRR) of 75.4 dB and a mid-band gain of 46.5 dB. These performance metrics, combined with the circuit’s ability to eliminate BW and PLI, confirm its robust suitability for high-fidelity wearable ECG monitoring.