Daniele Dondossola

Dr. Daniele Dondossola

1. Fondazione IRCCS Ca’ Granda Ospedale Maggiore Policlinico, Milan, Italy
+1
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2016 in Anesthesiology
Verified
Journal Article
Open access
PDF file
MCMassimo Cressoni
Massimo Cressoni
MGMiriam Gotti
Miriam Gotti
CCChiara Chiurazzi
Chiara Chiurazzi
DMDario Massari
Dario Massari
IAIlaria Algieri
Ilaria Algieri
LGLuciano Gattinoni
Luciano Gattinoni
Twenty-four anesthetized piglets ventilated with a range of tidal volume and respiratory rate developed widespread lung injury above a threshold of 12 J/min. This finding suggests that mechanical power applied may be taken into account for ventilator-induced lung injury prevention. Supplemental Digital Content is available in the text. Background: The ventilator works mechanically on the lung parenchyma. The authors set out to obtain the proof of concept that ventilator-induced lung injury (VILI) depends on the mechanical power applied to the lung. Methods: Mechanical power was defined as the function of transpulmonary pressure, tidal volume (TV), and respiratory rate. Three piglets were ventilated with a mechanical power known to be lethal (TV, 38 ml/kg; plateau pressure, 27 cm H2O; and respiratory rate, 15 breaths/min). Other groups (three piglets each) were ventilated with the same TV per kilogram and transpulmonary pressure but at the respiratory rates of 12, 9, 6, and 3 breaths/min. The authors identified a mechanical power threshold for VILI and did nine additional experiments at the respiratory rate of 35 breaths/min and mechanical power below (TV 11 ml/kg) and above (TV 22 ml/kg) the threshold. Results: In the 15 experiments to detect the threshold for VILI, up to a mechanical power of approximately 12 J/min (respiratory rate, 9 breaths/min), the computed tomography scans showed mostly isolated densities, whereas at the mechanical power above approximately 12 J/min, all piglets developed whole-lung edema. In the nine confirmatory experiments, the five piglets ventilated above the power threshold developed VILI, but the four piglets ventilated below did not. By grouping all 24 piglets, the authors found a significant relationship between the mechanical power applied to the lung and the increase in lung weight (r 2 = 0.41, P = 0.001) and lung elastance (r 2 = 0.33, P < 0.01) and decrease in Pao 2/Fio 2 (r 2 = 0.40, P < 0.001) at the end of the study. Conclusion: In piglets, VILI develops if a mechanical power threshold is exceeded.

10 June 2023 in Journal of Hepatology
Verified
Journal Article
Closed access
APAlessandro Parente
Alessandro Parente
FTFabio Tirotta
Fabio Tirotta
APAlessia Pini
Alessia Pini
JEJanina Eden
Janina Eden
DDDaniele Dondossola
Daniele Dondossola
ASAndrea Schlegel
Andrea Schlegel

4 February 2023 in Journal of Hepatology
Verified
Journal Article
Open access
JEJanina Eden
Janina Eden
RSRichard Xavier Sousa Da Silva
Richard Xavier Sousa Da Silva
MCMiriam Cortes-Cerisuelo
Miriam Cortes-Cerisuelo
KCKristopher Croome
Kristopher Croome
RCRiccardo De Carlis
Riccardo De Carlis
PDPhilipp Dutkowski
Philipp Dutkowski
Liver graft utilization rates are a hot topic due to the worldwide organ shortage and the increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially enable the assessment of livers before use. Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht type III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, the UK, and the US. Initial type-III DCD liver offers were correlated with accepted, recovered and implanted livers. A total number of 34,269 DCD livers were offered, resulting in 9,780 liver transplants (28.5%). The discard rates were highest in the UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g. between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, we observed large differences in the use of various machine perfusion techniques, as well as in graft and donor risk factors. For example, the median donor age and functional donor warm ischemia time were highest in Italy, e.g. >40 min, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in 5-year graft survival rates, which ranged between 60-82% in this analysis. Overall, DCD liver discard rates across the eight countries were high, although this primarily reflects the situation in the Netherlands, the UK and the US. Countries where in situ and ex situ machine perfusion strategies were used routinely had better DCD utilization rates without compromised outcomes. A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5% but varies significantly between 18.9% and 74.2%. For example, the median DCD-III liver utilization in five countries, e.g. Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, 1- and 5-year graft survival rates remain fairly similar among all participating countries. A highly varying experience with modern machine perfusion technology was observed. In situ and ex situ liver perfusion concepts, and application of assessment tools for type-III DCD livers before transplantation, may be a key explanation for the observed differences in DCD-III utilization.

1 September 2015 in Anesthesiology
Verified
Journal Article
Open access
PDF file
MCMassimo Cressoni
Massimo Cressoni
CCChiara Chiurazzi
Chiara Chiurazzi
MGMiriam Gotti
Miriam Gotti
MAMartina Amini
Martina Amini
MBMatteo Brioni
Matteo Brioni
LGLuciano Gattinoni
Luciano Gattinoni
Ventilator-induced lung injury detected as an increased density on computed tomography scan, first occurred at inhomogeneous interfaces, including at the visceral pleura and the subpleural alveolar walls in anesthetized piglets ventilated with a tidal volume/end-expiratory lung volume more than 2.5. New lung densities were found within 8 h of the ventilation, and their number increased exponentially up to 15 h. Lung elastance and gas exchange deteriorated significantly after 18 h, and full lung edema developed after 20 h. Supplemental Digital Content is available in the text. Background: During mechanical ventilation, stress and strain may be locally multiplied in an inhomogeneous lung. The authors investigated whether, in healthy lungs, during high pressure/volume ventilation, injury begins at the interface of naturally inhomogeneous structures as visceral pleura, bronchi, vessels, and alveoli. The authors wished also to characterize the nature of the lesions (collapse vs. consolidation). Methods: Twelve piglets were ventilated with strain greater than 2.5 (tidal volume/end-expiratory lung volume) until whole lung edema developed. At least every 3 h, the authors acquired end-expiratory/end-inspiratory computed tomography scans to identify the site and the number of new lesions. Lung inhomogeneities and recruitability were quantified. Results: The first new densities developed after 8.4 ± 6.3 h (mean ± SD), and their number increased exponentially up to 15 ± 12 h. Afterward, they merged into full lung edema. A median of 61% (interquartile range, 57 to 76) of the lesions appeared in subpleural regions, 19% (interquartile range, 11 to 23) were peribronchial, and 19% (interquartile range, 6 to 25) were parenchymal (P < 0.0001). All the new densities were fully recruitable. Lung elastance and gas exchange deteriorated significantly after 18 ± 11 h, whereas lung edema developed after 20 ± 11 h. Conclusions: Most of the computed tomography scan new densities developed in nonhomogeneous lung regions. The damage in this model was primarily located in the interstitial space, causing alveolar collapse and consequent high recruitability.

5 April 2022 in American Journal of Transplantation
Verified
Journal Article
Open access
IBIsabel M.A. Brüggenwirth
Isabel M.A. Brüggenwirth
MMMatteo Mueller
Matteo Mueller
VLVeerle A. Lantinga
Veerle A. Lantinga
SCStefania Camagni
Stefania Camagni
RCRiccardo De Carlis
Riccardo De Carlis
VMVincent E. de Meijer
Vincent E. de Meijer
A short period (1–2 h) of hypothermic oxygenated machine perfusion (HOPE) after static cold storage is safe and reduces ischemia‐reperfusion injury‐related complications after liver transplantation. Machine perfusion time is occasionally prolonged for logistical reasons, but it is unknown if prolonged HOPE is safe and compromises outcomes. We conducted a multicenter, observational cohort study of patients transplanted with a liver preserved by prolonged (≥4 h) HOPE. Postoperative biochemistry, complications, and survival were evaluated. The cohort included 93 recipients from 12 European transplant centers between 2014–2021. The most common reason to prolong HOPE was the lack of an available operating room to start the transplant procedure. Grafts underwent HOPE for a median (range) of 4:42 h (4:00–8:35 h) with a total preservation time of 10:50 h (5:50–20:50 h). Postoperative peak ALT was 675 IU/L (interquartile range 419–1378 IU/L). The incidence of postoperative complications was low, and 1‐year graft and patient survival were 94% and 88%, respectively. To conclude, good outcomes are achieved after transplantation of donor livers preserved with prolonged (median 4:42 h) HOPE, leading to a total preservation time of almost 21 h. These results suggest that simple, end‐ischemic HOPE may be utilized for safe extension of the preservation time to ease transplantation logistics.

15 December 2015 in Intensive Care Medicine Experimental
Verified
Journal Article
Open access
PDF file
APAlessandro Protti
Alessandro Protti
DADavide T. Andreis
Davide T. Andreis
MMMarta Milesi
Marta Milesi
GIGiacomo E. Iapichino
Giacomo E. Iapichino
MMMassimo Monti
Massimo Monti
LGLuciano Gattinoni
Luciano Gattinoni
High tidal volume can cause ventilator-induced lung injury (VILI), but positive end-expiratory pressure (PEEP) is thought to be protective. We aimed to find the volumetric VILI threshold and see whether PEEP is protective per se or indirectly. In 76 pigs (22 ± 2 kg), we examined the lower and upper limits (30.9–59.7 mL/kg) of inspiratory capacity by computed tomography (CT) scan at 45 cmH2O pressure. The pigs underwent a 54-h mechanical ventilation with a global strain ((tidal volume (dynamic) + PEEP volume (static))/functional residual capacity) from 0.45 to 5.56. The dynamic strain ranged from 18 to 100 % of global strain. Twenty-nine pigs were ventilated with end-inspiratory volumes below the lower limit of inspiratory capacity (group “Below”), 38 within (group “Within”), and 9 above (group “Above”). VILI was defined as death and/or increased lung weight. “Below” pigs did not develop VILI; “Within” pigs developed lung edema, and 52 % died before the end of the experiment. The amount of edema was significantly related to dynamic strain (edema 188–153 × dynamic strain, R 2 = 0.48, p < 0.0001). In the “Above” group, 66 % of the pigs rapidly died but lung weight did not increase significantly. In pigs ventilated with similar tidal volume adding PEEP significantly increased mortality. The threshold for VILI is the lower limit of inspiratory capacity. Below this threshold, VILI does not occur. Within these limits, severe/lethal VILI occurs depending on the dynamic component. Above inspiratory capacity stress at rupture may occur. In healthy lungs, PEEP is protective only if associated with a reduced tidal volume; otherwise, it has no effect or is harmful.