Janina Eden

Janina Eden

Auto-generated profile, based on publicly available information

Janina Eden

Department of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in Journal of Hepatology
Verified
Journal Article
Open access
ASAndrea Schlegel
Andrea Schlegel
MMMatteo Mueller
Matteo Mueller
XMXavier Muller
Xavier Muller
JEJanina Eden
Janina Eden
RPRebecca Panconesi
Rebecca Panconesi
PDPhilipp Dutkowski
Philipp Dutkowski
Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.

4 February 2023 in Journal of Hepatology
Verified
Journal Article
Open access
JEJanina Eden
Janina Eden
RSRichard Xavier Sousa Da Silva
Richard Xavier Sousa Da Silva
MCMiriam Cortes-Cerisuelo
Miriam Cortes-Cerisuelo
KCKristopher Croome
Kristopher Croome
RCRiccardo De Carlis
Riccardo De Carlis
PDPhilipp Dutkowski
Philipp Dutkowski
Liver graft utilization rates are a hot topic due to the worldwide organ shortage and the increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially enable the assessment of livers before use. Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht type III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, the UK, and the US. Initial type-III DCD liver offers were correlated with accepted, recovered and implanted livers. A total number of 34,269 DCD livers were offered, resulting in 9,780 liver transplants (28.5%). The discard rates were highest in the UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g. between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, we observed large differences in the use of various machine perfusion techniques, as well as in graft and donor risk factors. For example, the median donor age and functional donor warm ischemia time were highest in Italy, e.g. >40 min, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in 5-year graft survival rates, which ranged between 60-82% in this analysis. Overall, DCD liver discard rates across the eight countries were high, although this primarily reflects the situation in the Netherlands, the UK and the US. Countries where in situ and ex situ machine perfusion strategies were used routinely had better DCD utilization rates without compromised outcomes. A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5% but varies significantly between 18.9% and 74.2%. For example, the median DCD-III liver utilization in five countries, e.g. Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, 1- and 5-year graft survival rates remain fairly similar among all participating countries. A highly varying experience with modern machine perfusion technology was observed. In situ and ex situ liver perfusion concepts, and application of assessment tools for type-III DCD livers before transplantation, may be a key explanation for the observed differences in DCD-III utilization.

5 April 2022 in American Journal of Transplantation
Verified
Journal Article
Open access
IBIsabel M.A. Brüggenwirth
Isabel M.A. Brüggenwirth
MMMatteo Mueller
Matteo Mueller
VLVeerle A. Lantinga
Veerle A. Lantinga
SCStefania Camagni
Stefania Camagni
RCRiccardo De Carlis
Riccardo De Carlis
VMVincent E. de Meijer
Vincent E. de Meijer
A short period (1–2 h) of hypothermic oxygenated machine perfusion (HOPE) after static cold storage is safe and reduces ischemia‐reperfusion injury‐related complications after liver transplantation. Machine perfusion time is occasionally prolonged for logistical reasons, but it is unknown if prolonged HOPE is safe and compromises outcomes. We conducted a multicenter, observational cohort study of patients transplanted with a liver preserved by prolonged (≥4 h) HOPE. Postoperative biochemistry, complications, and survival were evaluated. The cohort included 93 recipients from 12 European transplant centers between 2014–2021. The most common reason to prolong HOPE was the lack of an available operating room to start the transplant procedure. Grafts underwent HOPE for a median (range) of 4:42 h (4:00–8:35 h) with a total preservation time of 10:50 h (5:50–20:50 h). Postoperative peak ALT was 675 IU/L (interquartile range 419–1378 IU/L). The incidence of postoperative complications was low, and 1‐year graft and patient survival were 94% and 88%, respectively. To conclude, good outcomes are achieved after transplantation of donor livers preserved with prolonged (median 4:42 h) HOPE, leading to a total preservation time of almost 21 h. These results suggest that simple, end‐ischemic HOPE may be utilized for safe extension of the preservation time to ease transplantation logistics.

7 September 2024 in Journal of Hepatology
Verified
Journal Article
Closed access
JEJahnina Eden
Jahnina Eden
ATAdam M. Thorne
Adam M. Thorne
SBSilke Bodewes
Silke Bodewes
DPDamiano Patrono
Damiano Patrono
DRDorotea Roggio
Dorotea Roggio
PDPhilipp Dutkowski
Philipp Dutkowski

3 July 2024 in Journal of Hepatology
Verified
Journal Article
Open access
JEJanina Eden
Janina Eden
IBIsabel M.A. Brüggenwirth
Isabel M.A. Brüggenwirth
GBGabriela Berlakovich
Gabriela Berlakovich
BBBettina M. Buchholz
Bettina M. Buchholz
FBFlorin Botea
Florin Botea
VMVincent E. de Meijer
Vincent E. de Meijer
Despite strong evidence for improved preservation of donor livers by machine perfusion, longer post-transplant follow-up data are urgently needed in an unselected patient population. We aimed to assess long-term outcomes after transplantation of hypothermic oxygenated machine perfusion (HOPE)-treated donor livers based on real-world data (i.e., IDEAL-D stage 4). In this international, multicentre, observational cohort study, we collected data from adult recipients of HOPE-treated livers transplanted between January 2012 and December 2021. Analyses were stratified by donation after brain death (DBD) and donation after circulatory death (DCD), sub-divided by their respective risk categories. The primary outcome was death-censored graft survival. Secondary outcomes included the incidence of primary non-function (PNF) and ischaemic cholangiopathy (IC). We report on 1,202 liver transplantations (64% DBD) performed at 22 European centres. For DBD, a total number of 99 benchmark (8%), 176 standard (15%), and 493 extended-criteria (41%) cases were included. For DCD, 117 transplants were classified as low risk (10%), 186 as high risk (16%), and 131 as futile (11%), with significant risk profile variations among centres. Actuarial 1-, 3-, and 5-year death-censored graft survival rates for DBD and DCD livers were 95%, 92%, and 91%, vs. 92%, 87%, and 81%, respectively (log-rank p = 0.003). Within DBD and DCD strata, death-censored graft survival was similar among risk groups (log-rank p = 0.26, p = 0.99). Graft loss due to PNF or IC was 2.3% and 0.4% (DBD), and 5% and 4.1% (DCD). This study shows excellent 5-year survival after transplantation of HOPE-treated DBD and DCD livers with low rates of graft loss due to PNF or IC, irrespective of their individual risk profile. HOPE treatment has now reached IDEAL-D stage 4, which further supports its implementation in routine clinical practice. ClinicalTrials.gov Identifier: NCT05520320. This study demonstrates the excellent long-term performance of hypothermic oxygenated machine perfusion (HOPE) treatment of donation after circulatory and donation after brain death liver grafts irrespective of their individual risk profile in a real-world setting, outside the evaluation of randomised-controlled trials. While previous studies have established safety, feasibility, and efficacy against the current standard, according to the IDEAL-D evaluation framework, HOPE treatment has now reached the final IDEAL-D stage 4, which further supports its implementation in routine clinical practice.

31 October 2023 in EBioMedicine
Verified
Journal Article
Open access
JEJanina Eden
Janina Eden
EBEva Breuer
Eva Breuer
DBDominique Birrer
Dominique Birrer
MMMatteo Mueller
Matteo Mueller
MPMatthias Pfister
Matthias Pfister
PDPhilipp Dutkowski
Philipp Dutkowski
To report on a concept of liver assessment during ex situ hypothermic oxygenated perfusion (HOPE) and its significant impact on liver utilization. An analysis of prospectively collected data on donation after circulatory death (DCD) livers, treated by HOPE at our institution, during a 11-year period between January 2012 and December 2022. Four hundred and fifteen DCD Maastricht III livers were offered during the study period in Switzerland, resulting in 249 liver transplants. Of those, we performed 158 DCD III liver transplants at our institution, with 1-year patient survival and death censored graft survival (death with functioning graft) of 87 and 89%, respectively, thus comparable to benchmark graft survivals of ideal DBD and DCD liver transplants (89% and 86%). Correspondingly, graft loss for primary non-function or cholangiopathy was overall low, i.e., 7/158 (4.4%) and 11/158 (6.9%), despite more than 82% of DCD liver grafts ranked high (6-10 points) or futile risk (>10 points) according to the UK-DCD score. Consistently, death censored graft survival was not different between low-, high-risk or futile DCD III livers. The key behind these achievements was the careful development and implementation of a routine perfusate assessment of mitochondrial biomarkers for injury and function, i.e., release of flavin mononucleotide from complex I, perfusate NADH, and mitochondrial CO2 production during HOPE, allowing a more objective interpretation of liver quality on a subcellular level, compared to donor derived data. HOPE after cold storage is a highly suitable and easy to perform perfusion approach, which allows reliable liver graft assessment, enabling surgeons to make a fact based decision on whether or not to implant the organ. HOPE-treatment should be combined with viability assessment particularly when used for high-risk organs, including DCD livers or organs with relevant steatosis. This study was supported by the Swiss National Foundation (SNF) grant 320030_189055/1 to PD.