Philipp Dutkowski

Prof. Philipp Dutkowski


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in EBioMedicine
Verified
Journal Article
Open access
ASAndrea Schlegel
Andrea Schlegel
XMXavier Muller
Xavier Muller
MMMatteo Mueller
Matteo Mueller
ASAnna Stepanova
Anna Stepanova
PKPhilipp Kron
Philipp Kron
PDPhilipp Dutkowski
Philipp Dutkowski
Mitochondrial succinate accumulation has been suggested as key event for ischemia reperfusion injury in mice. No specific data are however available on behavior of liver mitochondria during ex situ machine perfusion in clinical transplant models. We investigated mitochondrial metabolism of isolated perfused rat livers before transplantation. Livers were exposed to warm and cold ischemia to simulate donation after circulatory death (DCD) and organ transport. Subsequently, livers were perfused with oxygenated Belzer-MPS for 1h, at hypothermic or normothermic conditions. Various experiments were performed with supplemented succinate and/or mitochondrial inhibitors. The perfusate, liver tissues, and isolated mitochondria were analyzed by mass-spectroscopy and fluorimetry. Additionally, rat DCD livers were transplanted after 1h hypothermic or normothermic oxygenated perfusion. In parallel, perfusate samples were analysed during HOPE-treatment of human DCD livers before transplantation. Succinate exposure during rat liver perfusion triggered a dose-dependent release of mitochondrial Flavin-Mononucleotide (FMN) and NADH in perfusates under normothermic conditions. In contrast, perfusate FMN was 3-8 fold lower under hypothermic conditions, suggesting less mitochondrial injury during cold re-oxygenation compared to normothermic conditions. HOPE-treatment induced a mitochondrial reprogramming with uploading of the nucleotide pool and effective succinate metabolism. This resulted in a clear superiority after liver transplantation compared to normothermic perfusion. Finally, the degree of mitochondrial injury during HOPE of human DCD livers, quantified by perfusate FMN and NADH, was predictive for liver function. Mitochondrial injury determines outcome of transplanted rodent and human livers. Hypothermic oxygenated perfusion improves mitochondrial function, and allows viability assessment of liver grafts before implantation. detailed information can be found in Acknowledgments.

1 November 2019 in Annals of Surgery
Verified
Journal Article
Closed access
XMXavier Muller
Xavier Muller
ASAndrea Schlegel
Andrea Schlegel
PKPhilipp Kron
Philipp Kron
DEDilmurodjon Eshmuminov
Dilmurodjon Eshmuminov
MWMichael Würdinger
Michael Würdinger
PDPhilipp Dutkowski
Philipp Dutkowski
Objective: The aim of this study was to determine the predictive value of machine perfusate analysis on graft outcome. Background: Ex situ machine perfusion (MP) is gaining increasing interest to potentially repair injured organs and to assess organ function. In the field of liver transplantation, however, no studies exist on reliable prediction of graft function during MP. Methods: We have used hypothermic oxygenated perfusion (HOPE) for donation after circulatory death (DCD) or extended criteria donation after brain death (DBD) human liver grafts during the last 7 years. Our series includes 100 HOPE-treated liver-transplanted patients with an overall tumor-censored 5-year graft survival of 89%. We monitored 54 livers during HOPE in terms of fluorometric analysis of released mitochondrial flavin (flavin mononucleotide, FMN) in the machine perfusate. Results: Real-time optical measurement of mitochondrial FMN release in machine perfusates of livers disclosed a strong correlation with lactate clearance and coagulation factors at day 1 and 2 after transplantation. Receiver-operating characteristic curve analysis revealed an area under the curve (AUROC) of 0.79 [95% confidence interval (CI), 0.62–0.97] for severe allograft dysfunction and for early graft loss (AUROC 0.93, 95% CI, 0.84–1.0). Conclusions: Assessment of flavin, a marker of mitochondrial complex I injury, in the perfusate provides a fast prediction of liver graft function and loss during ex situ MP before implantation. This finding may have high clinical relevance, as liver grafts from extended DBD or DCD donors carry considerable risks for recipients. On-line estimation of outcome before implantation would therefore substantially increase safe utilization of liver grafts.

19 January 2023 in Journal of Hepatology
Verified
Journal Article
Open access
ASAndrea Schlegel
Andrea Schlegel
MMMatteo Mueller
Matteo Mueller
XMXavier Muller
Xavier Muller
JEJanina Eden
Janina Eden
RPRebecca Panconesi
Rebecca Panconesi
PDPhilipp Dutkowski
Philipp Dutkowski
Machine perfusion is a novel method intended to optimize livers before transplantation. However, its effect on morbidity within a 1-year period after transplantation has remained unclear. In this multicenter controlled trial, we randomly assigned livers donated after brain death (DBD) for liver transplantation (LT). Livers were either conventionally cold stored (control group), or cold stored and subsequently treated by 1-2 h hypothermic oxygenated perfusion (HOPE) before implantation (HOPE group). The primary endpoint was the occurrence of at least one post-transplant complication per patient, graded by the Clavien score of ≥III, within 1-year after LT. The comprehensive complication index (CCI), laboratory parameters, as well as duration of hospital and intensive care unit stay, graft survival, patient survival, and biliary complications served as secondary endpoints. Between April 2015 and August 2019, we randomized 177 livers, resulting in 170 liver transplantations (85 in the HOPE group and 85 in the control group). The number of patients with at least one Clavien ≥III complication was 46/85 (54.1%) in the control group and 44/85 (51.8%) in the HOPE group (odds ratio 0.91; 95% CI 0.50-1.66; p = 0.76). Secondary endpoints were also not significantly different between groups. A post hoc analysis revealed that liver-related Clavien ≥IIIb complications occurred less frequently in the HOPE group compared to the control group (risk ratio 0.26; 95% CI 0.07-0.77; p = 0.027). Likewise, graft failure due to liver-related complications did not occur in the HOPE group, but occurred in 7% (6 of 85) of the control group (log-rank test, p = 0.004, Gray test, p = 0.015). HOPE after cold storage of DBD livers resulted in similar proportions of patients with at least one Clavien ≥III complication compared to controls. Exploratory findings suggest that HOPE decreases the risk of severe liver graft-related events. This randomized controlled phase III trial is the first to investigate the impact of hypothermic oxygenated perfusion (HOPE) on cumulative complications within a 12-month period after liver transplantation. Compared to conventional cold storage, HOPE did not have a significant effect on the number of patients with at least one Clavien ≥III complication. However, we believe that HOPE may have a beneficial effect on the quantity of complications per patient, based on its application leading to fewer severe liver graft-related complications, and to a lower risk of liver-related graft loss. The HOPE approach can be applied easily after organ transport during recipient hepatectomy. This appears fundamental for wide acceptance since concurring perfusion technologies need either perfusion at donor sites or continuous perfusion during organ transport, which are much costlier and more laborious. We conclude therefore that the post hoc findings of this trial should be further validated in future studies.

1 November 2009 in Annals of Surgery
Verified
Journal Article
Closed access
OROlivier de Rougemont
Olivier de Rougemont
SBStefan Breitenstein
Stefan Breitenstein
BLBoris Leskosek
Boris Leskosek
AWAchim Weber
Achim Weber
RGRolf Graf
Rolf Graf
PDPhilipp Dutkowski
Philipp Dutkowski
Objectives: To test, in a large animal model, the efficacy of machine perfusion to rescue livers after prolonged ischemic injury. Background: Our group previously showed in various rodent models the benefit of endischemic hypothermic oxygenated perfusion (HOPE) in protecting liver injury from donation after cardiac death (DCD). Convincing results are needed in large animal models before application in human. Methods: A new model of DCD liver transplantation in large pigs was developed. Pig livers (1300 ± 210 g each) were harvested 60 minutes after induction of cardiac death (respirator withdrawal). In situ flush and organ procurement were initiated without heparin pretreatment. Then, livers were preserved for 7 hours in cold Celsior (DCD-group) prior to orthotopic transplantation (OLT). Some livers were treated by 1 hour HOPE prior to implantation (HOPE-group). In a first step, animals were kept under anesthesia for 6 hours after orthotopic transplantation. Endpoints included serum (AST) and tissue (ATP, glutathione) markers of injury, bile flow, and histology. In a second step, survival experiments were performed. Results: Livers from the DCD group displayed diffuse necrosis of hepatocytes, increased adhesion of platelets, high AST release, absence of bile flow, depletion of glutathione, and ATP. In contrast, livers treated with HOPE showed dramatic reduction of necrosis, platelet adhesion, while bile flow, ATP recovery and glutathione were improved. Importantly, untreated DCD livers caused graft failure and death of all recipients within 6 hours of reperfusion, whereas HOPE treated DCD livers remained hemodynamically stable. Conclusions: This is the first study in a reliable large animal transplant model demonstrating the efficacy of a simple cold oxygenated machine perfusion system to rescue, otherwise lethal, ischemic injured DCD liver grafts.

1 January 2018 in Journal of Hepatology
Verified
Journal Article
Closed access
PKPhilipp Kron
Philipp Kron
ASAndrea Schlegel
Andrea Schlegel
LMLeandro Mancina
Leandro Mancina
PCPierre-Alain Clavien
Pierre-Alain Clavien
PDPhilipp Dutkowski
Philipp Dutkowski

4 February 2023 in Journal of Hepatology
Verified
Journal Article
Open access
JEJanina Eden
Janina Eden
RSRichard Xavier Sousa Da Silva
Richard Xavier Sousa Da Silva
MCMiriam Cortes-Cerisuelo
Miriam Cortes-Cerisuelo
KCKristopher Croome
Kristopher Croome
RCRiccardo De Carlis
Riccardo De Carlis
PDPhilipp Dutkowski
Philipp Dutkowski
Liver graft utilization rates are a hot topic due to the worldwide organ shortage and the increasing number of transplant candidates on waiting lists. Liver perfusion techniques have been introduced in several countries, and may help to increase the organ supply, as they potentially enable the assessment of livers before use. Liver offers were counted from donation after circulatory death (DCD) donors (Maastricht type III) arising during the past decade in eight countries, including Belgium, France, Italy, the Netherlands, Spain, Switzerland, the UK, and the US. Initial type-III DCD liver offers were correlated with accepted, recovered and implanted livers. A total number of 34,269 DCD livers were offered, resulting in 9,780 liver transplants (28.5%). The discard rates were highest in the UK and US, ranging between 70 and 80%. In contrast, much lower DCD liver discard rates, e.g. between 30-40%, were found in Belgium, France, Italy, Spain and Switzerland. In addition, we observed large differences in the use of various machine perfusion techniques, as well as in graft and donor risk factors. For example, the median donor age and functional donor warm ischemia time were highest in Italy, e.g. >40 min, followed by Switzerland, France, and the Netherlands. Importantly, such varying risk profiles of accepted DCD livers between countries did not translate into large differences in 5-year graft survival rates, which ranged between 60-82% in this analysis. Overall, DCD liver discard rates across the eight countries were high, although this primarily reflects the situation in the Netherlands, the UK and the US. Countries where in situ and ex situ machine perfusion strategies were used routinely had better DCD utilization rates without compromised outcomes. A significant number of Maastricht type III DCD livers are discarded across Europe and North America today. The overall utilization rate among eight Western countries is 28.5% but varies significantly between 18.9% and 74.2%. For example, the median DCD-III liver utilization in five countries, e.g. Belgium, France, Italy, Switzerland, and Spain is 65%, in contrast to 24% in the Netherlands, UK and US. Despite this, and despite different rules and strategies for organ acceptance and preservation, 1- and 5-year graft survival rates remain fairly similar among all participating countries. A highly varying experience with modern machine perfusion technology was observed. In situ and ex situ liver perfusion concepts, and application of assessment tools for type-III DCD livers before transplantation, may be a key explanation for the observed differences in DCD-III utilization.