A simple flow system employing a reversible-flow syringe pump was employed to synthesize uniform micron-size particles of chitosan-Cu(II) (CS-Cu(II)) catalyst. A solution of chitosan and Cu(II) salt was drawn into a holding coil via a 3-way switching valve and then slowly pumped to drip into an alkaline solution to form of hydrogel droplets. The droplets were washed and dried to obtain the catalyst particles. Manual addition into the alkaline solution or employment of flow system with a vibrating rod, through which the end of the flow line is inserted, was investigated for comparison. A sampling method was selected to obtain representative samples of the population of the synthesized particles for size measurement using optical microscopy. The mean sizes of the particles were 880 ± 70 µm, 780 ± 20 µm, and 180 ± 30 µm for the manual and flow methods, without and with the vibrating rod, respectively. Performance of the flow methods, in terms of rate of droplet production and particle size distribution, are discussed. Samples of 180 µm size CS-Cu(II) particles were tested for catalytic reduction of 0.5 mM p-nitrophenol to p-aminophenol by 100-fold excess borohydride. The conversion was 98% after 20 min, whereas without the catalyst there was only 14% conversion.
This work presents, for the first time, a novel cross injection analysis (CIA) system for the simultaneous multi-determination of key biomarkers associated with diabetic nephropathy—namely, albumin, creatinine, and glucose—within a single analytical run. Unlike conventional flow-based techniques that rely on sequential measurements, the proposed CIA platform integrates multiple analytical pathways into a unified design, enabling one-shot multi-analyte analysis without the need for complex separation units or injection valves. The system employs peristaltic pumps and a rectangular platform with orthogonal flow channels, allowing concurrent aspiration and efficient transport of reaction products to compact detectors. Albumin determination was based on ion-association with tetrabromophenolphthalein ethyl ester. Creatinine was measured using the Jaffé reaction. Glucose was colorimetrically detected via its reaction with 3,5-dinitrosalicylic acid. The developed CIA provides enhanced sensitivity through its pre-mixing effect, enabling reliable quantification of trace analytes. Excellent analytical performance was achieved, including wide linear ranges (r2 > 0.99), good precision (RSD < 7%), and rapid analysis (5 min). The method was validated against established reference methods, showing no significant differences, and successfully applied to urine with satisfactory recoveries (84.8–107.3%). Importantly, the proposed system adheres to green chemistry by minimizing reagent consumption and waste generation, offering a sustainable approach for multi-parameter clinical analysis.