Nathawut Choengchan

Dr. Nathawut Choengchan


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 April 2024 in Microchemical Journal
Verified
Journal Article
Closed access
KTKanyapak Thangjitsirisin
Kanyapak Thangjitsirisin
PSPanpailin Seeharaj
Panpailin Seeharaj
NCNathawut Choengchan
Nathawut Choengchan

30 January 2023 in Molecules
Verified
Journal Article
Open access
PDF file
TSThachkorn Somboonsuk
Thachkorn Somboonsuk
PSPhoonthawee Saetear
Phoonthawee Saetear
TMThitirat Mantim
Thitirat Mantim
NRNuanlaor Ratanawimarnwong
Nuanlaor Ratanawimarnwong
PWPrapin Wilairat
Prapin Wilairat
NCNathawut Choengchan
Nathawut Choengchan
This work presents the use of a transparent ‘Cross Injection Analysis’ (CIA) platform as a flow system for chemiluminescence (CL) measurements. The CL-CIA flow device incorporates introduction channels for samples and reagents, and the reaction and detection channels are in one acrylic unit. A photomultiplier tube placed above the reaction channel detects the emitted luminescence. The system was applied to the analysis of (i) Co(II) via the Co(II)-catalyzed H2O2-luminol reaction and (ii) paracetamol via its inhibitory effect on the catalytic activity of Fe(CN)63− on the H2O2-luminol reaction. A linear calibration was obtained for Co(II) in the range of 0.002 to 0.025 mg L−1 Co(II) (r2 = 0.9977) for the determination of Co(II) in water samples. The linear calibration obtained for the paracetamol was 10 to 200 mg L−1 (r2 = 0.9906) for the determination of pharmaceutical products. The sample throughput was 60 samples h−1. The precision was ≤4.2% RSD. The consumption of the samples and reagents was ca. 170 µL per analysis cycle.

1 August 2016 in Journal of Food Composition and Analysis
Verified
Journal Article
Closed access
AJAmornrassamee Jinnarak
Amornrassamee Jinnarak
PAPattarapon Anantavichian
Pattarapon Anantavichian
AIApichai Intanin
Apichai Intanin
SFSuchada Fungladda
Suchada Fungladda
NCNathawut Choengchan
Nathawut Choengchan
STSaowapak Teerasong
Saowapak Teerasong

1 September 2013 in Journal of Nanoelectronics and Optoelectronics
Verified
Journal Article
Closed access
STSaowapak Teerasong
Saowapak Teerasong
TSThitaporn Sonsa-Ard
Thitaporn Sonsa-Ard
CVChavin Vimolkanjana
Chavin Vimolkanjana
NCNathawut Choengchan
Nathawut Choengchan
ACApiwat Chompoosor
Apiwat Chompoosor
DNDuangjai Nacapricha
Duangjai Nacapricha

10 November 2023 in CURRENT APPLIED SCIENCE AND TECHNOLOGY
Verified
Journal Article
Open access
PDF file
WWWannakan Wisaichon
Wannakan Wisaichon
NCNathawut Choengchan
Nathawut Choengchan
WPWiboon Praditweangkum
Wiboon Praditweangkum
This work describes a simple method for the simultaneous measurement of urinary albumin, creatinine and uric acid using a standard addition approach on a microfluidic paper-based analytical device (µPAD). Hydrophobic barrier of the µPAD was created by stamping indelible ink onto a filter paper. The µPAD was designed with a flower-liked configuration. After aliquoting urine to a central sample zone, the sample flowed to ten surrounding channels, namely “the inner channels”, where the blank (water) or standard solutions had been added. The inner channels were connected to circular reagent zones where reagents had been immobilized. Tetrabromophenolphthalein ethyl ester, alkaline picrate, and a mixed solution of ferric chloride and ferric cyanide were used as the chromogenic reagents for the colorimetric detections of albumin, creatinine, and uric acid, respectively. Each reagent zone was linked with a circular detection zone through a second channel, namely “the outer channels”. The blue-, orange- and greenish-blue colored products were observed in the detection zones for the measurement of albumin, creatinine, and uric acid, correspondingly. A digital image of the µPAD was captured with a mobile phone. The color intensities were evaluated by ImageJTM and were employed for the quantitative analyses. The standard addition calibrations were found to be linear (r2 > 0.99) for the spiked analyte concentrations up to 100 mg L-1 albumin, 1000 mg L-1 creatinine, and 50 mg dL-1 uric acid. The paper platform provided high precision (RSD < 5 %) and good analytical recovery (91.8-109.7 %). Under paired t-test, the results obtained by the developed µPAD and the validating methods were not significantly different at 95 % confidence (albumin: tstat = -0.130, tcri = 3.182, creatinine: tstat = -0.133, tcri = 3.182, and uric acid: tstat = 1.119, tcri = 3.182).

25 April 2025 in Talanta Open
Verified
Journal Article
Open access
STSurachet Thongchan
Surachet Thongchan
PSPunyapat Sookpotarom
Punyapat Sookpotarom
WPWiboon Praditweangkum
Wiboon Praditweangkum
PTPanumart Thongyoo
Panumart Thongyoo
NSNeso Sojic
Neso Sojic
NCNathawut Choengchan
Nathawut Choengchan