Ilgin Ari

Dr. Ilgin Ari


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 March 2024 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
IAIlgin Ari
Ilgin Ari
SASelen Adiloglu
Selen Adiloglu
AAAlper Aktas
Alper Aktas
GYGöknur Topaloglu Yasan
Göknur Topaloglu Yasan
EUEcem Usman
Ecem Usman
SASena Aksoy
Sena Aksoy

24 September 2024 in Journal of Prosthodontics
Verified
Journal Article
Open access
IAIlgin Ari
Ilgin Ari
GAGülin Acar
Gülin Acar
ETEmre Tosun
Emre Tosun
MMMehmet Muhtaroğulları
Mehmet Muhtaroğulları
Purpose: To assess the biomechanical advantages of combining zygoma and partial subperiosteal implants for maxillary reconstruction in severely atrophic maxillae, offering potential solutions to the challenges posed by traditional reconstruction methods.Material and Methods: A finite element analysis used a craniofacial model simulating a totally resected maxilla. Four treatment scenarios (SCs) were evaluated: SC‐1, the quad zygoma approach; SC‐2, two zygoma implants (ZIs) and a one‐piece subperiosteal implant (SI); SC‐3, two ZI and a two‐piece SI; and SC‐4, four ZI and a one‐piece SI. Stress distributions on bone, implants, abutments, and metal frameworks were compared under occlusal forces.Results: For the simulated bone regions under vertical and oblique forces, SC‐4 values were higher than SC‐1, while SC‐2 and SC‐3 values were comparable for pmax and pmin. In addition, SC‐2 and SC‐3 values were lower than those of SC‐1 and SC‐4. The most balanced von Mises stress values on the ZIsand were observed in SC‐3 under vertical and oblique forces. Furthermore, lower von Mises stress values on the abutments were seen in SC‐3 under oblique and vertical forces. Although the lower von Mises stress values on the metal frameworks at the lateral incisor and first premolar side were seen in SC‐3, lower von Mises values were observed in SC‐4 in the first molar region.Conclusions: Overall, this study suggests that combining zygoma and partial subperiosteal implants may be a promising approach for reconstructing severely atrophic maxillae. These implants may offer improved biomechanical properties compared to ZIs alone.

30 April 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
İBİpek Dilara Baş
İpek Dilara Baş
ETEmre Tosun
Emre Tosun
IAIlgin Ari
Ilgin Ari
GAGülin Acar
Gülin Acar
This study aimed to assess the stress distributions at different treatment options in edentulous and severely atrophic mandibula under trauma forces. In this study, four different treatment methods were applied to a severely atrophic edentulous mandibular model. In Model 1, inferior alveolar nerve lateralization was performed, followed by the placement of six implants. Model 2 utilized the all-on-four approach with implants placed. Model 3 used subperiosteal implants made of PEEK, while Model 4 used titanium subperiosteal implants. Each subperiosteal implant model included 14 osteosynthesis screws positioned in key areas of the mandible. 2000 Newton trauma force was applied anterior side of the mandibula. The maximum principal stress (Pmax), minimum principal stress (Pmin), and Von Mises (VMs) stress values are measured as MPa. In this study, Model 4 showed the highest Pmax in the symphysis region, while the other models had similar values. The mandibular condyle exhibited the highest Pmax in Model 1 and the lowest in Model 2. The Pmin values were comparable across all models in the symphysis region. Regarding VMs stress values, balanced stress was observed in the metal frameworks of all models. Model 3 had the most balanced and lowest VMs stress in abutments and abutment screws, while Model 4 had the highest. This FEA study found that both the all-on-4 and PEEK subperiosteal implants are more resistant under trauma forces compared to titanium subperiosteal implants and the 6-implant IANL approach. The PEEK subperiosteal implant offers a less invasive treatment option for fractured mandibles.

15 April 2025 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
IAIlgin Ari
Ilgin Ari
GAGülin Acar
Gülin Acar

30 June 2025 in Journal of the Korean Association of Oral and Maxillofacial Surgeons
Verified
Journal Article
Open access
PDF file
IAIlgin Ari
Ilgin Ari
EUEcem Usman
Ecem Usman
SASelen Adiloğlu
Selen Adiloğlu
AAAlper Aktaş
Alper Aktaş
Ilgin Ari, Ecem Usman, Selen Adiloğlu, Alper Aktaş. JKAOMS 2025;51:151-60. https://doi.org/10.5125/jkaoms.2025.51.3.151

26 January 2026 in Current Research in Dental Sciences
Verified
Journal Article
Open access
PDF file
IAIlgin Ari
Ilgin Ari
SASelen Adiloğlu
Selen Adiloğlu
AAAlper Aktaş
Alper Aktaş
AKAhmet Emin Kızılkaya
Ahmet Emin Kızılkaya
Objective: The aim of this study was to investigate and compare the treatment methods of large size oroantral defects (OADs) and their clinical outcomes. Methods: Patients referred our clinic between 2017 and 2023 suffering from oroantral fistula (OAF) and cases of oroantral communication (OAC) larger than 5 mm during oral procedures were included in the study. The size, type, and cause of OAD; treatment method; and the patient’s demographic data were recorded. Visual analogue scale (VAS), analgesic requirement, edema, and mouth opening measurements were obtained from preoperative and postoperative records at 3, 7, and 10 days after surgery. Results: 23 patients (eight OAF and 15 OAC) was included in this study. Nine patients were treated with buccal advancement flap (BAF), ten with buccal fat pad (BFP) flap, and four with the press-fit technique. There were no problems with the healing process. One patient had a failed BFP and after 2 months, a second surgery was performed to fully cover the area. According to postoperative clinical outcomes, there was no significant difference between groups in the terms of VAS, analgesic requirement, edema, or trismus at any timepoint (P>.05). Although there was no significant difference observed between treatment groups, VAS scale and analgesic requirement was less with the press-fit methoid than BAF and BFP flap. Conclusion: BAF, BFP flaps, and press-fit methods are reliable and well-known techniques for OAD management, however, further clinical studies with larger sample sizes are needed to create a treatment algorithm for OAD.