Gülin Acar

Gülin Acar

Auto-generated profile, based on publicly available information

Gülin Acar

Department of Oral and Maxillofacial Surgery, Faculty of Dentistry, Hacettepe University, Fakülteler Neighborhood, Ankara, Türkiye

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2024 in Journal of Prosthodontics
Verified
Journal Article
Open access
IAIlgin Ari
Ilgin Ari
GAGülin Acar
Gülin Acar
ETEmre Tosun
Emre Tosun
MMMehmet Muhtaroğulları
Mehmet Muhtaroğulları
Purpose: To assess the biomechanical advantages of combining zygoma and partial subperiosteal implants for maxillary reconstruction in severely atrophic maxillae, offering potential solutions to the challenges posed by traditional reconstruction methods.Material and Methods: A finite element analysis used a craniofacial model simulating a totally resected maxilla. Four treatment scenarios (SCs) were evaluated: SC‐1, the quad zygoma approach; SC‐2, two zygoma implants (ZIs) and a one‐piece subperiosteal implant (SI); SC‐3, two ZI and a two‐piece SI; and SC‐4, four ZI and a one‐piece SI. Stress distributions on bone, implants, abutments, and metal frameworks were compared under occlusal forces.Results: For the simulated bone regions under vertical and oblique forces, SC‐4 values were higher than SC‐1, while SC‐2 and SC‐3 values were comparable for pmax and pmin. In addition, SC‐2 and SC‐3 values were lower than those of SC‐1 and SC‐4. The most balanced von Mises stress values on the ZIsand were observed in SC‐3 under vertical and oblique forces. Furthermore, lower von Mises stress values on the abutments were seen in SC‐3 under oblique and vertical forces. Although the lower von Mises stress values on the metal frameworks at the lateral incisor and first premolar side were seen in SC‐3, lower von Mises values were observed in SC‐4 in the first molar region.Conclusions: Overall, this study suggests that combining zygoma and partial subperiosteal implants may be a promising approach for reconstructing severely atrophic maxillae. These implants may offer improved biomechanical properties compared to ZIs alone.

30 April 2025 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
İBİpek Dilara Baş
İpek Dilara Baş
ETEmre Tosun
Emre Tosun
IAIlgin Ari
Ilgin Ari
GAGülin Acar
Gülin Acar
This study aimed to assess the stress distributions at different treatment options in edentulous and severely atrophic mandibula under trauma forces. In this study, four different treatment methods were applied to a severely atrophic edentulous mandibular model. In Model 1, inferior alveolar nerve lateralization was performed, followed by the placement of six implants. Model 2 utilized the all-on-four approach with implants placed. Model 3 used subperiosteal implants made of PEEK, while Model 4 used titanium subperiosteal implants. Each subperiosteal implant model included 14 osteosynthesis screws positioned in key areas of the mandible. 2000 Newton trauma force was applied anterior side of the mandibula. The maximum principal stress (Pmax), minimum principal stress (Pmin), and Von Mises (VMs) stress values are measured as MPa. In this study, Model 4 showed the highest Pmax in the symphysis region, while the other models had similar values. The mandibular condyle exhibited the highest Pmax in Model 1 and the lowest in Model 2. The Pmin values were comparable across all models in the symphysis region. Regarding VMs stress values, balanced stress was observed in the metal frameworks of all models. Model 3 had the most balanced and lowest VMs stress in abutments and abutment screws, while Model 4 had the highest. This FEA study found that both the all-on-4 and PEEK subperiosteal implants are more resistant under trauma forces compared to titanium subperiosteal implants and the 6-implant IANL approach. The PEEK subperiosteal implant offers a less invasive treatment option for fractured mandibles.

30 September 2024 in Journal of Dental Education
Verified
Journal Article
Closed access
GAGülin Acar
Gülin Acar
SASelen Adiloğlu
Selen Adiloğlu
AAAlper Aktaş
Alper Aktaş
IGIlkem Gökçe
Ilkem Gökçe

15 April 2025 in Journal of Stomatology Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
IAIlgin Ari
Ilgin Ari
GAGülin Acar
Gülin Acar

24 February 2025 in Journal of Cranio-Maxillofacial Surgery
Verified
Journal Article
Closed access
GAGülin Acar
Gülin Acar
SMSalih Eren Meral
Salih Eren Meral
HTHakan H. Tüz
Hakan H. Tüz

13 August 2024 in Journal of Prosthodontics
Verified
Journal Article
Open access
TÖTAHA ÖZER
TAHA ÖZER
GAGülin Acar
Gülin Acar
Purpose: The success rate of the implant treatment, including aesthetics and long‐term survival, relies heavily on preserving crestal peri‐implant bone, as it determines the stability and long‐term outcomes. This study aimed to demonstrate the stress differences in the crestal bone resulting from dental implant placement at various depths relative to the crestal bone level using finite element analysis. Materials and Methods: Three study models were prepared for implant placement at the crestal bone level (CL), 1 mm depth (SL‐1), and 2 mm depth (SL‐2). Implants were placed in the maxillary central incisor region of each model, and 100 N vertical and oblique forces were applied. The von Mises, maximum principal (tensile), and minimum principal (compressive) stresses were evaluated. Results: The CL model exhibited the highest stresses on the implant, abutment, and abutment screws under vertical and oblique forces. For maximum principal stress in the crestal bone under vertical force, the SL‐2, SL‐1, and CL models recorded values of 6.56, 6.26, and 5.77 MPa, respectively. Under oblique forces, stress values for SL‐1, SL‐2, and CL were 25.3, 24.91, and 23.76 MPa, respectively. The CL model consistently exhibited the lowest crestal bone stress at all loads and the highest stress values on the implant and its components. Moreover, considering the yield strengths of the materials, no mechanical or physiological complications were noted. Conclusions: Placing the implant at the crestal level or subcrestally beyond the cortical layer could potentially reduce stress and minimize crestal bone loss. However, further studies are warranted for confirmation.