19 November 2018 in Energies
Verified
Journal Article
Open access
PDF file
HAHammad Alnuman
Hammad Alnuman
DGDaniel Gladwin
Daniel Gladwin
MFMartin Foster
Martin Foster
Electrical modelling of rail tracks with multiple running trains is complex due to the difficulties in solving the power flow. The train positions, speed and acceleration are constantly varying resulting in a nonlinear system. In this work, a method is proposed for modelling DC electric railways to support power flow analysis of a simulated metro train service. The method exploits the MathWorks simulation tool Simscape, using it to model the mechanical and electrical characteristics of the rail track system. The model can be simulated to provide voltages at any position in the track and additionally, the voltages seen by any train. The model includes regenerative braking on trains, this is demonstrated to cause overvoltage in the feeding line if it is higher than the power demand of the other trains at that time. Braking resistors are used to protect the network from overvoltage by burning the excess energy. Through the implementation of Energy Storage Systems (ESSs), it will be possible to improve the energy efficiency and remove timetabling restrictions of electric railways by effectively controlling the rail track voltage. The paper proposes several methods to validate the model.

10 April 2023 in IEEE Access
Verified
Journal Article
Open access
HAHammad Alnuman
Hammad Alnuman
RHReyaz Hussan
Reyaz Hussan
SIShirazul Islam
Shirazul Islam
ADIL SARWARADIL SARWAR
ADIL SARWAR
EAEmad M. Ahmed
Emad M. Ahmed
Ammar ArmghanAmmar Armghan
Ammar Armghan
A switched-capacitor based 13-level inverter with high gain and reduced switch stress is presented in this article. The 13-level single-phase ac output voltage is achieved with a voltage gain of 6 by utilizing a single dc source, 14 switches, 3 capacitors and 1 diode in the proposed converter. Self-voltage balancing is achieved for different types of loads without the use of complicated control schemes or supplementary circuitry. The proposed topology can generate negative polarity without a back-end H-bridge. Consequently, voltage stresses across the switches are reduced. The voltage stress across the switches is limited to 4 times the input DC voltage. Included also is an analysis of power loss for several components of the proposed converter. A comparison is made with contemporary topologies that require a single dc source at the input in terms of several performance characteristics. Resistive (R) and resistive plus inductive (R-L) loads are simulated in this study. To demonstrate the effectiveness of the suggested converter, a laboratory prototype is constructed. In order to demonstrate the viability of the suggested arrangement, the experimental results for step variation in load demand and variation in modulation index under practical loading situations are obtained.

21 July 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
AAAhmed Amin
Ahmed Amin
MEMohamed Ebeed
Mohamed Ebeed
LNLoai Nasrat
Loai Nasrat
Mokhtar AlyMokhtar Aly
Mokhtar Aly
EAEmad M. Ahmed
Emad M. Ahmed
AHAmal M. Abd El Hamed
Amal M. Abd El Hamed
Nowadays, the trend of countries and their electrical sectors moves towards the inclusion of renewable distributed generators (RDGs) to diminish the use of the fossil fuel based DGs. The solar photovoltaic-based DG (PV-DG) is widely used as a clean and sustainable energy resource. Determining the best placements and ratings of the PV-DG is a significant task for the electrical systems to assess the PV-DG potentials. With the capability of the PV-DG inverters to inject the required reactive power in to the system during the night period or during cloudy weather adds the static compensation (STATCOM) functionality to the PV unit, which is being known as distributed static compensator (DSTATCOM). In the literature, there is a research gap relating the optimal allocation of the PV-DGs along with the seasonal variation of the solar irradiance. Therefore, the aim of this paper is to determine the optimal allocation and sizing of the PV-DGs along with the optimal injected reactive power by their inverters. An efficient optimization technique called Gorilla troop’s optimizer (GTO) is used to solve the optimal allocation problem of the PV-DGs with DSTATCOM functionality on a 94 bus distribution network. Three objective functions are used as a multi-objective function, including the total annual cost, the system voltage deviations, and the system stability. The simulation results show that integration of PV-DGs with the DSTATCOM functionality show the superiorities of reducing the total system cost and considerably enhancing system performance in voltages deviations and system stability compared to inclusion of the PV-DGs without the DSTATCOM functionality. The optimal integration of the PV-DGs with DSTATCOM functionality can reduce the total cost and the voltage deviations by 15.05% and 77.05%, respectively. While the total voltage stability is enhanced by 25.43% compared to the base case.

2 September 2024 in IEEE Access
Verified
Journal Article
Open access
TATayyab Ali
Tayyab Ali
MAMuhammad Asad
Muhammad Asad
Ezzeddine ToutiEzzeddine Touti
Ezzeddine Touti
BGBesma Bechir Graba
Besma Bechir Graba
MAMouloud Aoudia
Mouloud Aoudia
WNWaleed Nureldeen
Waleed Nureldeen
The increasing expansion of the industrial and domestic sectors, combined with the integration of renewable energy sources, has led to an overload of the existing interconnected power systems, which in turn has led to significant bottlenecks. This confluence of factors manifests itself in severe frequency, voltage and tie-line power issues, highlighting the urgent need for intelligent control mechanisms. Automatic voltage regulation (AVR) and load frequency control (LFC) are key components that ensure the supply of high-quality energy to consumers while maintaining the nominal frequency, voltage and power deviations in the grid. These measures are essential to ensure the stability and safety of the IPS under these challenging conditions. This research addresses the control strategies for a four-area sophisticated IPS. The complexity of the system, which includes five generation units in each area, including gas, thermal reheating, hydropower and two renewable energy sources (wind and photovoltaic), requires a careful study of the control methods. In particular, the inclusion of various non-linear factors, such as the governor dead band (GDB), generation rate constraint (GRC) and boiler dynamics (BD) in each of the four areas, increases the realism of the study. In this context, a recently introduced meta-heuristic algorithm, the One-to-One-based Optimizer (OOBO), was used to determine the optimal parameters of the proportional-integral-proportional-derivative (PI-PD) controller. The tuning process involves using the integral of time multiplied by the squared error value (ITSE) as the error criterion for evaluating the fitness function. In the study, the voltage, frequency and power performance of the OOBO PI-PD controller is evaluated and compared with alternative control methods, namely Proportional-Integral-Derivative (PID), Integral-Proportional (I-P) and Integral-Proportional-Derivative (I-PD) controllers, all of which are tuned with OOBO. Under the influence of a 5% load step load perturbation (SLP), comprehensive comparisons show the superior performance of the OOBO PI-PD controller, which shows better responses in all areas. Furthermore, the reliability and effectiveness of the OOBO PI-PD method are validated by a sensitivity analysis that considers simultaneous variations of the turbine time constant and speed control within a range of ±25%. The results highlight the robustness of the OOBO-PI-PD control strategy and demonstrate its ability to effectively stabilize variations in terminal voltage, load frequency and tie-line power with a significantly shorter settling time within the complicated dynamics of a four-area IPS with nonlinearities.

28 December 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
EAEmad M. Ahmed
Emad M. Ahmed
Mokhtar AlyMokhtar Aly
Mokhtar Aly
MMManar Mostafa
Manar Mostafa
Hegazy RezkHegazy Rezk
Hegazy Rezk
HAHammad Alnuman
Hammad Alnuman
WAWaleed Alhosaini
Waleed Alhosaini
Recently, there has been increasing concerns over bifacial PV (BPV) modules over the conventional monofacial PV (MPV) modules owing to their potential to add extra electrical energy from their rear-side irradiance. However, adding the rear-side irradiance to the front-side irradiance results in the increased nonlinearity of the BPV modules compared to MPV modules. Such nonlinearity makes the conventional methods unable to accurately extract the BPV module parameters. In this context, the precise determination of the BPV module parameters is a crucial issue for establishing energy yield estimations and for the proper planning of BPV installations as well. This paper proposes a new model for the BPV modules based on the MPV modeling, in which a new parameter is added to the MPV model to adjust the value of the model series resistance in order to provide a generic model for BPV modules in both monofacial and bifacial operating regions. Moreover, a new determination method for optimizing BPV model parameters using the recently developed enhanced version of the success-history-based adaptive differential evolution (SHADE) algorithm with linear population size reduction, known as the LSHADE method, is applied. The determination process of the model parameters is adapted using a two-stage optimization scheme to model the full operating range of BPV modules. The accuracy of the obtained parameters using the proposed model is compared with the conventional single-diode and double-diode models of the BPV. The obtained results using the proposed model of the BPV module show the performance superiority and accuracy of the LSHADE method over the existing methods in the literature. Furthermore, the LSHADE method provides the successful and accurate extraction of the global optimized parameters to model MPV and BPV modules. Therefore, the proposed method can provide an accurate model for the whole operating range of BPV that would be beneficial for further studies of their economic and technical feasibility for wide installation plans.

28 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
Ghulam AbbasGhulam Abbas
Ghulam Abbas
ABAqeel Ahmed Bhutto
Aqeel Ahmed Bhutto
TJTouqeer Jumani
Touqeer Jumani
Sohrab MirsaeidiSohrab Mirsaeidi
Sohrab Mirsaeidi
MTMohsin Ali Tunio
Mohsin Ali Tunio
AAAhmed Alshahir
Ahmed Alshahir
The increasing penetration of Distributed Generators (D.G.) into the existing power system has brought some real challenges regarding the transient response of electrical systems. The injection of D.G.s and abrupt load changes may cause massive power, current, and voltage overshoots/undershoots, which consequently affects the equilibrium of the existing power system and deteriorate the performance of the connected electrical appliances. A robust and intelligent control strategy is of utmost importance to cope with these issues and enhance the penetration level of D.G.s into the existing power system. This paper presents a Modified Particle Swarm Optimization (MPSO) algorithm-based intelligent controller for attaining a desired power-sharing ratio between the M.G. and the main grid with an optimal transient response in a grid-tied Microgrid (M.G.) system. The proposed MPSO algorithm includes an additional parameter named best neighbor particles (rbest) in the velocity updating equation to convey additional information to every individual particle about all its neighbor particles, consequently leading to the increased exploration capability of the algorithm. The MPSO algorithm optimizes P.I. parameters for transient and steady-state response improvement of the studied M.G. system. The main dynamic response evaluation parameters are the overshoot and settling time for active and reactive power during the D.G. connection and load change. Furthermore, the performance of the proposed controller is compared with the PI-PSO-based MG controller, which validates the effectiveness of the proposed M.G. control scheme in maintaining the required active and reactive power under different operating conditions with minimum possible overshoot and settling time.