The report of an IUPAC Task Group, formed in 2011 on “Intensities and line shapes in high-resolution spectra of water isotopologues from experiment and theory” (Project No. 2011-022-2-100), on line profiles of isolated high-resolution rotational-vibrational transitions perturbed by neutral gas-phase molecules is presented. The well-documented inadequacies of the Voigt profile (VP), used almost universally by databases and radiative-transfer codes, to represent pressure effects and Doppler broadening in isolated vibrational-rotational and pure rotational transitions of the water molecule have resulted in the development of a variety of alternative line-profile models. These models capture more of the physics of the influence of pressure on line shapes but, in general, at the price of greater complexity. The Task Group recommends that the partially Correlated quadratic-Speed-Dependent Hard-Collision profile (pCqSD-HCP) should be adopted as the appropriate model for high-resolution spectroscopy. For simplicity this should be called the Hartmann–Tran profile (HTP). The HTP is sophisticated enough to capture the various collisional contributions to the isolated line shape, can be computed in a straightforward and rapid manner, and reduces to simpler profiles, including the Voigt profile, under certain simplifying assumptions.
A comprehensive investigation of the frequency-noise spectral density of a free-running midinfrared quantum-cascade laser is presented for the first time. It provides direct evidence of the leveling of this noise down to a white-noise plateau, corresponding to an intrinsic linewidth of a few hundred hertz. The experiment is in agreement with the most recent theory on the fundamental mechanism of line broadening in quantum-cascade lasers, which provides a new insight into the Schawlow-Townes formula and predicts a narrowing beyond the limit set by the radiative lifetime of the upper level.
Small molecules exhibit characteristic ro-vibrational transitions in the near- and mid-infrared spectral regions, which are strongly influenced by isotopic substitution. This gift of nature has made it possible to use laser spectroscopy for the accurate analysis of the isotopic composition of gaseous samples. Nowadays, laser spectroscopy is clearly recognized as a valid alternative to isotope ratio mass spectrometry. Laser-based instruments are leaving the research laboratory stage and are being used by a growing number of isotope researchers for significant advances in their own field of research. In this review article, we discuss the current status and new frontiers of research on high-sensitivity and high-precision laser spectroscopy for isotope ratio analyses. Although many of our comments will be generally applicable to laser isotope ratio analyses in molecules of environmental importance, this paper concerns itself primarily with water and carbon dioxide, two molecules that were studied extensively in our respective laboratories. A complete coverage of the field is practically not feasible in the space constraints of this issue, and in any case doomed to fail, considering the large body of work that has appeared ever since the review by Kerstel in 2004 (Handbook of Stable Isotope Analytical Techniques, Chapt. 34, pp. 759–787).
1 December 1999 in Journal of the Optical Society of America B
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
We report on a new optical implementation of primary gas thermometry based on laser-absorption spectrometry in the near infrared. The method consists in retrieving the Doppler broadening from highly accurate observations of the line shape of the R(12) nu1+2nu2(0)+nu3 transition in CO2 gas at thermodynamic equilibrium. Doppler width measurements as a function of gas temperature, ranging between the triple point of water and the gallium melting point, allowed for a spectroscopic determination of the Boltzmann constant with a relative accuracy of approximately 1.6 x 10(-4).
We report on a new implementation of Doppler broadening thermometry based on precision absorption spectroscopy by means of a pair of offset-frequency locked extended-cavity diode lasers at $1.39\text{ }\text{ }$\mu${}\mathrm{m}$. The method consists in the highly accurate observation of the shape of the ${4}_{4,1}$\rightarrow${}{4}_{4,0}$ line of the ${\mathrm{H}}_{2}^{18}\mathrm{O}$ ${$\nu${}}_{1}+{$\nu${}}_{3}$ band, in a water vapor sample at thermodynamic equilibrium. A sophisticated and extremely refined spectral analysis procedure is adopted for the retrieval of the Doppler width as a function of the gas pressure, taking into account the Dicke narrowing effect, the speed dependence of relaxation rates, and the physical correlation between velocity-changing and dephasing collisions. A spectroscopic determination of the Boltzmann constant with a combined (type $A$ and type $B$) uncertainty of 24 parts over ${10}^{6}$ is reported. This is the best result obtained so far by means of an optical method. Our determination is in agreement with the recommended CODATA value.