A case of underground long-term hot water storage is investigated numerically. The study is based on the unsteady two-dimensional Navier-Stokes equations in Boussinesq approximation applied to a closed cavern with time-dependent temperature boundary conditions on the walls. The problem formulated in a vorticity-stream function statement is solved by finite difference method (FDM) for high values of the Rayleigh number and for the Prandtl number of water. Streamlines, velocity and temperature fields are presented graphically for given moments of time. The evolution of the thermocline thickness in the mid-section of the cavern is slow and illustrates that the hot water zone occupies more than the half of the cavern even after 6 months period. The Nusselt number on the walls shows that the convective thermal losses are small and after certain period of time tend to decrease due to the diminished temperature difference at the walls. The influence of the fluid convection on the thermal losses is evaluated quantitatively, showing high seasonal thermal efficiency of the insulated hot water storage.
The present paper is motivated by challenges in the design of the surface insulation in borehole thermal energy storage (BTES). A case study of a BTES with nine borehole heat exchangers (BHEs) in a cold climate is considered. Transient numerical modeling of the storage charging phase is performed by solving the three-dimensional heat equation using the finite difference method. Heat conduction through the insulation cover is simulated in accordance with Fourier’s law. A parametric study is conducted with respect to the prescribed heating setpoint temperatures in the BHEs and to the geometry of the insulation cover. The thermal analysis shows that the efficiency of the storage volume is strongly dependent on the heat transfer through the upper boundary. The insulation layer affects the minimum temperature reached within the BTES, with the influence of insulation thickness being most pronounced at thicknesses up to 10 cm. Furthermore, it is demonstrated that the lateral extension of the insulation cover has a greater impact on storage capacity gains than increasing its thickness, and that these energy gains expand progressively over time. Under cold ambient conditions, effective seasonal storage requires managing sharp ambient thermal gradients via a wider peripheral coverage of the insulation layer to offset vertical conductive losses.
20 January 2025 in Facta Universitatis, Series: Working and Living Environmental Protection
Impedance tubes are used to characterize porous acoustic materials. The report proposes a suitable model for numerical simulations of the test of materials in an impedance tube. Numerical simulations make it possible to generate synthetic data on the acoustic characteristics of the material when varying the parameters in the material model. These data are suitable for using machine learning algorithms as well as for solving inverse problems for identifying the material parameters in the mathematical model. The Johnson-Champoux-Allard model is used in the work, which is suitable for a wide class of porous acoustic materials.
A case of underground long-term hot water storage is investigated numerically. The study is based on the unsteady two-dimensional Navier-Stokes equations in Boussinesq approximation applied to a closed cavern with time-dependent temperature boundary conditions on the walls. The problem formulated in a vorticity-stream function statement is solved by finite difference method (FDM) for high values of the Rayleigh number and for the Prandtl number of water. Streamlines, velocity and temperature fields are presented graphically for given moments of time. The evolution of the thermocline thickness in the mid-section of the cavern is slow and illustrates that the hot water zone occupies more than the half of the cavern even after 6 months period. The Nusselt number on the walls shows that the convective thermal losses are small and after certain period of time tend to decrease due to the diminished temperature difference at the walls. The influence of the fluid convection on the thermal losses is evaluated quantitatively, showing high seasonal thermal efficiency of the insulated hot water storage.