A horizontal ferrofluid layer is submitted to a lateral heating and to a strong oblique magnetic field. The problem, combining the momentum and heat balance equations with the Maxwell equations, introduces two Rayleigh numbers, Ra the gravitational one and Ram the magnetic one, to represent the buoyancy and the Kelvin forces, which induce motion, versus the momentum viscous diffusion and heat diffusion. Whatever the inclination of the magnetic field, the steady solution of the problem is presented as a power series of a small parameter ϵH measuring the ratio of variation of the magnetization across the layer divided by the magnitude of the external imposed field. For cases of physical relevance, comparisons between analytical and numerical studies have lead to a major statement: in the strong field region (ϵH≪1) the zero order solution is the product of the Birikh solution that corresponds to the usual Newtonian fluid submitted to a lateral gradient, multiplied by a modulating factor accounting for inclination and both Rayleigh numbers. Physically, this simplified solution is valid for microgravity conditions where the magnetic field competes enough with microgravity effects to invert the laminar flow and thus suppress the motion for two specific values of the inclination angle.
A case of underground long-term hot water storage is investigated numerically. The study is based on the unsteady two-dimensional Navier-Stokes equations in Boussinesq approximation applied to a closed cavern with time-dependent temperature boundary conditions on the walls. The problem formulated in a vorticity-stream function statement is solved by finite difference method (FDM) for high values of the Rayleigh number and for the Prandtl number of water. Streamlines, velocity and temperature fields are presented graphically for given moments of time. The evolution of the thermocline thickness in the mid-section of the cavern is slow and illustrates that the hot water zone occupies more than the half of the cavern even after 6 months period. The Nusselt number on the walls shows that the convective thermal losses are small and after certain period of time tend to decrease due to the diminished temperature difference at the walls. The influence of the fluid convection on the thermal losses is evaluated quantitatively, showing high seasonal thermal efficiency of the insulated hot water storage.