19 May 2016 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
KPKonstantinos Papadimitriou
Konstantinos Papadimitriou
CWChu Wang
Chu Wang
MRMichelle L. Rogers
Michelle L. Rogers
SGSally A. N. Gowers
Sally A. N. Gowers
CLChi L. Leong
Chi L. Leong
EDEmm. Mic. Drakakis
Emm. Mic. Drakakis
Traumatic brain injury (TBI) has been identified as an important cause of death and severe disability in all age groups and particularly in children and young adults. Central to TBI’s devastation is a delayed secondary injury that occurs in 30-40% of TBI patients each year, while they are in the hospital Intensive Care Unit (ICU). Secondary injuries reduce survival rate after TBI and usually occur within 7 days post-injury. State-of-art monitoring of secondary brain injuries benefits from the acquisition of high-quality and time-aligned electrical data i.e. ElectroCorticoGraphy (ECoG) recorded by means of strip electrodes placed on the brain’s surface, and neurochemical data obtained via rapid sampling microdialysis and microfluidics-based biosensors measuring brain tissue levels of glucose, lactate and potassium. This article progresses the field of multi-modal monitoring of the injured human brain by presenting the design and realisation of a new, compact, medical-grade amperometry, potentiometry and ECoG recording bioinstrumentation. Our combined TBI instrument enables the high-precision, real-time neuroelectrochemical monitoring of TBI patients, who have undergone craniotomy neurosurgery and are treated sedated in the ICU. Electrical and neurochemical test measurements are presented, confirming the high-performance of the reported TBI bioinstrumentation.

12 June 2021 in Advanced Functional Materials
Verified
Journal Article
Open access
PDF file
JTJames E. Tyrrell
James E. Tyrrell
KPKonstantinos Petkos
Konstantinos Petkos
EDEmm. Mic. Drakakis
Emm. Mic. Drakakis
MBMartyn G. Boutelle
Martyn G. Boutelle
ACAlasdair J. Campbell
Alasdair J. Campbell
The portability of physiological monitoring has necessitated the biocompatibility of components used in circuitry local to biological environments. A key component in processing circuitry is the linear amplifier. Amplifier circuit topologies utilize transistors, and recent advances in bioelectronics have focused on organic electrochemical transistors (OECTs). OECTs have shown the capability to transduce physiological signals at high signal‐to‐noise ratios. In this study high‐performance interdigitated electrode OECTs are implemented in a common source linear amplifier topology. Under the constraints of OECT operation, stable circuit component parameters are found, and OECT geometries are varied to determine the best amplifier performance. An equation is formulated which approximates transistor behavior in the linear, nonlinear, and saturation regimes. This equation is used to simulate the amplifier response of the circuits with the best performing OECT geometries. The amplifier figures of merit, including distortion characterizations, are then calculated using physical and simulation measurements. Based on the figures of merit, prerecorded electrophysiological signals from spreading depolarizations, electrocorticography, and electromyography fasciculations are inputted into an OECT linear amplifier. Using frequency filtering, the primary features of events in the bioelectric signals are resolved and amplified, demonstrating the capability of OECT amplifiers in bioelectronics.

19 January 2013 in Journal of Signal Processing Systems
Verified
Journal Article
Closed access
PDF file
AEAmir Eftekhar
Amir Eftekhar
CTChristofer Toumazou
Christofer Toumazou
EDEmm. Mic. Drakakis
Emm. Mic. Drakakis

10 December 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
KPKonstantinos Petkos
Konstantinos Petkos
SKSimos Koutsoftidis
Simos Koutsoftidis
TGThomas Guiho
Thomas Guiho
PDPatrick Degenaar
Patrick Degenaar
AJAndrew Jackson
Andrew Jackson
EDEmm. Mic. Drakakis
Emm. Mic. Drakakis
Background: It is widely accepted by the scientific community that bioelectrical signals, which can be used for the identification of neurophysiological biomarkers indicative of a diseased or pathological state, could direct patient treatment towards more effective therapeutic strategies. However, the design and realisation of an instrument that can precisely record weak bioelectrical signals in the presence of strong interference stemming from a noisy clinical environment is one of the most difficult challenges associated with the strategy of monitoring bioelectrical signals for diagnostic purposes. Moreover, since patients often have to cope with the problem of limited mobility being connected to bulky and mains-powered instruments, there is a growing demand for small-sized, high-performance and ambulatory biopotential acquisition systems in the Intensive Care Unit (ICU) and in High-dependency wards. Finally, to the best of our knowledge, there are no commercial, small, battery-powered, wearable and wireless recording-only instruments that claim the capability of recording electrocorticographic (ECoG) signals. Methods: To address this problem, we designed and developed a low-noise (8 nV/√Hz), eight-channel, battery-powered, wearable and wireless instrument (55 × 80 mm2). The performance of the realised instrument was assessed by conducting both ex vivo and in vivo experiments. Results: To provide ex vivo proof-of-function, a wide variety of high-quality bioelectrical signal recordings are reported, including electroencephalographic (EEG), electromyographic (EMG), electrocardiographic (ECG), acceleration signals, and muscle fasciculations. Low-noise in vivo recordings of weak local field potentials (LFPs), which were wirelessly acquired in real time using segmented deep brain stimulation (DBS) electrodes implanted in the thalamus of a non-human primate, are also presented. Conclusions: The combination of desirable features and capabilities of this instrument, namely its small size (~one business card), its enhanced recording capabilities, its increased processing capabilities, its manufacturability (since it was designed using discrete off-the-shelf components), the wide bandwidth it offers (0.5–500 Hz) and the plurality of bioelectrical signals it can precisely record, render it a versatile and reliable tool to be utilized in a wide range of applications and environments.

27 August 2004 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
DHD. Hatzidimitriou
D. Hatzidimitriou
IVI. Vardavas
I. Vardavas
KPK. G. Pavlakis
K. G. Pavlakis
Nikolaos HatzianastassiouNikolaos Hatzianastassiou
Nikolaos Hatzianastassiou
Christos MatsoukasChristos Matsoukas
Christos Matsoukas
EDEmm. Mic. Drakakis
Emm. Mic. Drakakis
In the present paper, we have calculated the outgoing longwave radiation at the top of the atmosphere (OLR at TOA) using a deterministic radiation transfer model, cloud data from ISCCP-D, and atmospheric temperature and humidity data from NCEP/NCAR reanalysis, for the seventeen-year period 1984-2000. We constructed anomaly time-series of the OLR at TOA, as well as of all of the key input climatological data, averaged in the tropical region between 20°N and 20°S. We compared the anomaly time-series of the model calculated OLR at TOA with that obtained from the ERBE S-10N (WFOV NF edition 2) non-scanner measurements. The model results display very similar seasonal and inter-annual variability as the ERBS data, and indicate a decadal increase of OLR at TOA of 1.9±0.2Wm-2/decade, which is lower than that displayed by the ERBS time-series (3.5±0.3Wm-2). Analysis of the inter-annual and long-term variability of the various parameters determining the OLR at TOA, showed that the most important contribution to the observed trend comes from a decrease in high-level cloud cover over the period 1984-2000, followed by an apparent drying of the upper troposphere and a decrease in low-level cloudiness. Opposite but small trends are introduced by a decrease in low-level cloud top pressure, an apparent cooling of the lower stratosphere (at the 50mbar level) and a small decadal increase in mid-level cloud cover.

25 April 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
SKSimos Koutsoftidis
Simos Koutsoftidis
DBDeren Y. Barsakcioglu
Deren Y. Barsakcioglu
KPKonstantinos Petkos
Konstantinos Petkos
DFDario Farina
Dario Farina
EDEmm. Mic. Drakakis
Emm. Mic. Drakakis
Objective: We present Myolink, a portable, modular, low-noise electrophysiology amplifier optimized for high-density surface electromyogram (HD sEMG) acquisition. Methods: Myolink consists of 4 modules. Each 10 × 8 cm module can concurrently acquire 32 unipolar electrode potentials at sampling rates of up to 8 kHz with 24-bit resolution. Modules may be stacked and operated synchronously, supporting the concurrent acquisition of up to 128 channels. A custom high-performance analog front-end provides an input-referred-noise $\mathbf {< 0.4}$ $\mu \mathbf {V}_{\mathbf {RMS}}$ for a bandwidth of 23–524 Hz (tuneable by design choices), which is lower than current commercial systems. Digitized signals are processed by a custom on-board FPGA-based controller and subsequently transmitted to a PC via a medical-grade isolated USB 2.0 interface. Results: The system has been tested by recording experimental HD sEMG signals, which have been subsequently decomposed into motor unit action potentials. Compared to commercially available systems, the proposed recording system led to higher-quality surface EMG acquisition, as well as higher decomposition accuracy across a wide range of forces, with the greater gain for forces $\leq$ 20% of the maximum voluntary contraction. Significance: A portable, ultra-low-noise, HD sEMG amplifier design has been implemented and characterized. The system provides IRN performance beyond the capabilities of current state-of-the-art instrumentation and this improvement has a significant effect on HD sEMG decomposition.