dragan mlakić

Dr. dragan mlakić

Artificial Intelligence
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
HBHamid Reza Baghaee
Hamid Reza Baghaee
DMdragan mlakić
dragan mlakić
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
TDTomislav Dragicevic
Tomislav Dragicevic
Many techniques used and still in usage for solving the problem of islanding detection are intrinsically passive, active, or hybrid of both. Each one of them has its own benefits and drawbacks. In this paper, we propose a method which takes the advantage of a ML-based algorithm, namely SVM, in order to produce the results more efficiently. The results of the simulations based on the model and experimentally-measured parameters of a real-life practical PV plant, gives much better output than the traditional reported methods. During the tests and simulations, an additional problem, namely grid fault emerged, posing new challenges for the proposed method. Occurrences of islanding and grid fault are grouped together with same kernel dimension and no custom hyper plane bordering. Discrimination between islanding and grid fault events is an essential dilemma which is handled by the proposed SVM-based algorithm to achieve more precision in islanding detection and simultaneously, detect the grid faults authentically. NDZs and DT are tested using two dimensions, namely the generated active energy from PV plant (0-110% of Pn), and distribution network voltage levels (± 10% of Un). Simulations based on the model and parameters of a real-life practical PV power plant are performed in MATLAB/Simulink environment and several tests are executed for several scenarios, Finally, comparisons with previously-reported techniques prove the effectiveness, authenticity, selectivity, accuracy and precision of the proposed islanding and grid fault detection strategy with allowable impact on power quality according to UL1741 and its superiority over other methods.

24 July 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
DMdragan mlakić
dragan mlakić
HBHamid Reza Baghaee
Hamid Reza Baghaee
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
This paper presents a new islanding detection strategy for low-voltage (LV) inverter-interfaced microgrids based on adaptive neuro-fuzzy inference system (ANFIS). The proposed islanding detection method exploits the pattern recognition capability of ANFIS and its nonlinear mapping of relation between inputs. The ANFIS monitors seven inputs measured at point of common coupling (PCC), namely root-mean square (RMS) of voltage and current (RMSU and RMSI), total harmonic distortion (THD) of voltage and current (THDU and THDI), frequency (f), and also active and reactive powers (P, Q) that are experimentally obtained based on practical measurement in a real-life microgrid. The proposed method is composed of passive monitoring of the mentioned inputs and therefore, does not influence power quality (PQ); but considerably decreases non detection zones (NDZs). In order to cover as much situations as possible, minimizing false tripping and still remaining selective, type and number of samples are introduced. Here, one of the main goals is reducing NDZ by still keeping PQ in order. Based on the sampled frequency and number of samples, we find that the proposed method has less detection time and better accuracy, compared to the reported methods. Simulations performed in MATLAB/Simulink software environment and several tests performed based on different active load conditions and multiple distributed generation (DG)s, prove the effectiveness, authenticity, selectivity, accuracy and precision of the proposed method with allowable impact on PQ according to UL1741 standard.

21 June 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
HBHamid Reza Baghaee
Hamid Reza Baghaee
DMdragan mlakić
dragan mlakić
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
TDTomislav Dragicevic
Tomislav Dragicevic
The cheap and reliable primal energy source for BESS refueling necessitates a special attention for combining RERs with PHEV charging stations in microgrids. Rapid charging is an operation mode of PHEV for drivers which demands fast recharging of BESSs of the electric cars. This charging mode manifests as low impedance short circuit at DC side, making power transient on power grid side. This paper presents a new anti-islanding protection scheme for LV VSC-based microgrids by exploiting SVMs. The proposed anti-islanding protection method exploits powerful classification capability of SVMs. The sensor monitors seven inputs measured at the PCC, namely RMS value of voltage and current (RMSV, RMSI), THD of voltage and current (THDV, THDI), frequency (f), and also active and reactive powers (P, Q). This approach is based on passive monitoring and therefore, it does not affect the PQ. In order to cover as many situations as possible, minimize false tripping and remain selective, training and detection procedures are simply introduced. Based on the presented sampling method and input model, the proposed method is tested under different conditions such as PHEV rapid charging, additional load change and multiple DGs at the same PCC. Simulations based on the model and parameters of a real-life practical PV power plant are performed in MATLAB/Simulink environment, and several tests are executed based on different scenarios and compared with previously-reported techniques, this analysis proved the effectiveness, authenticity, selectivity, accuracy and precision of the proposed method with allowable impact on PQ according to UL1741 standard, and its superiority over other methods.

27 November 2018 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
DMdragan mlakić
dragan mlakić
HBHamid Reza Baghaee
Hamid Reza Baghaee
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
One of the most crucial problems in distribution networks (DNs) is islanding detection. This paper presents a new Gibbs phenomenon-based hybrid method for islanding detection in low voltage (LV) DNs, which is essentially based on a combination of active and passive methods of frequency rate of change at a given moment and measurement of constant total harmonic distortion (THD). The proposed method exploits Gibbs phenomenon occurring at the interpolation of sinusoidal functions. Beside identification of Gibbs phenomenon, root mean square (RMS) of the voltage is tracked in parallel with THDU for firm islanding detection. Finally, to prove the effectiveness of the proposed islanding detection strategy, offline digital time-domain simulation studies have been performed on a test microgrid including voltage-sourced converter (VSC)-based renewable/ distributed energy resources (RERs/DERs) in MATLAB/Simulink environment for different configurations and load conditions and the results have been verified by comparing with previously-reported methods. The results indicate that the proposed method performs fast and precise islanding detection in both low-power and high-power LV microgrids with reasonable impact on power quality (PQ) according to EN 50160 standard. By combining these fields as active and passive techniques, the proposed hybrid method gives non detection zones (NDZs) and detection time (DT) much smaller compared with frequency-and harmonic-based individual islanding detection methods.

29 October 2018 in Energies
Verified
Journal Article
Open access
PDF file
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
HBHamid Reza Baghaee
Hamid Reza Baghaee
DMdragan mlakić
dragan mlakić
One of the most crucial and economically-beneficial tasks for energy customers is peak load curtailment. On account of the fast response of renewable energy resources (RERs) such as photovoltaic (PV) units and battery energy storage system (BESS), this task is closer to be efficiently implemented. Depends on the customer peak load demand and energy characteristics, the feasibility of this strategy may vary. When adaptive neuro-fuzzy inference system (ANFIS) is exploited for forecasting, it can provide many benefits to address the above-mentioned issues and facilitate its easy implementation, with short calculating time and re-trainability. This paper introduces a data-driven forecasting method based on fuzzy logic (FL) for optimized peak load reduction. First, the amount of energy generated by PV is forecasted using ANFIS which conducts output trend, and then, the BESS capacity is calculated according to the forecasted results. The trend of the load power is then decomposed in Cartesian plane into two parts, namely left and right from load peak, for the sake of searching for equal BESS capacity. Network switching sequence over consumption is provided by a fuzzy logic controller (FLC) considering BESS capacity and PV energy output. Finally, to prove the effectiveness of the proposed ANFIS-based peak power shaving/curtailment method, offline digital time-domain simulations have been performed on a test microgrid system using the data gathered from a real-life practical test microgrid system in the MATLAB/Simulink environment and the results have been experimentally verified by testing on a practical microgrid system with real-life data obtained from smart meters and also, compared with several previously-reported methods.

1 May 2016
Verified
Conference Paper
Closed access
DMdragan mlakić
dragan mlakić
Srete NikolovskiSrete Nikolovski
Srete Nikolovski
Photovoltaic systems as part of larger distribution systems for the production of electricity have non-linear current-voltage characteristics. These characteristics depend on the temperature of the solar cells and insolation of panels. The method for the search of the maximum power or MPPT is widely known, and there are many offered algorithm solutions. The aim of this paper is to present ANFIS (Adaptive Neural Fuzzy System Inference) as a method of computer intelligence in the search function of maximum power or maximum utilization of the PV system, without prior knowledge of the system. MPPT ANFIS will be located between the PV panels and devices for voltage regulation. Inputs used to go inside the fuzzy regulators and outputs of the fuzzy regulators are going into power changing device. The advantage of this method is the low cost of implementation because it uses embedded computer systems and does not require additional sensors for measuring temperature and insolation. It is very easy to upgrade in the case of increasing the knowledge base used in FIS membership function. Everything is simulated by MATLAB/Simulink software on the one-phase IBC system.