Tomasz Pander

Dr. Tomasz Pander

Silesian University of Technology, Gliwice, Śląskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
JWJanusz Wróbel
Janusz Wróbel
KHKrzysztof Horoba
Krzysztof Horoba
TPTomasz Pander
Tomasz Pander
JJJanusz Jezewski
Janusz Jezewski
RCRobert Czabanski
Robert Czabanski

8 March 2022 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
TPTomasz Pander
Tomasz Pander

1 June 2010 in Signal Processing
Verified
Journal Article
Closed access
TPTomasz Pander
Tomasz Pander

21 March 2019 in Signal, Image and Video Processing
Verified
Journal Article
Open access
PDF file
TPTomasz Pander
Tomasz Pander
Noise reduction methods have a great impact on the performance of all EEG signal processing systems. The work involves the reduction in impulsive interferences. It is impossible to suppress effectively such a noise using linear filtering approach. The work presents the properties of a cascaded filter based on the ordered weighted aggregation (OWA) operator and its application to improve the electroencephalogram (EEG) signal. The OWA operator is a class of mean-like aggregation operators. By introducing a nonlinear sorting process and by assigning appropriate values of weights to the sorted samples, the improvement in filtering in the impulsive environment is achieved. The structure of the proposed cascade consists of two layers. The first layer contains two OWA filters that share a certain number of signal samples. The second layer averages the outputs of the first layer. The algorithm for the rise of filtering efficiency has been introduced. The performance of the new method has been experimentally compared with the traditional methods of impulsive noise reduction, using synthetic as well as real signals from the CHB-MIT database. The obtained results demonstrate that in the field of impulsive noise suppression and preprocessing, the proposed cascaded OWA filter brings about a significant improvement in the signal-to-noise ratio.

1 August 2015 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
MKMarian Kotas
Marian Kotas
TPTomasz Pander
Tomasz Pander
JLJacek M. Leski
Jacek M. Leski

1 May 2008
Verified
Conference Paper
Closed access
TPTomasz Pander
Tomasz Pander
TPTomasz Przybyla
Tomasz Przybyla
RCRobert Czabanski
Robert Czabanski
The electrooculogram represents the electrical activity of muscles which steering of movements of an eye. The eye blinking is a natural protection system which defends the eye from environmental exposure. The spontaneous eye blink is considered to be a suitable indicator for fatigue diagnostics during many, different tasks of human being activity. The detection function is used to detect the spontaneous eye blink action. On this base the position of an eye blink is estimated. The results demonstrate that the measurement of an eye blink parameter provides reliable information for eye-controlled systems from human-machine interface.