Jia Huang

Dr. Jia Huang


Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2025 in BMC Pregnancy and Childbirth
Verified
Journal Article
Open access
PDF file
QZQinghong Zhao
Qinghong Zhao
WQWenqiong Qin
Wenqiong Qin
HPHuijiao Pan
Huijiao Pan
WDWen Ding
Wen Ding
YWYandan Wang
Yandan Wang
QZQing Zhou
Qing Zhou
Intramural pregnancy, a rare ectopic pregnancy with the gestational sac implanted within the myometrium, poses significant diagnostic and therapeutic chall

15 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
JHJia Huang
Jia Huang
YZYao Zhang
Yao Zhang
HPHuan Pu
Huan Pu
BSBin Sun
Bin Sun
XHXingyue Huang
Xingyue Huang
QZQing Zhou
Qing Zhou
Background/Objectives: Rectovaginal fistula (RVF) is a challenging condition that can substantially impair quality of life and often requires individualized surgical management. Accurate preoperative imaging is essential for identifying fistulous tracts, assessing pelvic floor involvement, and guiding surgical planning. However, conventional imaging modalities, including magnetic resonance imaging (MRI), may still have limitations in detecting small, occult, intermittently patent, or anatomically complex fistulas, particularly under static imaging conditions. This study aimed to evaluate the diagnostic performance of transperineal pelvic floor ultrasound (TPUS) combined with ultrasound contrast agent enema (UCAE) and its potential value in preoperative assessment of RVF. Methods: In this prospective single-center study, 62 women with surgically confirmed RVF were enrolled between January 2022 and April 2025. All patients underwent TPUS combined with UCAE before surgery, while subsets also underwent contrast-enhanced CT, contrast-enhanced MRI, or barium enema according to clinical indications. Imaging findings were compared with intraoperative findings as the reference standard. Fistula detection, morphological classification, size, anatomical location, pelvic floor injury assessment, and concordance between ultrasound-based surgical proposals and actual surgical procedures were systematically analyzed. Comparative analyses with conventional imaging modalities were performed based on available non-paired subgroups. Results: UCAE detected RVF in 60 of 62 patients, yielding a detection rate of 96.8%. In the available comparative cohort, UCAE demonstrated higher detection rates than conventional imaging modalities, particularly in small and complex fistulas. UCAE showed high agreement with intraoperative findings in terms of fistula morphology, size, and anatomical location. TPUS provided additional and complementary information regarding levator ani and anal sphincter injuries and yielded higher sensitivity and accuracy in pelvic floor injury assessment within the studied cohort. Ultrasound-based surgical proposals showed directional concordance with final intraoperative decisions in 88.7% of cases. No adverse events were observed during UCAE. Conclusions: TPUS combined with UCAE appears to be a safe and feasible preoperative imaging approach for RVF. By integrating fistula detection, anatomical classification, pelvic floor assessment, and surgical planning, this combined ultrasound approach may serve as a complementary imaging strategy to conventional imaging modalities, particularly for small or intermittently patent fistulas. Further multicenter studies and standardized imaging protocols are warranted to validate its clinical utility and generalizability.

1 June 2026 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
JHJuan He
Juan He
ZDZhimin Deng
Zhimin Deng
QCQian Chen
Qian Chen
SXShu Xian
Shu Xian
TYTai-lang Yin
Tai-lang Yin
JHJia Huang
Jia Huang
Background: Rats are commonly used model animals in reproductive system and embryonic development research, and accurate pregnancy staging and gestational age (GA) assessment are crucial for experimental studies. Traditional methods (such as vaginal plug examination and abdominal palpation) have limitations and cannot precisely determine the time of fertilization or assess embryonic developmental features. As a noninvasive and convenient real-time imaging technique, ultrasonography has been widely used in human fetal assessment but has been less intensively applied in rat pregnancy research. This study aimed to use commercial high-frequency two-dimensional (2D) and three-dimensional (3D) ultrasonography to establish and validate quantitative GA estimation formulae for rats, display the 3D structure of the gestational sac (GS) and fetal rat, and preliminarily examine the blood flow Doppler changes in pregnant rats and fetal rats. Methods: A total of 23 pregnant Wistar rats were included in the study and divided into an observation group (12 rats with detected vaginal plugs) and a validation group (11 rats without detected plugs but with ultrasonography-confirmed pregnancy). A Voluson E10 ultrasound diagnostic instrument (GE HealthCare), equipped with a 2D linear array probe (4–10 MHz) and a 3D volumetric probe (6–18 MHz), was used to examine the pregnant rats. Parameters such as the maximum diameter of the GS, crown-rump length (CRL), biparietal diameter (BPD), and abdominal circumference (AC) were measured, and linear and multiple regression models were constructed with GA serving as the dependent variable. The normality of data was verified via the Shapiro-Wilk test, and intraobserver reproducibility was assessed via intraclass correlation coefficients (ICCs). Doppler flow spectra of the maternal uterine artery (UtA) and fetal ductus venosus and umbilical artery were also analyzed. Results: The GS was first visualized on embryonic day 7 (E7). CRL demonstrated a strong linear correlation with GA from E9 to E15 (R2=0.95; P<0.001), while the combination of BPD and AC provided a more reliable estimation from E16 onward (R2=0.90; P<0.001). With higher GA, peak systolic velocity and end-diastolic velocity of the maternal UtA and fetal ductus venosus gradually increased, whereas the systolic:diastolic ratio and resistance index progressively decreased. All Doppler parameters showed excellent intraobserver reproducibility (ICC ≥0.85). In the prospective validation cohort (n=11), the GA prediction model achieved an overall accuracy of 81.82% within 1 day and 100% within 2 days. 3D ultrasonography clearly depicted the beaded distribution of GS and the spatial structure of fetal rats. Conclusions: Commercial high-frequency ultrasound facilitates the reliable and quantitative assessment of rat pregnancy and GA with good reproducibility. Serial Doppler imaging can reveal characteristic maternal-fetal hemodynamic changes throughout gestation. 3D ultrasonography allows for the noninvasive visualization of the spatial arrangement of GS and fetal morphology. These findings provide a standardized imaging protocol for future studies in rat reproductive toxicology, pharmacology, and pregnancy-related disease models.