Xingyue Huang

Xingyue Huang

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2014 in Inflammation
Verified
Journal Article
Closed access
PDF file
GHGangying Hu
Gangying Hu
XHXingyue Huang
Xingyue Huang
KZKai Zhang
Kai Zhang
HJHong Jiang
Hong Jiang
XHXiaorong Hu
Xiaorong Hu

1 October 2019 in Biomedicine & Pharmacotherapy
Verified
Journal Article
Open access
WHWei Hu
Wei Hu
XHXin Huang
Xin Huang
XHXingyue Huang
Xingyue Huang
WCWenwei Chen
Wenwei Chen
LHLidan Hao
Lidan Hao
ZCZubing Chen
Zubing Chen
T cells edited by chimeric antigen receptors (CAR) have shown great potential in the treatment of tumors, especially malignant blood tumors. However, there remain many obstacles in the CAR-T therapy against solid tumors, such as the expansion of CAR-T cells ex vivo and the exhaustion of CAR-T cells in vivo. In order to solve these problems, we described a novel CAR which is targeting GPC3 by expressing CD28 co-stimulation domain and CD3z ITAM (G328z), meanwhile co-expressing ICOSL extracellular and transmembrane region fused with 41BB cytoplasmic domain (G328z-ICOSL-41BB). Compared with G328z, G328z-ICOSL-41BB fusion protein significantly reinforced the expansion ability of CAR-T cells ex vivo, and prolonged the survival time of mice with hepatocellular carcinoma. We now demonstrate that the enhancement of CAR-T cell activity is dependent on the enhanced PI3K signaling pathway and up-regulated expression of Bcl2 to inhibit apoptosis and promote proliferation of CAR-T cells. Besides, the CAR with ICOSL-41BB fusion protein have been strengthened significantly in comparison with fusing ICOSL protein only, which might be caused by the fact that ICOSL-41BB not only supplies ICOS signal for other cells, but also provides 41BB signal for itself. Consequently, CARs with ICOSL-41BB fusion protein could increase the therapeutic efficacy against solid tumors in vivo compared with the G328z CAR, which might further assist the development of potent and durable T cell therapeutics.

1 June 2025 in International Journal of Nephrology and Renovascular Disease
Verified
Journal Article
Open access
PDF file
XHXingyue Huang
Xingyue Huang
YZYao Zhang
Yao Zhang
YHYugang Hu
Yugang Hu
JPJuhong Pan
Juhong Pan
XHXin Huang
Xin Huang
QZQing Zhou
Qing Zhou
Objective: This study aims to evaluate the diagnostic efficacy of shear wave elastography (SWE) and super-resolution imaging (SRI) in detecting moderate-to-severe renal fibrosis (MSRF) among patients with chronic kidney disease (CKD). Methods: In this prospective study, 202 CKD patients who underwent SWE and SRI prior to renal biopsy were enrolled. Based on pathological findings, patients were categorized into a mild renal fibrosis group (n=107) and an MSRF group (n=95). LASSO logistic regression was employed to identify independent risk factors for MSRF. Four diagnostic models—isolated, series, parallel, and integrated—were developed by combining elasticity values from SWE and vascular density values from SRI. Additionally, a nomogram incorporating clinical parameters and ultrasound composite parameters was constructed to assess MSRF in CKD patients. Results: LASSO and subsequent logistic regression analysis revealed that age, diabetes history, estimated glomerular filtration rate (eGFR), elasticity, and vascular density were independently associated with MSRF. The integrated model, utilizing a logistic algorithm, demonstrated superior diagnostic performance with an area under the curve (AUC) of 0.83 (P < 0.001), sensitivity of 80.4%, and specificity of 75.8%, outperforming all other models. Furthermore, the nomogram, which integrated clinical factors and ultrasound composite parameters, exhibited excellent predictive performance (AUC = 0.878, 95% CI 0.782– 0.974). Calibration and decision curve analyses confirmed the model’s robust calibration and clinical utility. Conclusion: The integration of SWE-derived elasticity and SRI-derived vascular density significantly enhances the diagnostic accuracy for MSRF in CKD patients. This comprehensive approach offers a promising non-invasive strategy for assessing renal fibrosis severity.

15 July 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
JHJia Huang
Jia Huang
YZYao Zhang
Yao Zhang
HPHuan Pu
Huan Pu
BSBin Sun
Bin Sun
XHXingyue Huang
Xingyue Huang
QZQing Zhou
Qing Zhou
Background/Objectives: Rectovaginal fistula (RVF) is a challenging condition that can substantially impair quality of life and often requires individualized surgical management. Accurate preoperative imaging is essential for identifying fistulous tracts, assessing pelvic floor involvement, and guiding surgical planning. However, conventional imaging modalities, including magnetic resonance imaging (MRI), may still have limitations in detecting small, occult, intermittently patent, or anatomically complex fistulas, particularly under static imaging conditions. This study aimed to evaluate the diagnostic performance of transperineal pelvic floor ultrasound (TPUS) combined with ultrasound contrast agent enema (UCAE) and its potential value in preoperative assessment of RVF. Methods: In this prospective single-center study, 62 women with surgically confirmed RVF were enrolled between January 2022 and April 2025. All patients underwent TPUS combined with UCAE before surgery, while subsets also underwent contrast-enhanced CT, contrast-enhanced MRI, or barium enema according to clinical indications. Imaging findings were compared with intraoperative findings as the reference standard. Fistula detection, morphological classification, size, anatomical location, pelvic floor injury assessment, and concordance between ultrasound-based surgical proposals and actual surgical procedures were systematically analyzed. Comparative analyses with conventional imaging modalities were performed based on available non-paired subgroups. Results: UCAE detected RVF in 60 of 62 patients, yielding a detection rate of 96.8%. In the available comparative cohort, UCAE demonstrated higher detection rates than conventional imaging modalities, particularly in small and complex fistulas. UCAE showed high agreement with intraoperative findings in terms of fistula morphology, size, and anatomical location. TPUS provided additional and complementary information regarding levator ani and anal sphincter injuries and yielded higher sensitivity and accuracy in pelvic floor injury assessment within the studied cohort. Ultrasound-based surgical proposals showed directional concordance with final intraoperative decisions in 88.7% of cases. No adverse events were observed during UCAE. Conclusions: TPUS combined with UCAE appears to be a safe and feasible preoperative imaging approach for RVF. By integrating fistula detection, anatomical classification, pelvic floor assessment, and surgical planning, this combined ultrasound approach may serve as a complementary imaging strategy to conventional imaging modalities, particularly for small or intermittently patent fistulas. Further multicenter studies and standardized imaging protocols are warranted to validate its clinical utility and generalizability.