Andres Annuk

Prof. Andres Annuk

Chair of Energy Application Engineering, Institute of Technology, Estonian University of Life Sciences
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2022 in Energy Reports
Verified
Journal Article
Open access
LOIY AL-GHUSSAINLOIY AL-GHUSSAIN
LOIY AL-GHUSSAIN
AAAdnan Darwish Ahmad
Adnan Darwish Ahmad
AAAhmad Abubaker
Ahmad Abubaker
KHKülli Hovi
Külli Hovi
Muhammed HassanMuhammed Hassan
Muhammed Hassan
AAAndres Annuk
Andres Annuk

25 October 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJian Chen
Jian Chen
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
Udaya DampageUdaya Dampage
Udaya Dampage
Mostafa RezaeiMostafa Rezaei
Mostafa Rezaei
SSSaleh H. Salmen
Saleh H. Salmen
AAAndres Annuk
Andres Annuk
To comply with electric power grid automation strategies, new cyber-security protocols and protection are required. What we now experience is a new type of protection against new disturbances namely cyber-attacks. In the same vein, the impact of disturbances arising from faults or cyber-attacks should be surveyed by network vulnerability criteria alone. It is clear that the diagnosis of vulnerable points protects the power grid against disturbances that would inhibit outages such as blackouts. So, the first step is determining the network vulnerable points, and then proposing a support method to deal with these outages. This research proposes a comprehensive approach to deal with outages by determining network vulnerable points due to physical faults and cyber-attacks. The first point, the network vulnerable points against network faults are covered by microgrids. As the second one, a new cyber-security protocol named multi-layer security is proposed in order to prevent targeted cyber-attacks. The first layer is a cyber-security-based blockchain method that plays a general role. The second layer is a cyber-security-based reinforcement-learning method, which supports the vulnerable points by monitoring data. On the other hand, the trend of solving problems becomes routine when no ambiguity arises in different sections of the smart grid, while it is far from a big network’s realities. Hence, the impact of uncertainty parameters on the proposed framework needs to be considered. Accordingly, the unscented transform method is modeled in this research. The simulation results illustrate that applying such a comprehensive approach can greatly pull down the probability of blackouts.

26 October 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
KAKHALID ALNOWIBET
KHALID ALNOWIBET
AAAndres Annuk
Andres Annuk
Udaya DampageUdaya Dampage
Udaya Dampage
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
During the last few years, attention has overwhelmingly focused on the integrated management of urban services and the demand of customers for locally-based supply. The rapid growth in developing smart measuring devices has made the underlying systems more observable and controllable. This exclusive feature has led the system designers to pursue the implementation of complex protocols to provide faster services based on data exchanges. On the other hand, the demands of consumers for locally-based supply could cause a disjunction and islanding behavior that demands to be dealt with by precise action. At first, keeping a centralization scheme was the main priority. However, the advent of distributed systems opened up new solutions. The operation of distributed systems requires the implementation of strong communication links to boost the existing infrastructure via smart control and supervision, which requires a foundation and effective investigations. Hence, necessary actions need to be taken to frustrate any disruptive penetrations into the system while simultaneously benefiting from the advantages of the proposed smart platform. This research addresses the detection of false data injection attacks (FDIA) in energy hub systems. Initially, a multi-hub system both in the presence of a microgrid (the interconnected smart energy hub-based microgrid system) and without it has been modeled for energy management in a way that allows them to cooperate toward providing energy with each other. Afterward, an FDIA is separately exerted to all three parts of the energy carrier including the thermal, water, and electric systems. In the absence of FDIA detection, the impact of FDIA is thoroughly illustrated on energy management, which considerably contributes to non-optimal operation. In the same vein, the intelligent priority selection based reinforcement learning (IPS-RL) method is proposed for FDIA detection. In order to model the uncertainty effects, the unscented transformation (UT) is applied in a stochastic framework. The results on the IEEE standard test system validate the system’s performance.

17 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
Seyedali MirjaliliSeyedali Mirjalili
Seyedali Mirjalili
Udaya DampageUdaya Dampage
Udaya Dampage
SSSaleh H. Salmen
Saleh H. Salmen
SOSami Al Obaid
Sami Al Obaid
AAAndres Annuk
Andres Annuk
The impressive furtherance of communication technologies has exhorted industrial companies to link-up these developments with their own abilities with the target of efficiency enhancement through smart supervision and control. With this in mind, the blockchain platform is a prospective solution for merging communication technologies and industrial infrastructures, but there are several challenges. Such obstacles should be addressed to effectively adopt this technology. One of the most recent challenges relative to adopting blockchain technology is the energy consumption of miners. Thus, providing an accurate approach that addresses the underlying cause of the problem will carry weight in the future. This work addresses managing the energy consumption of miners by using the advantage of distributed generation resources (DGRs). Along the same vein, it appears that achieving the optimal solution requires executing the modified reconfirmation of DGRs and miners (indeed, mining pool systems) in the smart grid. In order to perform this task, this article utilizes the Intelligent Priority Selection (IPS) method since this method is up to snuff for corporative allocation. In order to find practical solutions for this problem, the uncertainty is also modeled as a credible index highly correlated with the load and generation. All in all, it can be said that the outcome of this research study can help researchers in the field of enhancement of social welfare by using the proposed technology.

18 October 2021 in Electronics
Verified
Journal Article
Open access
PDF file
MRMian Rizwan
Mian Rizwan
Muhammad WaseemMuhammad Waseem
Muhammad Waseem
RLRehan Liaqat
Rehan Liaqat
MSMalik Intisar Ali Sajjad
Malik Intisar Ali Sajjad
Udaya DampageUdaya Dampage
Udaya Dampage
AAAndres Annuk
Andres Annuk
Renewable energy-based distributed generators (DGs) are gaining more penetration in modern grids to meet the growing demand for electrical energy. The anticipated techno-economic benefits of these eco-friendly resources require their judicious and properly sized allocation in distribution networks (DNs). The preeminent objective of this research is to determine the sizing and optimal placing of DGs in the condensed DN of a smart city. The placing and sizing problem is modeled as an optimization problem to reduce the distribution loss without violating the technical constraints. The formulated model is solved for a radial distribution system with a non-uniformly distributed load utilizing the selective particle swarm optimization (SPSO) algorithm. The intended technique decreases the power loss and perfects the voltage profile at the system’s nodes. MATLAB is used for the simulation, and the obtained results are also validated by the Electrical Transient Analysis Program (ETAP). Results show that placing optimally sized DGs at optimal system nodes offers a considerable decline in power loss with an improved voltage profile at the network’s nodes. Distribution system operators can utilize the proposed technique to realize the reliable operation of overloaded urban networks.

1 November 2021 in Energy Strategy Reviews
Verified
Journal Article
Open access
JCJian Chen
Jian Chen
KAKHALID ALNOWIBET
KHALID ALNOWIBET
AAAndres Annuk
Andres Annuk
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed