Yuya Ito

Mr. Yuya Ito

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
YNYuko Nakamura
Yuko Nakamura
THToru Higaki
Toru Higaki
FTFuminari Tatsugami
Fuminari Tatsugami
JZJian Zhou
Jian Zhou
ZYZhou Yu
Zhou Yu
KAKazuo Awai
Kazuo Awai
A deep learning–based reconstruction method can quantitatively and qualitatively improve the quality of abdominal CT images for the evaluation of hypovascular hepatic metastases. Purpose To evaluate the effect of a deep learning–based reconstruction (DLR) method on the conspicuity of hypovascular hepatic metastases on abdominal CT images. Materials and Methods This retrospe...

20 May 2026 in Japanese Journal of Radiology
Verified
Journal Article
Open access
YOYoshiyuki Ozawa
Yoshiyuki Ozawa
DTDaisuke Takenaka
Daisuke Takenaka
MNMasahiko Nomura
Masahiko Nomura
TUTakahiro Ueda
Takahiro Ueda
HKHirona Kimata
Hirona Kimata
YOYoshiharu Ohno
Yoshiharu Ohno
Purpose: Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. Materials and methods: Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. Results: The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion ( p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane ( p < 0.001). Conclusion: The DL-based motion correction algorithm named as ‘CLEAR Motion’ has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.

6 June 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
MNMasahiko Nomura
Masahiko Nomura
HKHirona Kimata
Hirona Kimata
YIYuya Ito
Yuya Ito
KFKenji Fujii
Kenji Fujii
NANaruomi Akino
Naruomi Akino
YOYoshiharu Ohno
Yoshiharu Ohno
Background/Objectives: To directly compare the capabilities of hybrid-type iterative reconstruction (IR) with the newly developed deep learning reconstruction (DLR) for the inner ear on high-definition CT (HDCT) obtained using the super-high-resolution (SHR) mode for external, middle and inner ear evaluations and diagnosis in patients with and without otologic diseases. Methods: Included in this study were 140 patients who had undergone HDCT, consisting of 32 otologic disease patients and 108 non-otologic disease patients, and 280 inner and middle ears and temporal bones were evaluated on a per ear analysis. Signal-to-noise ratios (SNRs) of the temporal bone surrounding the aural vestibule of the ear and in the vestibule as well as the cerebellar hemisphere, overall image and detailed evaluation of the visibility of anatomical landmarks in the middle and inner ear and temporal bone obtained with the two methods were assessed and statistically compared using the paired t-test or Wilcoxon’s signed-rank test. Then, receiver operating characteristic (ROC) analysis was performed to compare diagnostic performance between two reconstruction methods. Results: Each SNR of DLR was significantly higher than that of hybrid-type IR (p < 0.05). Overall image quality and detailed visualization of each anatomical structure obtained with DLR were significantly better than those obtained with hybrid-type IR (p < 0.05). The area under the curve of DLR had no significant difference with hybrid-type IR (p = 0.18). Conclusions: DLR has superior potential to hybrid-type IR for better image quality and visualization of anatomical landmarks in middle and inner ears and temporal bones on HDCT, although diagnostic performance was not affected in clinical practice.

9 July 2026 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
YOYoshiyuki Ozawa
Yoshiyuki Ozawa
DTDaisuke Takenaka
Daisuke Takenaka
MNMasahiko Nomura
Masahiko Nomura
TUTakahiro Ueda
Takahiro Ueda
HKHirona Kimata
Hirona Kimata
YOYoshiharu Ohno
Yoshiharu Ohno

29 August 2026 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
YOYoshiharu Ohno
Yoshiharu Ohno
YOYoshiyuki Ozawa
Yoshiyuki Ozawa
YSYusuke Seino
Yusuke Seino
HKHirona Kimata
Hirona Kimata
YIYuya Ito
Yuya Ito
ASAtsushi Suzuki
Atsushi Suzuki
Purpose: Metabolic syndrome (MetS) is screened for or assessed by manual waist circumference (WC) measurements or adipose tissue evaluation using supine multidetector CT (MDCT). Currently, upright MDCT was clinically established and tested for different clinical aims. The purpose of this study was to directly compare the utility of metabolic disorder assessments and the diagnosis of MetS among WC, upright MDCT, and supine MDCT in a Japanese health checkup test cohort. Materials and methods: This study cohort consisted of 47 consecutive subjects who underwent WC measurements, blood tests, upright MDCT, and supine MDCT on the same day. In each subject, the total fat area (TFA), subcutaneous fat area (SFA), visceral fat area (VFA), and visceral-to-subcutaneous fat ratio (VSR) were semi-automatically assessed using upright MDCT and supine MDCT data. To compare each index on both CTs, as well as manual WC measurements between the MetS and non-MetS groups, Student’s t -test was performed. Univariate regression analyses were performed to evaluate the relationship between each index and blood test results. Subsequently, receiver operating characteristic (ROC)-based positive tests were performed. Finally, the sensitivity, specificity, and accuracy were compared among all indexes from both CTs, and a manual WC measurement evaluation was conducted using McNemar’s test. Results: Some indices showed significant differences between two groups ( p < 0.05). All indices shows significant correlations with BMI, TG, HDL-cholesterol, uric acid, glucose, HbA1c, insulin, HOMA-IR, GOT (or AST), GPT (or ALT), or creatinine (manual WC measurement: − 0.58 ≤ r ≤ 0.87, p < 0.05; supine MDCT: − 0.61 ≤ r ≤ 0.84, p < 0.05; upright MDCT: − 0.64 ≤ r ≤ 0.91, p < 0.05). TFA and VFA on upright MDCT had significantly higher sensitivities than WCs determined from manual and supine MDCT as well as the VSR ( p < 0.05). Conclusion: Upright MDCT-derived adipose tissue indices showed preliminary potential for assessing metabolic syndrome, but larger prospective studies are needed to validate their clinical utility.