Kenji Fujii

Mr. Kenji Fujii

orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
KMK. Murayama
K. Murayama
SSS. Suzuki
S. Suzuki
HNH. Nagata
H. Nagata
JOJ. Oda
J. Oda
INIchiro Nakahara
Ichiro Nakahara
HTH. Toyama
H. Toyama
BACKGROUND AND PURPOSE: The newly developed ultra-high-resolution CT is equipped with a 0.25-mm detector, which has one-half the conventional section thickness, one-half the in-plane detector element width, and one-half the reconstructed pixel width compared with conventional-detector CT. Thus, the ultra-high-resolution CT scanner should provide better image quality for microvasculature than the conventional-detector CT scanners. This study aimed to determine whether ultra-high-resolution CT produces superior-quality images of the lenticulostriate arteries compared with conventional-detector CT. MATERIALS AND METHODS: From February 2017 to June 2017, thirteen patients with aneurysms (4 men, 9 women; mean age, 61.2 years) who underwent head CTA with both ultra-high-resolution CT and conventional-detector CT were enrolled. Two board-certified radiologists determined the number of all lenticulostriate arteries on the CTA coronal images of the MCA M1 segment reconstructed from 512 matrixes on conventional-detector CT and 1024 matrixes on ultra-high-resolution CT. RESULTS: There were statistically more lenticulostriate arteries identified on ultra-high-resolution CT (average, 2.85 ± 0.83; 95% CI, 2.509–3.183) than on conventional-detector CT (average, 2.17 ± 0.76; 95% CI, 1.866–2.480) (P = .009) in 16 of the total 26 MCA M1 segments. CONCLUSIONS: Improvements in lenticulostriate artery visualization were the result of the combined package of the ultra-high-resolution CT scanner plus the ultra-high-resolution scanning protocol, which includes higher radiation doses with lower than the national diagnostic reference levels and stronger adaptive iterative dose-reduction processing. This package for ultra-high-resolution CT is a simple, noninvasive, and easily accessible method to evaluate microvasculature such as the lenticulostriate arteries.

13 August 2015 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
KOKatia Orvin
Katia Orvin
DCD. Carrie
D. Carrie
GRG. Richardt
G. Richardt
WDW. Desmet
W. Desmet
AAA. Assali
A. Assali
RKRan Kornowski
Ran Kornowski

18 July 2022 in Neuroradiology
Verified
Journal Article
Closed access
PDF file
KMKazuhiro Murayama
Kazuhiro Murayama
ESEwoud J. Smit
Ewoud J. Smit
MPMathias Prokop
Mathias Prokop
YIYoshihiro Ikeda
Yoshihiro Ikeda
KFKenji Fujii
Kenji Fujii
HTHiroshi Toyama
Hiroshi Toyama

20 May 2026 in Japanese Journal of Radiology
Verified
Journal Article
Open access
YOYoshiyuki Ozawa
Yoshiyuki Ozawa
DTDaisuke Takenaka
Daisuke Takenaka
MNMasahiko Nomura
Masahiko Nomura
TUTakahiro Ueda
Takahiro Ueda
HKHirona Kimata
Hirona Kimata
YOYoshiharu Ohno
Yoshiharu Ohno
Purpose: Since the clinical application of computed tomography (CT), cardiac and respiratory motion artifacts have caused decreased image quality and reduced detection or quantitative or qualitative evaluation of lung parenchymal or vascular abnormalities on chest CT with lung window settings in patients with pulmonary diseases. Recently, a deep learning (DL)-based motion correction algorithm (CLEAR Motion) has been developed and clinically used for chest CT. We hypothesized that CLEAR Motion can significantly reduce motion artifacts on chest CT examinations relative to conventional chest CT images reconstructed without CLEAR Motion. The purpose of this study was to determine the utility of CLEAR Motion for image quality improvement in chest CT with lung window settings in patients with various pulmonary diseases. Materials and methods: Fifty-six consecutive patients with various thoracic diseases underwent non-electrocardiogram-gated chest helical CT examination using a 320-detector row CT and underwent reconstruction using the conventional reconstruction method and CLEAR Motion. To compare the quantitative image quality, the cardio-pulmonary edge distance (CPED) and slope (CPES) were measured on each CT scan in the axial plane. Comparing cardiac motion reduction capability, overall image quality, cardiac motion artifact, and region conspicuity were visually assessed in the lung window setting on the axial, coronal, and sagittal planes. The paired t-test and Wilcoxon signed-rank test were then performed. Results: The CPEDs and CPESs of the entire lung and left lung on CT with CLEAR Motion were significantly superior to those of CT without CLEAR Motion ( p < 0.001). The overall image quality, cardiac motion artifact, and region conspicuity on CT with CLEAR Motion were significantly higher than those without CLEAR Motion on each plane ( p < 0.001). Conclusion: The DL-based motion correction algorithm named as ‘CLEAR Motion’ has a potential to improve image quality on chest CT with lung window setting in patients with pulmonary diseases.

6 June 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
MNMasahiko Nomura
Masahiko Nomura
HKHirona Kimata
Hirona Kimata
YIYuya Ito
Yuya Ito
KFKenji Fujii
Kenji Fujii
NANaruomi Akino
Naruomi Akino
YOYoshiharu Ohno
Yoshiharu Ohno
Background/Objectives: To directly compare the capabilities of hybrid-type iterative reconstruction (IR) with the newly developed deep learning reconstruction (DLR) for the inner ear on high-definition CT (HDCT) obtained using the super-high-resolution (SHR) mode for external, middle and inner ear evaluations and diagnosis in patients with and without otologic diseases. Methods: Included in this study were 140 patients who had undergone HDCT, consisting of 32 otologic disease patients and 108 non-otologic disease patients, and 280 inner and middle ears and temporal bones were evaluated on a per ear analysis. Signal-to-noise ratios (SNRs) of the temporal bone surrounding the aural vestibule of the ear and in the vestibule as well as the cerebellar hemisphere, overall image and detailed evaluation of the visibility of anatomical landmarks in the middle and inner ear and temporal bone obtained with the two methods were assessed and statistically compared using the paired t-test or Wilcoxon’s signed-rank test. Then, receiver operating characteristic (ROC) analysis was performed to compare diagnostic performance between two reconstruction methods. Results: Each SNR of DLR was significantly higher than that of hybrid-type IR (p < 0.05). Overall image quality and detailed visualization of each anatomical structure obtained with DLR were significantly better than those obtained with hybrid-type IR (p < 0.05). The area under the curve of DLR had no significant difference with hybrid-type IR (p = 0.18). Conclusions: DLR has superior potential to hybrid-type IR for better image quality and visualization of anatomical landmarks in middle and inner ears and temporal bones on HDCT, although diagnostic performance was not affected in clinical practice.

9 July 2026 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
YOYoshiyuki Ozawa
Yoshiyuki Ozawa
DTDaisuke Takenaka
Daisuke Takenaka
MNMasahiko Nomura
Masahiko Nomura
TUTakahiro Ueda
Takahiro Ueda
HKHirona Kimata
Hirona Kimata
YOYoshiharu Ohno
Yoshiharu Ohno