Rosa M. Quispe-Siccha

Dr. Rosa M. Quispe-Siccha


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 October 2024 in Gels
Verified
Journal Article
Open access
PDF file
RQRosa M. Quispe-Siccha
Rosa M. Quispe-Siccha
OMOsvaldo I. Medina-Sandoval
Osvaldo I. Medina-Sandoval
AEAbraham Estrada-Tinoco
Abraham Estrada-Tinoco
JPJorge Alan Pedroza Perez
Jorge Alan Pedroza Perez
AMAdolfo Martínez-Tovar
Adolfo Martínez-Tovar
Juan Carlos Lopez-AlvarengaJuan Carlos Lopez-Alvarenga
Juan Carlos Lopez-Alvarenga
Polyvinyl alcohol (PVA) hydrogels have a wide range of applications in the pharmaceutical and biomedicine fields due to their exceptional biophysical properties. The study focuses on preparing and characterizing capsule-shaped PVA hydrogels to enhance their biocompatibility and porosity for controlled glucose release and cell proliferation. The hydrogels were prepared using different concentrations (Cs) and molecular weights (MWs) of PVA, with two different lengths, A (10 mm) and B (20 mm), to control glucose release over 60 min. The preparation process involved PVA gel preparation and PVA hydrogel formation. A total of 500 µL of glucose was injected into all dehydrated hydrogels in groups A and B. Glucose release was studied by immersing the hydrogels in saline at 37 °C with stirring at 500 rpm. The SUP-B15 cell line was grown in six A1 hydrogels for biocompatibility testing. The results indicate that all hydrogels remained stable at 37 °C without degrading. Those with a higher C and MW exhibited a denser and less porous structure, lower glucose storage capacity, and higher elongation at break. Significant differences in glucose release, diffusion speed, and flux were observed, which were more evident in A1 > A4, B1 > B4, and B1 > A1 over 60 min. A1 and B1 had higher values because their higher porosity distribution allowed glucose to diffuse more easily. B1, being larger, has more glucose due to its increased length. The cell growth response and viability at 48 h in contact with the hydrogels was similar to that of the control (4.5 × 105 cells/mL, 98.5% vs. 4.8 × 105 cells/mL, 99.7% viability), thus demonstrating biocompatibility. The hydrogels effectively released glucose over 60 min, with variations based on porosity, C, MW, and length, and demonstrated good biocompatibility with the cell line.

Lesli AlvarezLesli Alvarez
Lesli Alvarez
DCDaniel Castillo
Daniel Castillo
RSRosa María Quispe Siccha
Rosa María Quispe Siccha
APArgelia Perez
Argelia Perez
MAMaia Angelova
Maia Angelova
RFRuben Fossion
Ruben Fossion
Most gait parameters decrease with age and are even more importantly reduced with frailty. However, other gait parameters exhibit different or even opposite trends for aging and frailty, and the underlying reason is unclear. Literature focuses either on aging, or on frailty, and a comprehensive understanding of how biomechanical gait regulation evolves with aging and with frailty seems to be lacking. We monitored gait dynamics in young adults (19–29 years, n = 27, 59% women), middle-aged adults (30–59 years, n = 16, 62% women), and non-frail (>60 years, n = 15, 33% women) and frail older adults (>60 years, n = 31, 71% women) during a 160 m walking test using the triaxial accelerometer of the Zephyr Bioharness 3.0 device (Zephyr Technology, Annapolis, MD, USA). Frailty was evaluated using the Frail Scale (FS) and the Clinical Frailty Scale (CFS). We found that in non-frail older adults, certain gait parameters, such as cadence, were increased, whereas other parameters, such as step length, were decreased, and gait speed is maintained. Conversely, in frail older adults, all gait parameters, including gait speed, were decreased. Our interpretation is that non-frail older adults compensate for a decreased step length with an increased cadence to maintain a functional gait speed, whereas frail older adults decompensate and consequently walk with a characteristic decreased gait speed. We quantified compensation and decompensation on a continuous scale using ratios of the compensated parameter with respect to the corresponding compensating parameter. Compensation and decompensation are general medical concepts that can be applied and quantified for many, if not all, biomechanical and physiological regulatory mechanisms of the human body. This may allow for a new research strategy to quantify both aging and frailty in a systemic and dynamic way.

14 September 2020 in World Journal of Gastroenterology
Verified
Journal Article
Open access
EGElymir S Galvis-García
Elymir S Galvis-García
SSSergio Sobrino-Cossío
Sergio Sobrino-Cossío
ARArturo Reding-Bernal
Arturo Reding-Bernal
YCYesica Contreras-Marín
Yesica Contreras-Marín
KSKarina Solórzano-Acevedo
Karina Solórzano-Acevedo
RSRosa María Quispe Siccha
Rosa María Quispe Siccha
Experimental model standardizing polyvinyl alcohol hydrogel to simulate endoscopic ultrasound and endoscopic ultrasound-elastography

16 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
RIRoberto Márquez Islas
Roberto Márquez Islas
APArgelia Perez
Argelia Perez
RSRosa María Quispe Siccha
Rosa María Quispe Siccha
LSLaura Beatriz Salazar-Nieva
Laura Beatriz Salazar-Nieva
AGAugusto García-Valenzuela
Augusto García-Valenzuela
Today, visual classification of the degree of lipemia in blood samples is frequently performed in clinical laboratories. However, achieving standardization of this classification at low cost and with fewer resources is an objective that is still under development. In this work, a comparison is made between the visual inspection and optical measurements of blood plasma for quantifying lipemia. The plasma refractive index’s real part was measured using an Abbe refractometer and transmittance measurements were made at a 589 nm wavelength and wavelengths ranging from 320 to 1100 nm in the spectral region, respectively. Taking the slope of the transmittance spectrum at two specific wavelengths, it is possible to establish a more standardized selection criterion and implement it quickly using low-cost optical devices. Furthermore, using the proposed transmittance-spectrum-slope method, statistically significant differences (p < 0.05) were found between healthy blood samples and lipemia 1, 2, 3, and 4. However, there were no statistical differences between lipemia 1 and 2.

25 October 2023 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
APArgelia Perez
Argelia Perez
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
RQRosa M. Quispe-Siccha
Rosa M. Quispe-Siccha
MCMarco P. Colín-García
Marco P. Colín-García
The photoacoustic effect is an attractive tool for diagnosis in several biomedical applications. Analyzing photoacoustic signals, however, is challenging to provide qualitative results in an automated way. In this work, we introduce a dynamic modeling scheme of photoacoustic sensor data to classify blood samples according to their physiological status. Thirty-five whole human blood samples were studied with a state-space model estimated by a subspace method. Furthermore, the samples are classified using the model parameters and the linear discriminant analysis algorithm. The classification performance is compared with time- and frequency-domain features and an autoregressive-moving-average model. As a result, the proposed analysis can predict five blood classes: healthy women and men, microcytic and macrocytic anemia, and leukemia. Our findings indicate that the proposed method outperforms conventional signal processing techniques to analyze photoacoustic data for medical diagnosis. Hence, the method is a promising tool in point-of-care devices to detect hematological diseases in clinical scenarios. Graphical

LALesli Alvarez-Millán
Lesli Alvarez-Millán
Claudia LermaClaudia Lerma
Claudia Lerma
DCDaniel Castillo
Daniel Castillo
RSRosa María Quispe Siccha
Rosa María Quispe Siccha
APArgelia Perez
Argelia Perez
RFRuben Fossion
Ruben Fossion
The frailty syndrome is characterized by a decreased capacity to adequately respond to stressors. One of the most impaired physiological systems is the autonomous nervous system, which can be assessed through heart rate (HR) variability (HRV) analysis. In this article, we studied the chronotropic response (HR and HRV) to a walking test. We also analyzed HRV indices in rest as potential biomarkers of frailty. For this, a 160 m-walking test and two standing rest tests (before and after the walking) were performed by young (19–29 years old, n = 21, 57% women), middle-aged (30–59 years old, n = 16, 62% women), and frail older adults (>60 years old, n = 28, 40% women) and non-frail older adults (>60 years old, n = 15, 71% women), classified with the FRAIL scale and the Clinical Frailty Scale (CFS). Frequency domain parameters better allowed to distinguish between frail and non-frail older adults (low-frequency power LF, high-frequency power HF (nu), LF/HF ratio, and ECG-derived respiration rate EDR). Frail older adults showed an increased HF (nu) and EDR and a reduced LF (nu) and LF/HF compared to non-frail older adults. The increase in HF (nu) could be due to a higher breathing effort. Our results showed that a walk of 160 m is a sufficient cardiovascular stressor to exhibit an attenuated autonomic response in frail older adults. Several HRV indices showed to be potential biomarkers of frailty, being LF (nu) and the time required to reach the maximum HR the best candidates.