Roberto Giovanni Ramírez-Chavarría

Dr. Roberto Giovanni Ramírez-Chavarría

Instituto de Ingeniería, Universidad Nacional Autónoma de México, Mexico City, Ciudad de México, Mexico
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2022 in Journal of Environmental Chemical Engineering
Verified
Journal Article
Closed access
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
ECElizabeth Castillo-Villanueva
Elizabeth Castillo-Villanueva
BABryan E. Alvarez-Serna
Bryan E. Alvarez-Serna
JCJulián Carrillo-Reyes
Julián Carrillo-Reyes
RRRosa María Ramírez-Zamora
Rosa María Ramírez-Zamora
LALuis Alvarez-Icaza
Luis Alvarez-Icaza

1 June 2018 in Electrochimica Acta
Verified
Journal Article
Closed access
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
CSC. Sánchez-Pérez
C. Sánchez-Pérez
DMD. Matatagui
D. Matatagui
NQN. Qureshi
N. Qureshi
APAdolfo Perez-Garcia
Adolfo Perez-Garcia
JRJoselin Hernandez Ruiz
Joselin Hernandez Ruiz

5 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
CSCelia Sanchez-Perez
Celia Sanchez-Perez
LRLuisa Romero-Ornelas
Luisa Romero-Ornelas
EREva Ramon-Gallegos
Eva Ramon-Gallegos
Impedance measurement is a common technique to characterize and detect the electrical properties of biological cells. However, to decode the underlying physical processes, it requires complex electrical models alongside prior knowledge of the sample under study. In this work, we introduce an attractive label-free method for sensing biological cells in suspension based on the measurement of electrical impedance and the distribution of relaxation times (DRT) model. The DRT maps impedance data from the frequency-domain to a time-constant-domain spectrum (TCDS) being a useful and robust method for data analysis. We perform impedance measurements in the range from 1 kHz to 1 MHz to obtain the TCDS for sensing mimic samples as well as HeLa cells in suspension. Results show that the TCDS can be seen as an electrical fingerprint for the sample, as it can decode useful information about the composition and structure with high sensitivity and resolution.

7 April 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
ECElizabeth Castillo-Villanueva
Elizabeth Castillo-Villanueva
BABryan E Alvarez-Serna
Bryan E Alvarez-Serna
JCJulián Carrillo-Reyes
Julián Carrillo-Reyes
LTLizeth Torres
Lizeth Torres
LALuis Alvarez-Icaza
Luis Alvarez-Icaza
The development of sensitive and affordable testing devices for infectious diseases is essential to preserve public health, especially in pandemic scenarios. In this work, we have developed an attractive analytical method to monitor products of genetic amplification, particularly the loop-mediated isothermal amplification reaction (RT-LAMP). The method is based on electrochemical impedance measurements and the distribution of relaxation times model, to provide the so-called time-constant-domain spectroscopy (TCDS). The proposed method is tested for the SARS-CoV-2 genome, since it has been of worldwide interest due to the COVID-19 pandemic. Particularly, once the method is calibrated, its performance is demonstrated using real wastewater samples. Moreover, we propose a simple classification algorithm based on TCDS data to discriminate among positive and negative samples. Results show how a TCDS-based method provides an alternative mechanism for label-free and automated assays, exhibiting robustness and specificity for genetic detection.

25 October 2023 in Medical & Biological Engineering & Computing
Verified
Journal Article
Open access
PDF file
APArgelia Perez
Argelia Perez
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
RQRosa M. Quispe-Siccha
Rosa M. Quispe-Siccha
MCMarco P. Colín-García
Marco P. Colín-García
The photoacoustic effect is an attractive tool for diagnosis in several biomedical applications. Analyzing photoacoustic signals, however, is challenging to provide qualitative results in an automated way. In this work, we introduce a dynamic modeling scheme of photoacoustic sensor data to classify blood samples according to their physiological status. Thirty-five whole human blood samples were studied with a state-space model estimated by a subspace method. Furthermore, the samples are classified using the model parameters and the linear discriminant analysis algorithm. The classification performance is compared with time- and frequency-domain features and an autoregressive-moving-average model. As a result, the proposed analysis can predict five blood classes: healthy women and men, microcytic and macrocytic anemia, and leukemia. Our findings indicate that the proposed method outperforms conventional signal processing techniques to analyze photoacoustic data for medical diagnosis. Hence, the method is a promising tool in point-of-care devices to detect hematological diseases in clinical scenarios. Graphical

28 June 2021 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
RRRoberto Giovanni Ramírez-Chavarría
Roberto Giovanni Ramírez-Chavarría
BABryan E Alvarez-Serna
Bryan E Alvarez-Serna
MSMaarten Schoukens
Maarten Schoukens
LALuis Alvarez-Icaza
Luis Alvarez-Icaza
A data-driven scheme for modeling electrical impedance in biosensors is presented by a subspace method working with the singular value decomposition of structured voltage and current data. Contrary to the classical electrical impedance spectroscopy (EIS) methods, our scheme uses simple instrumentation, works in time-domain, provides fast results, and does not require semi-empirical assumptions to retrieve structured models from data. We show how data-driven models exhibit a close relationship with lumped-element circuits, encoding dielectric and conductive properties detected by the sensor in the range from 10 kHz up to 10 MHz. Performance results are shown for calibration networks and two case studies: (i) a buffer solution, and (ii) a biological cell suspension. Finally, the viability of the scheme is discussed when compared with the classical EIS method.