This study evaluates the feasibility of using asphalt concrete as an impermeable core material for rockfill dams under tropical conditions. Laboratory testing and numerical modeling were conducted to assess the hydraulic and mechanical performance of asphalt concrete mixtures produced with locally available aggregates in Thailand. Asphalt mixtures were designed using the Marshall method with asphalt binder contents of 6% and 7% and target air void contents between 1-4%. Laboratory testing included permeability testing, Marshall stability testing, and triaxial compression tests to determine hydraulic conductivity, shear strength parameters, and deformation characteristics. Results show that asphalt concrete mixtures with air void contents below 1% exhibit extremely low permeability, with hydraulic conductivity on the order of 10⁻¹¹–10⁻¹² m/s, satisfying requirements for impervious dam cores. Triaxial compression tests yielded cohesion values between 97-572 kPa and friction angles ranging from 31° to 52°, indicating adequate shear resistance. Numerical simulations performed using GeoStudio compared rockfill dams with asphalt concrete cores and conventional clay cores. The results demonstrate that a 0.5‑m‑thick asphalt concrete core provides comparable seepage control and slope stability while requiring significantly smaller material volume. The findings suggest that asphalt concrete cores represent a technically feasible and economically advantageous alternative to clay cores, particularly in regions where suitable clay materials are limited.
This study investigated the potential use of asphalt concrete produced with locally sourced limestone and granite aggregates as an impervious core material in rockfill dams. An independent laboratory program evaluated 16 mixture conditions comprising two aggregate types, asphalt cement contents of 6% and 7%, and nominal target air-void contents of 1–4%. Marshall, hydraulic-conductivity, and consolidated-undrained triaxial tests were conducted to characterize the mixtures. The reported hydraulic conductivity ranged from 2.9549 × 10−10 to 3.8887 × 10−5 cm/s, while effective cohesion and friction angle ranged from 165.7 to 540.3 kPa and 34.07° to 55.61°, respectively. Four core-property datasets corresponding to a 2% target air-void content were evaluated using two-dimensional GeoStudio analyses under steady-state and rapid-drawdown conditions. Steady-state seepage discharge ranged from 1.967 × 10−9 to 6.7191 × 10−6 m3/s, with downstream global factors of safety of 2.209–2.215. The upstream global factor of safety at Day 7 of rapid drawdown was 2.041 for all four datasets. The granite mixture containing 7% asphalt cement and a target air-void content of 2% (Granite AC7% AV2%) was subsequently selected as a representative, rather than optimal, core-property dataset for a separate steady-state geometry comparison. Relative to the conventional clay-core baseline, a 0.50-m-thick asphalt concrete core with shell slopes of 1 V:1.5 H and 1 V:1.4 H reduced the calculated embankment volume per unit dam length by 21.11% and 24.83%, respectively, with corresponding global factors of safety of 1.655 and 1.557. A supplementary rapid-drawdown assessment of the steepest alternative yielded an upstream global factor of safety of 1.473 at Day 6, the lowest among the reported daily results. The findings provide comparative laboratory data and case-specific numerical results for preliminary assessment of asphalt concrete dam cores. Hydraulic acceptance and field-scale suitability are not established, and further experimental verification and numerical sensitivity assessments remain necessary before application.