Silviu Brad

Prof. Dr. Silviu Brad

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2020 in Materials
Verified
Journal Article
Open access
PDF file
APAdelina Popa
Adelina Popa
CRISTINA ADRIANA DEHELEANCRISTINA ADRIANA DEHELEAN
CRISTINA ADRIANA DEHELEAN
HCHoria Calniceanu
Horia Calniceanu
Claudia G WatzClaudia G Watz
Claudia G Watz
SBSilviu Brad
Silviu Brad
CSCamelia Alexandrina Szuhanek
Camelia Alexandrina Szuhanek
Background: Orthodontic mini-implant failure is a debatable subject in clinical practice. However, the most important parameter to evaluate the success rate of mini-implant is the primary stability, which is mainly influenced by cortical bone thickness (CBT) and insertion angle. Materials and methods: Three-dimensional finite element models of the maxilla were created and a custom-made, self-drilling, tapered mini-implant was designed. For the pull-out test, 12 simulations were performed, sequentially increasing the thickness of the cortical bone (1, 1.5 and 2 mm) and the insertion angle (30°, 60°, 90°, 120°). For the force analysis, 24 simulations were performed using an experimental orthodontic traction force of 2 N both in the horizontal and vertical axis. Results: Insertion angle and CBT have significant impact on force reaction values (p < 0.05). Cortical bone stress had the lowest value when the mini-implant had a 30° insertion angle and the highest value when the implant had a 120° insertion angle, while the CBT was 1 mm. Cortical bone stress had the lowest value with an insertion angle of 90° and the highest value when the implant was inserted at an angle of 30°, while the CBT was 2 mm independent of the force direction. Regarding the biosafety profile of the mini-implant alloy, the present results reveal that the custom-made mini-implant presents good biocompatibility. Conclusions: When the CBT is reduced, we recommend inclined insertion while, when the CBT is appropriate, perpendicular insertion is advised.

22 May 2023 in Brain Sciences
Verified
Journal Article
Open access
PDF file
IAIancu Aida
Iancu Aida
BFBuleu Florina
Buleu Florina
DCDana Simona Chita
Dana Simona Chita
ATAdrian Tutelca
Adrian Tutelca
Raluca TudorRaluca Tudor
Raluca Tudor
SBSilviu Brad
Silviu Brad
Background: The standard reperfusion therapy for acute ischemic stroke (AIS) is considered to be thrombolysis, but its application is limited by the high risk of hemorrhagic transformation (HT). This study aimed to analyze risk factors and predictors of early HT after reperfusion therapy (intravenous thrombolysis or mechanical thrombectomy). Material and methods: Patients with acute ischemic stroke who developed HT in the first 24 h after receiving rtPA thrombolysis or performing mechanical thrombectomy were retrospectively reviewed. They were divided into two groups, respectively, the early-HT group and the without-early-HT group based on cranial computed tomography performed at 24 h, regardless of the type of hemorrhagic transformation. Results: A total of 211 consecutive patients were enrolled in this study. Among these patients, 20.37% (n = 43; age: median 70.00 years; 51.2% males) had early HT. Multivariate analysis of independent risk factors associated with early HT found that male gender increased the risk by 2.7-fold, the presence of baseline high blood pressure by 2.4-fold, and high glycemic values by 1.2-fold. Higher values of NIHSS at 24 h increased the risk of hemorrhagic transformation by 1.18-fold, while higher values of ASPECTS at 24 h decreased the risk of hemorrhagic transformation by 0.6-fold. Conclusions: In our study, male gender, baseline high blood pressure, and high glycemic values, along with higher values of NIHSS were associated with the increased risk of early HT. Furthermore, the identification of early-HT predictors is critical in patients with AIS for the clinical outcome after reperfusion therapy. Predictive models to be used in the future to select more careful patients with a low risk of early HT need to be developed in order to minimize the impact of HT associated with reperfusion techniques.

24 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LSLaura Andreea Schiller
Laura Andreea Schiller
Horia Mihail BarbuHoria Mihail Barbu
Horia Mihail Barbu
SIStefania Andrada Iancu
Stefania Andrada Iancu
SBSilviu Brad
Silviu Brad
Background: The purpose of this study is to analyze if there is any statistical correlation between the surgery’s complexity (easy to difficult—depending on the anatomical conditions) and the patient’s sex, type of edentulism, and left or right side of the maxilla. Methods: Cone beam computed tomography records of 1192 maxillary sinuses were evaluated, measured, and statistically analyzed with respect to patient sex, type of edentulism, and left or right side, taking into consideration Wen’s proposed sinus septum classification. Results: Our research suggests that most sinus augmentation procedures in patients presenting antral septum fall into the Moderate A category (31.94%) and that there is not a correlation between the surgery’s complexity (easy to difficult) and the patient’s sex, type of edentulism and left or right side of the maxilla. Conclusion: We suggest a minor modification to Wen’s classification in view of the fact that our findings revealed a combination of medio-lateral and antero-posterior septa that we could not classify in one of the existing categories.

1 January 2020 in Case Reports in Dentistry
Verified
Journal Article
Open access
PDF file
LSLaura Andreea Schiller
Laura Andreea Schiller
ASAlbert Cristian Schiller
Albert Cristian Schiller
ASAdalbert Schiller
Adalbert Schiller
ADAida Gabriela Dascalu
Aida Gabriela Dascalu
SBSilviu Brad
Silviu Brad
The objective of this clinical case is to evaluate if bone augmentation procedures can be successful in a patient with altered bone metabolism due to a systemic disease: acromegaly. Two guided bone regeneration procedures were made on the same patient: horizontal ridge augmentation with lateral wall approach sinus graft of the left maxilla and horizontal ridge augmentation of the front left maxilla. CBCT assessment of the new formed bone was made after a minimum of nine months and dental implants were placed. The results show that bone augmentation procedures can be successful in a patient with acromegaly, after pituitary adenoma removal, when autologous bone is not included in the grafting procedure.

18 February 2024 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
IAIancu Aida
Iancu Aida
Raluca TudorRaluca Tudor
Raluca Tudor
DCDana simona Chita
Dana simona Chita
CJCatalin Juratu
Catalin Juratu
ATAnca Tudor
Anca Tudor
SBSilviu Brad
Silviu Brad
Study design: Mechanical thrombectomy (MT) via the transbrachial approach (TBA) is a very rare option used in cases of patients with aortic pathologies and acute ischemic stroke (AIS) due to the insufficient evidence in the literature, the difficulty from a technical point of view and the result of this technique influenced by the complications that frequently accompany it. Background: Only a few cases of patients with aortic pathologies and acute ischemic stroke where MT via TBA were reported in the literature, and its application in the emergency management of AIS has still not been dealt with in detail. Objectives: Out of a need to clarify and clearly emphasize the effectiveness of this approach in emergency MT via TBA in patients with AIS and aortic pathologies, this literature review and case report has the following objectives: the first one is the presentation of an emergency MT via transbrachial approach performed in a 44-year-old patient with AIS and diagnosed aortic coarctation during transfemural approach (TFA), with successful reperfusion in our department and the second one is to review the cases reports of patients with different aortic pathologies and AIS reperfusion therapy performed by MT via TBA from the literature. Methods: A total of nine cases (one personal case and eight published cases) were revised in terms of aortic pathologies type, reperfusion therapy type, and the complication of both mechanical thrombectomy and local transbrachial approach. Results: Mechanical thrombectomy through the transbrachial approach was the first choice in more than half of these cases (55.55%, n = 5 cases) in the treatment of acute ischemic stroke in the presence of previously diagnosed aortic pathologies. In one-third of all cases (33.33%, n = 3, our case and 2 case reports from the literature), the transbrachial approach was chosen after attempting to advance the guiding catheter through the transfemoral approach and intraprocedural diagnosis of aortic pathology. In only one case, after an ultrasound evaluation of the radial artery that showed a monophasic flow, MT was performed via TBA. Local transbrachial complication was reported in one case, and in two other cases, it was not stated if there were such complications. Hemorrhagic transformation of AIS was reported in two cases that underwent MT-only cerebral reperfusion via TBA, one with acute aortic dissection type A and our case of previously undiagnosed aortic coarctation. In the cases in whom short and long-term follow-up was reported, the outcome of treatment, which was not exclusively endovascular (77.77% cases with only MT and 33.33% with association of first thrombolysis and after MT), was good (six from nine patients). In two case reports, the outcomes were not stated, and one patient died after a long hospitalization in the intensive care unit from respiratory complications (our patient). Conclusions: Being a clinical emergency, acute ischemic stroke requires urgent medical intervention. In patients with aortic pathologies, where acute ischemic stroke emergency care is a challenge, mechanical thrombectomy via the transbrachial approach is a safe alternative method for cerebral reperfusion.

9 April 2025 in Romanian Journal of Oral Rehabilitation
Verified
Journal Article
Open access
RBRomina Georgiana Bita
Romina Georgiana Bita
SBSilviu Brad
Silviu Brad
IPIasmina-Alexandra Predescu
Iasmina-Alexandra Predescu
RMRaluca-Adriana Milutinovici
Raluca-Adriana Milutinovici
CSCamelia Alexandrina Szuhanek
Camelia Alexandrina Szuhanek
Stefania DinuStefania Dinu
Stefania Dinu
Aim of the study According to the World Health Organization, malocclusion is one of children's most common dental problems. Many children visit dentists early, requiring long-term treatment due to misaligned teeth. Silicone aligners represent modern alternative treatments to traditional orthodontic appliances due to the soft and flexible material from which they are made and the effectiveness they have proven over the years. The present study aims to investigate the biosafety profile of four silicone aligners (A1, A2, A3, and A4) from three different manufacturers by in vitro and in ovo assays. Materials and methods In this study, four silicone aligners were immersed in artificial saliva at a neutral pH for seven days. Subsequently, four different dilutions (1:8, 1:4, 1:2, and 1:1) were then prepared and tested in vitro on HaCaT and JB6 Cl 105 41-5a cell lines to analyze their effects on cell viability and potential irritant effect on the blood vessels of the chorioallantoic membrane. Results The results showed that after 48 hours of exposure to A1, A2, A3, and A4, the viability of HaCaT and JB6 Cl 105 41-5a cell lines remained over 70%, which demonstrates, according to ISO Standard 10993-5:2009, that these aligners are not considered cytotoxic. Additionally, regarding cell morphology, the four dental devices did not induce significant changes in the appearance of the nuclei. Furthermore, the potential irritant effect of A1, A2, A3, and A4 on the chorioallantoic membrane was evaluated. It was observed that they did not produce changes in the blood vessels, with an irritation score of 0.070, categorizing them as non-irritant agents. Conclusions This study confirms the biosafety profile of the four dental aligners: A1, A2, A3, and A4.