Yang Zhao

Dr. Yang Zhao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YZYang Zhao
Yang Zhao
ZSZhongxia Shang
Zhongxia Shang
YLYongfu Li
Yongfu Li
High input impedance, low noise, high common mode rejection ratio (CMRR), and ultralow power are the most important performance indicators in the design of analog front-end (AFE) for wearable biomedical sensors. This paper presents a fully differential difference amplifier (FDDA) based AFE that employs DC-coupled input stage to increase the input impedance and improve CMRR. A parasitic capacitor reuse technique is proposed to improve the noise/area efficiency and CMRR. An on-body DC bias scheme is introduced to deal with the input DC offset. Implemented in 0.35μm CMOS process with an area of 0.405mm $^2$ , the proposed AFE consumes 0.9μW at 1.8V and shows excellent noise effective factor of 2.55, and CMRR of 76dB. Experiment shows the proposed AFE not only picks up clean ECG signal with electrodes placed as close as 2cm under both resting and walking conditions, but also obtain the distinct α-wave after eye blink from EEG recording.

7 June 2022 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
YZYang Zhao
Yang Zhao
YLYongfu Li
Yongfu Li
This brief presents an overview of current trends in the level-crossing based even-driven systems for wireless sensors in AIoT applications. We show that orders of magnitude improvement in power consumption is possible with this promising low-power technique if we have a good understanding of the operation principle of the system, the ways of processing LC samples, and the selection of LC-ADC topology. We also present the research direction to extend the event-driven system for wide applications.

20 June 2024 in Brain‐X
Verified
Journal Article
Open access
LWLongchun Wang
Longchun Wang
YSYanxing Suo
Yanxing Suo
JWJiahao Wang
Jiahao Wang
XWXuanqi Wang
Xuanqi Wang
KXKai Xue
Kai Xue
JLJing-Quan Liu
Jing-Quan Liu
High‐density neural recordings with superior spatiotemporal resolution powerfully unveil cellular‐scale neural communication, showing great promise in neural science, translational medicine, and clinical applications. To achieve such, many design and fabrication innovations enhanced the electrode, chip, or both for biocompatibility improvement, electrical performance upgrade, and size miniaturization, offering several thousands of recording sites. However, an enormous gap exists along the trajectory toward billions of recording sites for brain scale resolution, posing many more design challenges. This review tries to find possible insight into mitigating the gap by discussing the latest progress in high‐density electrodes and chips for neural recordings. It emphasizes the design, fabrication, bonding techniques, and in vivo performance optimization of high‐density electrodes. It discusses the promising opportunities for circuit‐level and architecture‐level multi‐channel chip design innovations. We expect that joint effort and close collaboration between high‐density electrodes and chips will pave the way to high‐resolution neural recording tools supporting cutting‐edge neuroscience discoveries and applications.

22 June 2021 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
QCQiao Cai
Qiao Cai
XXXinzi Xu
Xinzi Xu
YZYang Zhao
Yang Zhao
LYLiang Ying
Liang Ying
YLYongfu Li
Yongfu Li
YLYong Lian
Yong Lian
An event-driven system generates samples only when a predefined event is triggered, thus the power consumption tracks the input activities leading to significant savings in power for wearable sensors. In this brief, we presented an event-driven artificial neural network (ANN) core for cardiac arrhythmia classifier (CAC). The proposed data alignment mechanism allows seamless cooperation between the ANN CAC core and the event-driven clockless analog front-end. Measurement results show that the ANN CAC core consumes merely 1.3μW dynamic power at heart rate of 75bpm with a clock frequency of 250kHz a 1.5V supply voltage. Fabricated in 0.18μm, the core occupies 0.75mm 2 with minimum 1.8 μJ/classification, achieving average classification accuracy of 98% for all 5 types of heart beats as defined in the AAMI.

1 June 2020 in IEEE Transactions on Circuits and Systems II: Express Briefs
Verified
Journal Article
Closed access
ZSZhongxia Shang
Zhongxia Shang
YZYang Zhao
Yang Zhao
WGWei Gou
Wei Gou
Weihua LiuWeihua Liu
Weihua Liu
YLYongfu Li
Yongfu Li
This paper presents a boost converter with high efficiency for thermo-electrical energy generator (TEG). An on-time calibration based pulse skipping modulation (OTC-PSM) scheme is proposed to reduce the power of the controller. A hardware-efficient maximum power point tracking (MPPT) circuit is introduced for the constant internal resistance source of TEG. The proposed design has been implemented in a standard 180 nm CMOS process, achieving a high efficiency of 83.9% at 120mV input voltage and output power of 600 μW. The proposed OTC-PSM scheme saves considerable power in achieving high efficiency as well as low output ripple. Also, the proposed MPPT is simple and easy to implement for low cost.

28 July 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
XXXinzi Xu
Xinzi Xu
QCQiao Cai
Qiao Cai
YZYang Zhao
Yang Zhao
GWGuoxing Wang
Guoxing Wang
LZLiebin Zhao
Liebin Zhao
YLYongfu Li
Yongfu Li
Wearable electrocardiogram (ECG) device is an effective tool for managing cardiovascular diseases. This paper presents a low power clinician-like cardiac arrhythmia watchdog (CAW) for wearable ECG devices. The CAW is based on a novel P-QRS-T detection algorithm that makes use of clinical features to identify abnormalities. Implemented in 0.18μm CMOS process, the CAW consumes 2.66µW for 80bpm heart rate at 1.2V supply with an area of 0.578mm2. Verified on QT database, the average sensitivity /positive predictivity for P-wave, QRS complex and T-wave are over 93.39%/88.55%, 99.69%/99.48%, and 97.13%/93.18% respectively, across over 190000 beats. It shows over 99.8% arrhythmia detection accuracy for 43 subjects evaluated on MIT-BIH database.