Yaiza Montes-Cebrián

Mrs. Yaiza Montes-Cebrián

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
YMYaiza Montes-Cebrián
Yaiza Montes-Cebrián
LRLorena del Torno-De Román
Lorena del Torno-De Román
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
SMShelley Minteer
Shelley Minteer
JEJuan Pablo Esquivel
Juan Pablo Esquivel

6 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YMYaiza Montes-Cebrián
Yaiza Montes-Cebrián
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
GRGisela Ruiz-Vega
Gisela Ruiz-Vega
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
MPManuel Puig
Manuel Puig
PMPere Miribel-Catala
Pere Miribel-Catala
Considerable efforts are made to develop Point-of-Care (POC) diagnostic tests. POC devices have the potential to match or surpass conventional systems regarding time, accuracy, and cost, and they are significantly easier to operate by or close to the patient. This strongly depends on the availability of miniaturized measurement equipment able to provide a fast and sensitive response. This paper presents a low-cost, portable, miniaturized USB-powered potentiostat for electrochemical analysis, which has been designed, fabricated, characterized, and tested against three forms of high-cost commercial equipment. The portable platform has a final size of 10.5 × 5.8 × 2.5 cm, a weight of 41 g, and an approximate manufacturing cost of $85 USD. It includes three main components: the power module which generates a stable voltage and a negative supply, the front-end module that comprises a dual-supply potentiostat, and the back-end module, composed of a microcontroller unit and a LabVIEW-based graphic user interface, granting plug-and-play and easy-to-use operation on any computer. The performance of this prototype was evaluated by detecting chronoamperometrically horseradish peroxidase (HRP), the enzymatic label most widely used in electrochemical biosensors. As will be shown, the miniaturized platform detected HRP at concentrations ranging from 0.01 ng·mL−1 to 1 µg·mL−1, with results comparable to those obtained with the three commercial electrochemical systems.

27 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YMYaiza Montes-Cebrián
Yaiza Montes-Cebrián
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
MPManuel Puig
Manuel Puig
PMPere Miribel-Catala
Pere Miribel-Catala
In this work, we present a self-powered electronic reader (e-reader) for point-of-care diagnostics based on the use of a fuel cell (FC) which works as a power source and as a sensor. The self-powered e-reader extracts the energy from the FC to supply the electronic components concomitantly, while performing the detection of the fuel concentration. The designed electronics rely on straightforward standards for low power consumption, resulting in a robust and low power device without needing an external power source. Besides, the custom electronic instrumentation platform can process and display fuel concentration without requiring any type of laboratory equipment. In this study, we present the electronics system in detail and describe all modules that make up the system. Furthermore, we validate the device’s operation with different emulated FCs and sensors presented in the literature. The e-reader can be adjusted to numerous current ranges up to 3 mA, with a 13 nA resolution and an uncertainty of 1.8%. Besides, it only consumes 900 µW in the low power mode of operation, and it can operate with a minimum voltage of 330 mV. This concept can be extended to a wide range of fields, from biomedical to environmental applications.

10 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
YMYaiza Montes-Cebrián
Yaiza Montes-Cebrián
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
PMPere Miribel-Catala
Pere Miribel-Catala
A novel self-powered point-of-care low-power electronics approach for galvanic cell-based sample concentration measurement is presented. The electronic system harvests and senses at the same time from the single cell. The system implements a solution that is suitable in those scenarios where extreme low power is generated from the fuel cell. The proposed approach implements a capacitive-based method to perform a non-linear sweep voltammetry to the cell, but without the need to implement a potentiostat amplifier for that purpose. It provides a digital-user readable result without the need for external non-self-powered devices or instruments compared with other solutions. The system conception was validated for a particular case. The scenario consisted of the measurement of a NaCl solution as the electrolyte, which was related to the conductivity of the sample. The electronic reader continuously measured the current with a transfer function gain of 1.012 V mA−1. The overall system exhibited a maximum coefficient of variation of 6.1%, which was an improvement compared with the state-of-the-art. The proof of concept of this electronics system was validated with a maximum power consumption of 5.8 μW using commercial-off-the-self parts.

13 October 2020 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AÁAlbert Álvarez-Carulla
Albert Álvarez-Carulla
YMYaiza Montes-Cebrián
Yaiza Montes-Cebrián
MPManuel Puig
Manuel Puig
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
PMPere Miribel-Catala
Pere Miribel-Catala
Current research about battery-less fuel cell- based Point-of-Care (POC) devices study energy extraction and the measurement separately. We purpose a self-powered architecture that extracts energy efficiently from a fuel cell and performs a measurement simultaneously. The prototype uses a discrete Power Management Unit (PMU)-based architecture with a power consumption lower than 36 μW. We have tested it with ethanol, lactate, and methanol-based fuel cells, being able to perform a fuel concentration measurement while it extracts energy from fuel cells. The solution exhibited a minimum efficiency and maximum start-up time for the ethanol, lactate, and methanol-based fuel cells of 80% and 12 s. The architecture applies to other fuel cells, and the results show how this solution can help us face the current POC's autonomy challenge.

1 November 2018
Verified
Conference Paper
Closed access
YMYaiza Montes-Cebrián
Yaiza Montes-Cebrián
AAA. Alvarez-Carulla
A. Alvarez-Carulla
JCJordi Colomer-Farrarons
Jordi Colomer-Farrarons
MPManuel Puig
Manuel Puig
JLJ. Lopez-Sanchez
J. Lopez-Sanchez
PMP. Miribel-Catala
P. Miribel-Catala
In this work, we present a Self-Powered Event Detection platform to sample biological agents. The proposed low-power system does not use a conventional battery, electronics are powered by a Biological Fuel Cell (BFC). BFCs are electrochemical devices that use biological agents to transform chemical to electrical energy. Furthermore, BFCs can power the sensing electronics while they act as a sensor. We demonstrate the feasibility of this discrete approach with the simulation of the self-powered system fully adaptable to any type of BFC. In this case, we validate the electronic platform with a glucose BFC, detecting three glucose levels (5mM, 7mM and 10mM). The designed system detects sample concentration measuring the current provided by the BFC and gives a qualitative result. The advantages of the presented approach can be extended to any kind of BFC, by measuring different types of analytes. In addition, this innovative concept opens the door to new emerging technologies. Due to the simple architecture of the designed system, it can be implemented on flexible and printable plastic substrates.