Image texture is a complex visual perception. With the ever-increasing spatial resolution of remotely sensed data, the role of image texture in image classification has increased. Current approaches to image texture analysis rely on a single band of spatial information to characterize texture. This paper presents a multiscale approach to image texture where first and second-order statistical measures were derived from different sizes of processing windows and were used as additional information in a supervised classification. By using several bands of textural information processed with different window sizes (from 5×5 to 15×15) the main forest stands in the image were improved up to a maximum of 40%. A geostatistical analysis indicated that there was no single window size that would adequately characterize the range of textural conditions present in this image. A number of different statistical texture measures were compared for this image. While all of the different texture measures provided a degree of improvement (from 4 to 13% overall), the multiscale approach achieved a higher degree of classification accuracy regardless of which statistical procedure was used. When compared with single band texture measures, the level of overall improvement varied between 4 and 8%. The results indicate that this multiscale approach is an improvement over the current single band approach to analysing image texture.
Multi-spectral (ms) airborne lidar data are enriched relative to traditional lidar due to the multiple channels of intensity digital numbers (DNs), which offer the potential for active Spectral Vegetation Indices (SVIs), enhanced classification, and change monitoring. However, in case of SVIs, indices should be calculated from spectral reflectance values derived from intensity DNs after calibration. In this paper, radiometric calibration of multi-spectral airborne lidar data is presented. A novel low-cost diffuse reflectance coating was adopted for creating radiometric targets. Comparability of spectral reflectance values derived from ms lidar data for coniferous stand (2.5% for 532 nm, 17.6% for 1064 nm, and 8.4% for 1550 nm) to available spectral libraries is shown. Active vertical profiles of SVIs were constructed and compared to modeled results available in the literature. The potential for a new landscape-level active 3D SVI voxel approach is demonstrated. Results of a field experiment with complex radiometric targets for estimating losses in detected lidar signals are described. Finally, an approach for estimating spectral reflectance values from lidar split returns is analyzed and the results show similarity of estimated values of spectral reflectance derived from split returns to spectral reflectance values obtained from single returns (p > 0.05 for paired test).
Vicarious calibration is the determination of an on-orbit sensor’s radiometric response using measurements over test sites such as Railroad Valley (RRV), Nevada. It has the highest accuracy when a remote sensor’s view angle is aligned with that of the surface measurements, namely at a nadir view. For view angles greater than 10°, the dominant error is the uncertainty in the off-nadir correction factor. The factor is largest in the back-scatter principal plane and can reach 20%. The Orbiting-Carbon Observatory has access to a number of datasets to determine this deviation. These include measurements from field instruments such as the Portable Apparatus for Rapid Acquisition of Bidirectional Observation of the Land and Atmosphere (PARABOLA), as well as satellite measurements from Multi-angle Imaging SpectroRadiometer (MISR) and MODerate resolution Imaging Spectroradiometer (MODIS). The correction factor derived from PARABOLA is consistent in time and space to within 2% for view angles as large as 30°. Field spectrometer data show that the correction term is spectrally invariant. For this reason, a time-invariant model of RRV surface reflectance, along with empirically derived coefficients, is sufficient to use in the calibration of off-nadir sensors, provided there has been no recent rainfall. With this off-nadir correction, calibrations can be expected to have uncertainties within 5%.
29 June 2018 in International Journal of Remote Sensing
The recent popularization of unmanned aerial vehicles (UAVs) for use in terrestrial remote-sensing science has brought a class of inexpensive and largely unmeasured set of sensors into the scientific domain. Remote-sensing science demands high-quality data for information production and requires that the radiometric and spectral characteristics of imaging systems are known. This study compared the radiometric and spectral characteristics of 10 imaging systems commonly used in UAV research. From very inexpensive board-level cameras, consumer-grade cameras and purpose built remote-sensing systems were tested. The results show that sensor non-linearity with respect to radiance is a major limitation in producing reliable results. Spectral results demonstrated a degree of similarity between sensors with broad overlapping spectral bands being the norm. Careful attention to radiometric correction and spectral characterization will enhance the quality of the data produced from these systems.
3 July 2018 in International Journal of Remote Sensing
The foundation of all quantitative remote sensing is based on the ability of sensors to convert energy into digital signals. This process requires an understanding of the radiometric and spectral behaviour of the instrument. This information is rarely available for the consumer-grade digital cameras commonly used in unmanned aerial vehicle (UAV) systems. This study measured the spectral and radiometric characteristics of consumer-grade digital cameras in laboratory-based experiments. The spectral characteristics showed broad overlapping spectral bands in the visible and near-infrared wavelengths with spectral band widths between 70 and 100 nm. The radiometric response functions were non-linear in nature. The nonlinearity resulted in the inability of reliable spectral reflectance calculations. When compared to the spectral reflectance values computed from an ASD FieldSpec-3, differences were as high as 42% from the true value with average deviations between 23% and 32%. When characterized, the spectral reflectance values compared more favourably to ASD-computed spectral reflectance.
1 April 2009 in Photogrammetric Engineering & Remote Sensing