When gridded meteorological data drive finite element (FE) models, the interfaces carrying product identity, coordinates, axis order, time, and units are rarely checked. We built an auditable workflow linking an archived ECMWF gridded wind product, DEM metadata, Unity sampling, node exports, and ANSYS 2025 R2 comparisons, treating each interface as a gate that can fail. Three gates failed. The archived GRIB holds 48 monthly averages by hour of day (stream = mnth), not a continuous 48-h event; the runtime decoded magnitude from a constantly zero channel; and although the inline WGS84-to-UTM formula matches PROJ to 2.41 × 10−5 m, the wider mapping never closed, with none of the 234 towers inside the hard-coded wind subset and two Texture3D axes transposed. We then repaired what we could. Re-cropping the source to the line corridor and declaring the axis and vertical contracts moved tower containment from 0/234 to 234/234 and reproduced the source field to 0.0103 m/s against a 0.0307 m/s quantization step. Repeating the A–D solves with everything else fixed raised group A load from 292.050 to 355.034 N, displacement by 20.9%, and stress by 19.7%. The source time gate still fails, so results remain representative slot computations, not event responses. A synthetic control passes all six gates.
Assessing whether existing lattice towers can survive extreme wind when they are located on ridgelines or at saddle points requires three questions to be answered simultaneously: how the local wind field is modified by the surrounding topography, how the structural geometry recorded in legacy computer-aided design (CAD) drawings can be recovered accurately, and which member fails first and by what mechanism. This paper couples a Physics-Informed Neural Network (PINN) wind solver, jointly constrained by mass and momentum conservation, with a graph-theory-based Drawing Exchange Format (DXF) parser and a closed-loop vulnerability screening module, so that all three questions are answered in a single automated pass. The PINN reconstructs the three-dimensional steady-state wind field over irregular topography in approximately 0.12 s, holding the root-mean-square (RMS) velocity divergence below 2.1 × 10−3 (more than two orders of magnitude lower than that of linear interpolation) while recovering the pressure-gradient-driven acceleration that mass-consistent variational solvers cannot represent. On the CAD side, k-dimensional tree (KD-Tree) spatial indexing combined with breadth-first search (BFS) connected-component analysis resolves the pseudo-disconnections, spurious intersections, and multi-level nested block references that are common in production DXF files, achieving 100% node-merging accuracy across fifteen tower drawings. A unified Vulnerability Index (VI) that combines strength, member stability, and plate buckling into a single scalar, updated through Sherman–Morrison rank-one perturbation at a millisecond cost, closes the diagnose–strengthen–verify loop without re-solving the full stiffness system. Applied to a 220 kV line struck by Super Typhoon Meranti, the pipeline identified seven at-risk members that code-based checking had missed, a result consistent with the recorded field damage, and completed the full assessment in 34.4 s, over three orders of magnitude faster than conventional practice.