Vinícius Borges Oliveira

Mr. Vinícius Borges Oliveira

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2025 in Journal of Dentistry
Verified
Journal Article
Closed access
MFMichael Willian Favoreto
Michael Willian Favoreto
MWMichel Wendlinger
Michel Wendlinger
LBLaryssa Mylenna Madruga Barbosa
Laryssa Mylenna Madruga Barbosa
GCGabriel David Cochinski
Gabriel David Cochinski
VOVinícius Borges Oliveira
Vinícius Borges Oliveira
ALAlessandro D Loguercio
Alessandro D Loguercio

15 February 2025 in Journal of Dentistry
Verified
Journal Article
Closed access
LBLaryssa Mylenna Madruga Barbosa
Laryssa Mylenna Madruga Barbosa
GCGabrielle Gomes Centenaro
Gabrielle Gomes Centenaro
DCDeisy Cristina Ferreira Cordeiro
Deisy Cristina Ferreira Cordeiro
VOVinícius Borges Oliveira
Vinícius Borges Oliveira
MFMichael Willian Favoreto
Michael Willian Favoreto
ALAlessandro D Loguercio
Alessandro D Loguercio

19 February 2026 in Odontology
Verified
Journal Article
Open access
VOVinícius Borges Oliveira
Vinícius Borges Oliveira
JGJuliana Anany Gonzales Guarneri
Juliana Anany Gonzales Guarneri
MMMilena Ferreira Machado
Milena Ferreira Machado
LCLucas Arrais Campos
Lucas Arrais Campos
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
To evaluate the effect of 15- and 30-psi air spray on in vitro pulp temperature (PT) during light-curing of buccal Class V restorations in lower incisors using preheated resin composites (RBCs). After ethical approval, a Class V cavity was prepared in a sound lower central incisor. A T-type thermocouple was inserted into the pulp chamber and connected to a temperature measurement system (Thermes WiFi, Physitemp). Simulated pulpal fluid flow was maintained at a rate of 0.001 mL/min. Real-time PT and working time were recorded during restoration with Viscalor Bulk-fill (VOCO) and Filtek One Bulk-fill (Solventum) preheated to 68 °C. Air spray (15 or 30 psi) was directed to the lingual surface, starting 3 s before and maintained throughout light-curing ( n = 9). Vickers hardness (VHN) was measured at the middle and inner surfaces near the top and bottom of each specimen. PT and VHN data were analyzed using nonparametric mixed ANOVA, and working time was analyzed using nonparametric two-way ANOVA, both followed by Bonferroni’s post hoc tests ( α = 0.05). Light-curing of preheated RBCs significantly increased PT (42.5 ± 1.3 °C; p < 0.001). Air spray at 15 and 30 psi reduced PT values (28.4 ± 1.3 °C and 26.8 ± 1.8 °C, respectively; p < 0.001) without affecting VHN values. Air spray during light-curing effectively minimized pulp temperature rise during restorative procedures using preheated RBCs on lower incisors.

20 July 2026 in Materials
Verified
Journal Article
Open access
PDF file
CMCristiane Maucoski
Cristiane Maucoski
JGJuliana Anany Gonzales Guarneri
Juliana Anany Gonzales Guarneri
MRMaria Tereza Hordones Ribeiro
Maria Tereza Hordones Ribeiro
MMMilena Ferreira Machado
Milena Ferreira Machado
VOVinícius Borges Oliveira
Vinícius Borges Oliveira
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
Directing a stream of air across the tooth when light curing resin-based composites (RBCs) may affect their degree of conversion (DC), maximum rate of polymerization (RPmax), and in vitro intrapulpal temperature. Methods: Filtek One Bulk Fill and VisCalor bulk were preheated according to the manufacturer’s instructions and used to fill a Class I cavity in a molar at 32 °C. A stream of air at either 15 or 30 psi was directed across the tooth from an air-water syringe positioned 1 cm from the buccal surface. The RBCs were light-cured for 20 s using the Bluephase N, and the DC and RPmax were determined from real-time FT-IR data. A T-type thermocouple positioned inside the pulp chamber recorded the temperature. DC and RPmax data were analyzed using one-way ANOVA, whereas temperature was analyzed using two-way ANOVA, followed by Tukey post hoc tests. Results: Directing a stream of air at the tooth produced no significant differences in the DC and RPmax. The temperature change (ΔT) decreased compared to when no air was delivered. No significant difference in ΔT was found between the two air pressures. Conclusions: Directing a stream of air across the tooth when the preheated RBC was inserted did not affect the polymerization kinetics. The air stream reduced the temperature rise inside the pulp chamber as the RBC was light-cured. Clinical Significance: Directing a stream of air across the tooth at either 15 psi or 30 psi during light curing is an easy method to reduce the temperature increase inside the pulp chamber without affecting the polymerization kinetics of the evaluated preheated RBCs in this in vitro model.

28 October 2026 in European Journal of Oral Sciences
Verified
Journal Article
Open access
CFCamila Falconí‐Páez
Camila Falconí‐Páez
BCByron Carpio-Salvatierra
Byron Carpio-Salvatierra
DMDiego Meléndez
Diego Meléndez
RSRafaely Cristiane Stadler
Rafaely Cristiane Stadler
VOVinícius Borges Oliveira
Vinícius Borges Oliveira
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
The objective of this study was to assess the 12‐month clinical performance of a nano‐encapsulated Quercetin‐containing universal adhesive applied in non‐carious cervical lesions (NCCL). Forty‐three participants were included in this split‐mouth randomized trial. Eighty‐six NCCL restorations were placed by two operators and randomly assigned to Prime&Bond Universal (PBU) or Prime&Bond Universal containing nano‐encapsulated Quercetin (PBUQ), both applied in self‐etch mode (n = 43). Resin composite was incrementally placed. Clinical evaluations were performed at baseline, 6, and 12 months using the World Dental Federation (FDI) and US Public Health Service (USPHS) criteria. Data were analyzed using Friedman repeated‐measures and Kaplan–Meier survival analyses. No significant differences were observed at any period between FDIand USPHS clinical criteria. Retention rates were 97.70% (95% CI: 87.9–99.5) for the PBU group and 100% (95% CI: 91.8–100) for the PBUQ group. One restoration failed due to loss of retention in the PBU group. Minor marginal staining was detected in six restorations (PBU = 3; PBUQ = 3), and minimal marginal adaptation discrepancies were observed in four restorations (PBU = 2; PBUQ = 2). In conclusion, modifications of universal adhesives with nano‐encapsulated Quercetin may be explored without compromising early clinical performance, supporting further development of bioactive adhesive systems and long‐term relevance.