Cristiane Maucoski

Dr. Cristiane Maucoski


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2026 in Materials
Verified
Journal Article
Open access
PDF file
RDRaphaël Decroos
Raphaël Decroos
CMCristiane Maucoski
Cristiane Maucoski
BMBrett MacNeil
Brett MacNeil
DDDarien DeWolf
Darien DeWolf
DLDaniel Labrie
Daniel Labrie
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
The polymerization shrinkage stress (SS), degree of conversion (DC), and Vickers hardness (HV) are properties that can affect the performance of resin-based composites (RBCs). This study tested four bulk-fill RBCs used in self-cured mode: Bulk EZ Plus (Zest Dental Solutions), Cention Forte (Ivoclar), Fill-Up! (Coltene), and Stela (SDI Limited), and two light-cured bulk-fill RBCs: Filtek One (Solventum) and SDR flow+ (Dentsply). The test specimens were 6 mm in diameter and 2 mm thick. Axial SS was measured in real time for 4000 s in the self-cured materials and for 1400 s after 10 s of light curing in the light-cured materials (n = 12 for self-cured RBCs; n = 11 for light-cured RBCs). To confirm that the RBCs were adequately polymerized, the DC was assessed using real-time ATR-FTIR spectroscopy, and the HV was measured on the top and bottom surfaces using a 300-gf load for 8 s (n = 5) after 24 h. The SS, DC, and HV differed significantly among the RBCs (p < 0.001). At 1400 s, Cention Forte developed the lowest stress (1.44 MPa), whereas Bulk EZ Plus and Fill-Up! produced the highest stress (3.77 MPa). The self-cured materials continued to develop measurable stress between 1400 s and 4000 s, while the light-cured RBCs had stabilized at 1400 s. Bulk EZ Plus and Stela produced the highest DC values, and Stela had the highest HV.

20 July 2026 in Materials
Verified
Journal Article
Open access
PDF file
CMCristiane Maucoski
Cristiane Maucoski
JGJuliana Anany Gonzales Guarneri
Juliana Anany Gonzales Guarneri
MRMaria Tereza Hordones Ribeiro
Maria Tereza Hordones Ribeiro
MMMilena Ferreira Machado
Milena Ferreira Machado
VOVinícius Borges Oliveira
Vinícius Borges Oliveira
CACESAR AUGUSTO GALVAO ARRAIS
CESAR AUGUSTO GALVAO ARRAIS
Directing a stream of air across the tooth when light curing resin-based composites (RBCs) may affect their degree of conversion (DC), maximum rate of polymerization (RPmax), and in vitro intrapulpal temperature. Methods: Filtek One Bulk Fill and VisCalor bulk were preheated according to the manufacturer’s instructions and used to fill a Class I cavity in a molar at 32 °C. A stream of air at either 15 or 30 psi was directed across the tooth from an air-water syringe positioned 1 cm from the buccal surface. The RBCs were light-cured for 20 s using the Bluephase N, and the DC and RPmax were determined from real-time FT-IR data. A T-type thermocouple positioned inside the pulp chamber recorded the temperature. DC and RPmax data were analyzed using one-way ANOVA, whereas temperature was analyzed using two-way ANOVA, followed by Tukey post hoc tests. Results: Directing a stream of air at the tooth produced no significant differences in the DC and RPmax. The temperature change (ΔT) decreased compared to when no air was delivered. No significant difference in ΔT was found between the two air pressures. Conclusions: Directing a stream of air across the tooth when the preheated RBC was inserted did not affect the polymerization kinetics. The air stream reduced the temperature rise inside the pulp chamber as the RBC was light-cured. Clinical Significance: Directing a stream of air across the tooth at either 15 psi or 30 psi during light curing is an easy method to reduce the temperature increase inside the pulp chamber without affecting the polymerization kinetics of the evaluated preheated RBCs in this in vitro model.