Anwar Shahzad Siddiqui

Prof. Anwar Shahzad Siddiqui


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
PPPrashant Prashant
Prashant Prashant
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui
MSMd Sarwar
Md Sarwar
AAAhmed Althobaiti
Ahmed Althobaiti
Sherif GhoneimSherif Ghoneim
Sherif Ghoneim
This article presents the selection of location and sizing of multiple distributed generators (DGs) for boosting performance of the radial distribution system in the case of constant power load flow and constant impedance load flow. The consideration of placing and sizing of DGs is to meet the load demand. This article tries to overcome the limitations of existing techniques for determining the appropriate location and size of DGs. The selection of DG location is decided in terms of real power losses, accuracy, and sensitivity. The size of DG is measured in terms of real and reactive power. Both positioning and sizing of DG are analyzed with the genetic algorithm and the heuristic probability distribution method. The results are compared with other existing methods such as ant-lion optimization algorithm, coyote optimizer, modified sine-cosine algorithm, and particle swarm optimization. Further, the power quality improvement of the network is assessed by positioning D-STATCOM, and its location is decided on the basis of the nearby bus having poor voltage profile and high total harmonic distortion (THD). The switching and controlling of D-STATCOM are assessed with fuzzy logic controller (FLC) for improving the performance parameters such as voltage profile and THD at that particular bus. The proposed analytical approach for the system is tested on the IEEE 33 bus system. It is observed that the performance of the system with the genetic algorithm gives a better solution in comparison to heuristic PDF and other existing methods for determining the optimal location and size of DG. The introduction of D-STATCOM into the system with FLC shows better performance in terms of improved voltage profile and THD in comparison to existing techniques.

9 March 2022 in Protection and Control of Modern Power Systems
Verified
Journal Article
Open access
PDF file
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui
PPPrashant Prashant
Prashant Prashant
In existing power system networks, the positioning and sizing of multi-DG is critical at the optimum locations for effective energy management. Initially optimal power flow is assessed using the NR method (without DG) in which performance parameters such as real power loss, accuracy, selectivity and MSE are obtained, but in an undesirable manner. To meet load demand; multi-DGs are placed and their optimal locations are assessed by the proposed heuristic probability distribution methodology and an ANN because existing techniques provides poor performance parameters for selecting the location and sizing of DGs. The optimal positions of multi-DGs are estimated in terms of performance parameters including real power loss of transmission network, accuracy, selectivity and MSE, while the performance parameters obtained with the ANN are better than the heuristic pdf. Then, the sizing of multi-DGs is evaluated in relation to active and reactive power. It is found that that sizes of multi-DGs are smaller with ANN than with heuristic pdf. It is preferable to connect the buses having lowest real power losses with the smallest multi-DGs. The performance analysis is tested in the standard IEEE 9- bus and IEEE 57- bus systems on Simulink. To improve the distortion level in real and reactive power, multi-FACTS namely TCSC, TSC and STATCOM are used. The switching of TCSC and TSC is done by SPWM while STATCOM switching is controlled with ANFIS. The locations of multi-FACTS devices are chosen for buses having larger distortion and the sizing of multi-FACTS devices is also optimally decided. The application of multi-FACTS devices helps to improve power quality and fulfill load demand with minimal size in order to make the system economical.

18 April 2014 in International Journal of System Assurance Engineering and Management
Verified
Journal Article
Closed access
PDF file
MKMohd Tauseef Khan
Mohd Tauseef Khan
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui

13 January 2015 in International Journal of System Assurance Engineering and Management
Verified
Journal Article
Closed access
PDF file
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui
MKMohd Tauseef Khan
Mohd Tauseef Khan
FIFahad Iqbal
Fahad Iqbal

13 August 2021 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
PPPrashant Prashant
Prashant Prashant
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui
ASABHINAV SAXENA
ABHINAV SAXENA
This article presents intelligent controlling on locational marginal pricing (LMP) of deregulated system for congestion management. Transmission line congestion is a critical concern, and its governance raises a technological obstacle when deregulating the electricity grid. Congestion throughout the unregulated energy market occurs where transmitting capacity is not adequate to reach all the demand transmission constraints across a line. The congestion management is decided by using the LMP difference between two buses. The existing methods have higher LMP cost due to which controlling of LMP is assessed by using a hybrid approach and genetic algorithm (GAs). The LMP difference obtained with GAs is lesser than hybrid approach which makes system economical. After the selection of uniform and high demanded congested zone, a distributed generator (DG) is used to fulfill the demand. The DG is represented by solar PV array and connected to bus through converters. The switching of the converter is assessed by a fuzzy logic controller (FLC) and vector control. The implementation of FLC improves the THD of real and reactive power generated by DG in a better way in comparison to vector control. The performance analysis is tested on standard IEEE 9-bus system, standard IEEE 14-bus system, and standard IEEE 57-bus system on Simulink.

15 June 2014 in International Journal of System Assurance Engineering and Management
Verified
Journal Article
Closed access
PDF file
RJRashmi Jain
Rashmi Jain
ASAnwar Shahzad Siddiqui
Anwar Shahzad Siddiqui
MJMajid Jamil
Majid Jamil
CGC. P. Gupta
C. P. Gupta
PRPreeti
Preeti