Dayang Wang

Dr. Dayang Wang


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 November 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
DWDayang Wang
Dayang Wang
NJNingde Jin
Ningde Jin
Lusheng ZhaiLusheng Zhai
Lusheng Zhai
YRYingyu Ren
Yingyu Ren
A novel coaxial three-electrode distributed conductance sensor (CTDCS) is proposed to achieve salinity and oil content independent measurement of liquid film thickness in multiphase slug flow. Conductance sensor obtains liquid film thickness by measuring the conductance between electrodes. However, the conductance depends on the liquid film thickness and the liquid conductivity. For gas-water and oil-gas-water flows in industrial process, the variations of salinity and oil content of liquid phase change the liquid conductivity. This will seriously affects the measurement of liquid film thickness using conventional two-electrode sensor. Owing to its novel three-electrode configuration, the proposed CTDCS can overcome the problem mentioned above. The optimal geometry of CTDCS are determined by exhaustive search using finite element method, and the electronic circuit suitable for the condition of conductivity variation is investigated. The ratio of two-channel outputs which is independent of conductivity is acquired and its relationship with the liquid film thickness is established. The advantages of the CTDCS are that it can on-line compensate conductivity variations, and acquire the circumferential distribution of liquid film thicknesses. Hence, salinity and oil content independent measurement of liquid film thickness is realized for the first time.

17 June 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YDYuan-Rong Deng
Yuan-Rong Deng
NJNingde Jin
Ningde Jin
QYQiu-Yi Yang
Qiu-Yi Yang
DWDayang Wang
Dayang Wang
In the process of production logging to evaluate fluid flow inside pipe, logging tools that force all flow to pass through a small measuring pipe are commonly utilized for measuring mixture density. For these logging tools, studying the fluid flow phenomenon inside the small diameter pipe and improving the prediction accuracy of pressure drop are beneficial to accurately measure mixture density. In this paper, a pressure drop prediction system is designed based on a combination of an eight-electrode rotating electric field conductance sensor (REFCS), plug-in cross-correlation conductance sensor, and differential pressure sensor. This combination overcomes the limitation of the existing pressure drop prediction model that the inlet flow velocity needs to be known. An experiment is conducted in a flow loop facility with 20 mm inner diameter small pipe. The responses of the combination sensors are collected. The REFCS is used to identify flow pattern and measure water holdup. During which five flow patterns are identified by recurrence plot method, i.e., slug flow, bubble flow, churn flow, bubble-slug transitional flow, and slug-churn transitional flow. The mixture velocity of two-phase flow is determined by the plug-in conductance sensor. The differential pressure sensor provides a differential pressure fluctuation signal. Five models of prediction of pressure drop are evaluated. The mixture friction factor of gas-water two-phase flow is obtained by a fitting method based on the measured parameters and flow pattern identification using the optimal model. Then, the pressure drop can be predicted according to the measurement results of a conductance sensor and fitting relationship. The results of pressure drop prediction show that the model proposed by Ansari et al. presents a higher accuracy compared with the other four differential pressure models with the absolute average percentage deviation (AAPD) of less than 2.632%. Moreover, the accuracy of pressure drop prediction of the Zhang et al. model is improved by using the mixture friction factor.

26 August 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
QYQiuyi Yang
Qiuyi Yang
NJNingde Jin
Ningde Jin
YDYuanrong Deng
Yuanrong Deng
DWDayang Wang
Dayang Wang
In order to reduce the measurement error caused by non-uniform distribution of dispersed phase, distributed differential pressure sensors are used to measure the pressure drop of gas-liquid flows in small diameter pipe. Water holdup in vertical upward pipe is predicted by the distributed differential pressure sensors, based on the correlations of mixture friction coefficient ftp under different flow patterns. The water holdup measured by the rotating electric field conductivity sensor is used as the reference value based on the improved Maxwell equations. The dynamic experiments prove that the water holdup prediction accuracy of Ansari model is higher than that of Zhang model, and it can achieve a satisfactory prediction result for water holdup of gas-liquid two-phase flow in small diameter pipe. The average absolute deviation (AAD) of the predicted water holdup relative to the reference water holdup is 0.026, and the average absolute percentage deviation (AAPD) is 5.52%.

18 June 2019 in Zeitschrift für Naturforschung A
Verified
Journal Article
Closed access
PDF file
YLYudong Liu
Yudong Liu
DWDayang Wang
Dayang Wang
YRYingyu Ren
Yingyu Ren
NJNingde Jin
Ningde Jin
Due to the complex flow structure and non-uniform phase distribution in the vertical upward gas-liquid two-phase flow, an eight-electrode rotating electric field conductance sensor is used to obtain multi-channel conductance signals. The flow patterns of the vertical upward gas-liquid two-phase flow are classified according to the images obtained from a high-speed camera. Then, we employ the multivariate weighted multi-scale permutation entropy (MWMPE) to detect the instability of flow pattern transition in the gas-liquid two-phase flow. Afterwards, we compare the results of the MWMPE with those of the single-channel weighted multi-scale permutation entropy (SCWMPE) and multivariate multi-scale sample entropy (MMSE). The comparison results indicate that, compared with the SCWMPE and MMSE, the MWMPE has superior performance in terms of the high-resolution presentation of flow instability in the gas-liquid two-phase flow. Finally, we extract the mean value of the MWMPE in whole scales and the entropy rate of the MWMPE in the small scales. The results indicate that the normalized mean value and normalized entropy rate of MWMPE are very sensitive to the transitions of flow patterns, thus allowing the detection of the instability of flow pattern transition.

17 March 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
DWDayang Wang
Dayang Wang
NJNingde Jin
Ningde Jin
Lusheng ZhaiLusheng Zhai
Lusheng Zhai
YRYingyu Ren
Yingyu Ren
In this study, a new method for gas holdup measurement in water continuous oil-gas-water multiphase flow based on conductance sensors is proposed. This method includes the use of the combined conductance sensors and the establishment of gas holdup model. A cross-sectional type conductance sensor is applied to acquire the conductivity of oil-gas-water mixture. For the purpose to derive gas holdup from the mixture conductivity, a novel liquid conductivity sensor which has shallow detection depth is proposed and it is flush-mounted on the inner wall of pipe to detect the liquid conductivity. The performances of the cross-sectional type conductance sensor combined with the liquid conductivity sensor are evaluated by experiments. And the results indicate that the liquid conductivity sensor can online detect the liquid conductivity in the multiphase mixture effectively. Based on the measured conductivity of multiphase mixture and the conductivity of liquid, the normalized conductivity which is related to the gas holdup is defined. The gas holdup model based on flow structures is investigated and established, and finally the measurement of gas holdup independently of salinity in oil-gas-water multiphase flow based on the conductance method is achieved for the first time.

15 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
DWDayang Wang
Dayang Wang
NJNingde Jin
Ningde Jin
Lusheng ZhaiLusheng Zhai
Lusheng Zhai
YRYingyu Ren
Yingyu Ren
Flow measurement in gas-liquid two-phase flow is always a challenging work, because of the non-uniform phase distribution, severe slippage effect between phases, and different flow structures. Furthermore, the variation of salinity changes the water conductivity, which brings more difficulties to multiphase flow measurement. In this study, a methodology for flow measurement using the conductance method in gas-liquid two-phase flow with salinity change is proposed. The methodology includes the suitable conductivity detection method, the strategy of using combined sensors, and the measurement models of flow parameters. A suitable conductivity detection method that can guarantee that the sensor output is linearly proportional to the conductivity is proposed. This conductivity detection method can ensure that the sensors have a high and constant resolution in the conductivity variation caused by water holdup under the conditions of water conductivity change. Afterward, a combined sensor system consisting of a water holdup sensor, velocity sensor, and water conductivity sensor is designed and experimentally evaluated in gas-water two-phase flow in a 20 mm inner diameter pipe. Considering the non-uniform phase distribution, severe slippage effect between phases, different flow structures, and the variation of salinity, a new water holdup measurement model and flow velocity measurement models are established to achieve salinity independent water holdup measurement and flow velocity measurement for the first time.