Considering the widespread use of surgical robots in recent years, computer-assisted surgery is becoming significantly popular. Because the automation of surgical tasks without human intervention remains complex owing to individual patient differences, a human cooperative control is proposed in this study. A system in which an operator manipulates one surgical instrument to insert a suture needle was developed, along with another surgical instrument that automatically pulls out the needle from the operated instrument. In the proposed method, YOLOv3 and a standard convolutional neural network (CNN) are used to estimate the penetration and pull state of the needle. An image-based state estimator classifies the state regardless of the stiffness of the object to which the suture needle is inserted. Furthermore, after the pull state is detected, despite a failure of the needle pulling, the position can be corrected and the automated surgical instrument can approach the needle again. Experiments on human cooperative control demonstrated the effectiveness of state estimation using the proposed method. In addition, the failure of grasping observed in a previous study caused by the needle angle error was reduced.
17 November 2023 in IEEE Robotics and Automation Letters
Soft robotics is a swiftly evolving field. Pneumatic actuators are suitable for driving soft robots because of their superior performance. However, their control is challenging due to the hysteresis characteristics. In response to this challenge, we propose an adaptive control method to compensate for the hysteresis of soft actuators. Employing a novel dual pneumatic artificial muscle (PAM) bending actuator, the innovative control approach abates hysteresis effects by dynamically modulating gains within a traditional PID controller corresponding to the predicted variation of the reference trajectory. Through experimental evaluation, we found that the proposed control method outperforms its conventional counterparts regarding tracking accuracy and response speed. Our work reveals a new direction for advancing model-free control in soft actuators.
Power assistive devices have been developed in recent years. To detect the wearer’s motion, conventional devices require users to wear sensors. However, wearing many sensors increases the wearing time, and usability of the device will become worse. We developed a soft gait assistive suit actuated by pneumatic artificial rubber muscles (PARMs) and proposed its control method. The proposed suit is easy to wear because the attachment unit does not have any electrical sensors that need to be attached to the trainee’s body. A target application is forward walking exercise on a treadmill. The control unit detects the pre-swing phase in the gait cycle using the pressure information in the calf back PARMs. After the detection, the suit assists the trainee’s leg motion. The assist force is generated by the controlled PARM pressure, and the pressure input time is changed appropriately considering the gait cycle time. We conducted walking experiments; (1) verifies the proposed control method works correctly, and (2) verifies whether the gait assistive suit is effective for decreasing muscular activity. Finally, we confirmed that the accurate phase detection can be achieved by using the proposed control method, and the suit can reduce muscular activity of the trainee’s leg.
A cylindrical soft actuator is suitable for applications in which pneumatic or hydraulic cylinders are conventionally used. In this report, we discuss the force output model of a spring-reinforced-type cylindrical soft actuator. This type of actuator outputs a larger force than the air pressure multiplied by the pressure-receiving area. We construct a quasi-static model to explore the reason for this phenomenon, based on the strength of materials. A thick-walled cylinder model with three boundary conditions was defined and analyzed. The model indicates that the rubber cylinder itself transmits pneumatic pressure and contributes to the output force. We also modeled the relationship between the pressure and the elongation of the soft actuator. Experiments were conducted to evaluate the proposed models.
26 December 2024 in IEEE Robotics and Automation Letters
The nonlinearities of soft robots bring control challenges like hysteresis but also provide them with computational capacities. This letter introduces a fuzzy pneumatic physical reservoir computing (FPRC) model for feedforward hysteresis compensation in motion tracking control of soft actuators. Our method utilizes a pneumatic bending actuator as a physical reservoir with nonlinear computing capacities to control another pneumatic bending actuator. The FPRC model employs a Takagi-Sugeno (T-S) fuzzy logic to process outputs from the physical reservoir. The proposed FPRC model shows equivalent training performance to an Echo State Network (ESN) model, whereas it exhibits better test accuracies with significantly reduced execution time. Experiments validate the FPRC model's effectiveness in controlling the bending motion of a pneumatic soft actuator with open-loop and closed-loop control system setups. The proposed FPRC model's robustness against environmental disturbances has also been experimentally verified. To the authors' knowledge, this is the first implementation of a physical system in the feedforward hysteresis compensation model for controlling soft actuators. This study is expected to advance physical reservoir computing in nonlinear control applications and extend the feedforward hysteresis compensation methods for controlling soft actuators.
1 January 2022 in Sensors and Actuators A: Physical