Tao Zhang

Dr. Tao Zhang


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Hang LuoHang Luo
Hang Luo
HSHongbin Advances in Wearable Tactile Sensors Based on Electrospun Nanofiber Su
Hongbin Advances in Wearable Tactile Sensors Based on Electrospun Nanofiber Su
QTQiwen Tang
Qiwen Tang
FNFazal Ul Nisa
Fazal Ul Nisa
LHLiang HE
Liang HE
Zhen LiuZhen Liu
Zhen Liu
As typical examples of rotational rate sensors, microelectromechanical system (MEMS) gyroscopes have been widely applied as inertial devices in various fields, including national defense, aerospace, healthcare, etc. This review systematically summarizes research advancements in MEMS gyroscope structural forms and processing technologies, which are evaluated through performance indices. The review encompasses several areas. First, it outlines the modelling principles and processes of gyroscopes on the basis of the Coriolis force and resonance, establishing a theoretical foundation for MEMS gyroscope development. Second, it introduces and analyzes the latest research advances in MEMS gyroscope structures and corresponding processing technologies. On the basis of published research advances, this review categorically discusses multidisciplinary technology properties, statistical results, the existence of errors, and compensation methods. Additionally, it identifies challenges in MEMS gyroscope technologies through classification analysis.

30 September 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ZZZhigang Zhang
Zhigang Zhang
ATAimin Tang
Aimin Tang
TZTao Zhang
Tao Zhang
Pumps are one of the core components of drilling equipment, and their fault diagnosis is of great significance. The data-driven approach has made remarkable achievements in the field of pump fault diagnosis; however, most of them are easily affected by complex background conditions and usually suffer from data scarcity problems in real-industrial scenarios, which limit their application in practical engineering. To overcome the above shortcoming, a novel framework for a model named Hyperparameter Optimization Multiple-Signal Fusion Transfer Convolution Neural Network is proposed in this paper. A convolutional neural network model based on transfer learning is built to promote well-learned knowledge transfer over different background conditions, improve robustness, and generalize the model to cross-domain diagnosis tasks. The multi-signal fusion strategy is involved in capturing system state information for establishing the mapping relationship between the raw signal and fault pattern by integrating the multi-physical signal with the weight allocation protocol. The hyperparameter optimization method is explored in conjunction with the transfer-based model by integrating Grid Search with the Gradient Descent algorithm for further improvement of diagnosis performance. Results show that the proposed model can effectively realize the fault diagnosis of pumps under different background conditions, achieving 95% accuracy.

1 December 2002 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
TZTao Zhang
Tao Zhang
ZZZhao-Fei Zhou
Zhao-Fei Zhou
WLWenjie Li
Wenjie Li
WHWei Huang
Wei Huang
A study of integration for different sensing functions is described. Three different noncontact measuring functions, including a micrometer, a roughness meter, and a profilometer, are integrated into one new sensor. In this sensor, one common laser source, optical system, and photodetector are shared. Based on the theory of laser scattering and interferometry, this sensor can be used to measure the surface roughness and microprofile with the measurement range of Ra=0.001 to 3 μm. Based on the theory of triangulation this sensor can be used to measure the microdisplacement with a measurement range of 0.5 to 300 μm. The accuracies of this sensor are similar to each existing single sensor for the same function. A typical application of this sensor is to complete the measurements of the diameter, surface quality, and form error of a cylinder or cannon in operation. This integrated sensor is applicable to design a virtual instrument with multiple functions. © 2002 Society of Photo-Optical Instrumentation Engineers.

4 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ZLZewei Liu
Zewei Liu
YZYuanchen Zhu
Yuanchen Zhu
ZZZhigang Zhang
Zhigang Zhang
TZTao Zhang
Tao Zhang
High-pressure quintuplex pumps are key components in oil and gas drilling systems, but their fault diagnosis remains challenging due to severe inter-cylinder vibration crosstalk, operating-condition variability, and limited labeled samples. To address these issues, this paper proposes an integrated vibration-based diagnostic framework, termed VICA-DA-ViT. First, a VMD–FastICA-based blind source separation strategy is used to suppress inter-cylinder crosstalk and extract more discriminative vibration components from mixed signals. Then, angular-domain resampling and normalization are applied to reduce speed-induced non-stationarity and improve cycle consistency. The processed one-dimensional signals are further converted into two-dimensional GAF–RP representations, where GAF captures global temporal correlations and RP provides complementary recurrence information. Finally, a ViT-based domain-adaptive diagnostic framework is constructed for unsupervised cross-condition diagnosis by integrating domain-adversarial pretraining, weighted bidirectional sample pairing, and Gaussian-mixture-based confidence filtering around a standard Vision Transformer backbone. Rather than modifying the internal architecture of ViT, the proposed framework improves cross-condition generalization by combining signal decoupling, angular-domain alignment, and domain-adaptation strategies for high-pressure quintuplex pump fault diagnosis. Experiments on a quintuplex pump dataset under multiple operating conditions show that the proposed framework achieves an average cross-condition accuracy of 87.42%, outperforming CD-Trans by 11.94%. These results demonstrate that VICA-DA-ViT can effectively improve the robustness of small-sample cross-condition fault diagnosis for high-pressure quintuplex pumps.