Shamim Ahmed Deowan

Dr. Shamim Ahmed Deowan

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2024 in Energy Reports
Verified
Journal Article
Open access
ZMZiaul Hasan Majumder
Ziaul Hasan Majumder
MSMosa. Tania Alim Shampa
Mosa. Tania Alim Shampa
AIAriful Islam
Ariful Islam
SDShamim Ahmed Deowan
Shamim Ahmed Deowan
FHFarhana Hafiz
Farhana Hafiz

1 August 2023 in IEEE Access
Verified
Journal Article
Open access
SAShifat E. Arman
Shifat E. Arman
SRSayed Saminur Rahman
Sayed Saminur Rahman
NINiloy Irtisam
Niloy Irtisam
SDShamim Ahmed Deowan
Shamim Ahmed Deowan
MIMd. Ariful Islam
Md. Ariful Islam
MHMehedi Hasan
Mehedi Hasan
Intracranial hemorrhage is a medical condition that involves bleeding within the skull or brain tissue. It has mainly five subtypes - epidural hemorrhage, subdural hemorrhage, subarachnoid hemorrhage, intraparenchymal hemorrhage, and intraventricular hemorrhage. In order to ensure a successful outcome for a patient, a timely and accurate detection of intracranial hemorrhage is crucial. Despite this, there is a shortage of radiologists, especially in rural areas, which can lead to a delay in diagnosis. In this work, we proposed an automatic way of diagnosing intracranial hemorrhage from a CT scan. We have optimized the DenseNet architecture using Bayesian Optimization (BO) to diagnose intracranial hemorrhage effectively. Using BO, we identified the optimal learning rate, optimizer, and number of dense nodes for the DenseNet architecture. Our proposed model can analyse whether hemorrhage is present in a CT scan and, if it is present, what its subtype is. The optimized DenseNet model was able to achieve a very high accuracy of 98.02% on the test set. By ensuring accurate and reliable diagnoses, our method will assist doctors in making better-informed decisions and providing better care for their patients.

20 April 2021 in SN Computer Science
Verified
Journal Article
Closed access
PDF file
RNRagib Amin Nihal
Ragib Amin Nihal
NBNawara Mahmood Broti
Nawara Mahmood Broti
SDShamim Ahmed Deowan
Shamim Ahmed Deowan
SRSejuti rahman
Sejuti rahman

24 June 2023 in Journal of Intelligent & Robotic Systems
Verified
Journal Article
Closed access
PDF file
MIMd. Ariful Islam
Md. Ariful Islam
MHMd Mehedi Hasan
Md Mehedi Hasan
SDShamim Ahmed Deowan
Shamim Ahmed Deowan

30 December 2021 in SN Computer Science
Verified
Journal Article
Closed access
PDF file
SAShifat E. Arman
Shifat E. Arman
SRSejuti rahman
Sejuti rahman
SDShamim Ahmed Deowan
Shamim Ahmed Deowan

27 March 2019 in Applied Water Science
Verified
Journal Article
Open access
PDF file
SDShamim Ahmed Deowan
Shamim Ahmed Deowan
WKWladimir Korejba
Wladimir Korejba
JHJan Hoinkis
Jan Hoinkis
Alberto FIGOLIAlberto FIGOLI
Alberto FIGOLI
Enrico DrioliEnrico Drioli
Enrico Drioli
LJLafifa Jamal
Lafifa Jamal
The objective of this paper is to deal with the design of a pilot-scale submerged membrane bioreactor (MBR) and a short-term functionality test to be performed with textile wastewater. The design calculations were done based on the design parameters analysed from local textile wastewater and typical values of activated sludge kinetic coefficients. Other process parameters like bioreactor volume (tank size), hydraulic residence time (HRT), biomass loading (F/M ratio), oxygen demand, etc., were calculated depending on the real textile wastewater characteristics. Taking the design basis into consideration, a pilot-scale MBR was constructed equipped with LabVIEW programme- and sensors-controlled computer system. Based on the theoretical calculations, the hydraulic volume of the MBR reactor was around 56.6 L with flat sheet membranes (3 sheets, with 25 cm × 25 cm dimensions of each sheet) with HRT of 16.9 h. Finally, performance tests for 6 weeks were carried out in a local (Darmstadt, Germany) laundry textile wastewater to test the functionality of MBR pilot plant. Under the operating conditions of 250 mbar suction pressure and 12 g/L of MLSS, the COD removal efficiency was around 90% for 800–3500 mg/L inlet COD fed to the membrane bioreactor.