Georgy Mihov

Dr. Georgy Mihov


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2005 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
CLChavdar Levkov
Chavdar Levkov
GMGeorgy Mihov
Georgy Mihov
RIRatcho Ivanov
Ratcho Ivanov
IDIvan Daskalov
Ivan Daskalov
ICIvaylo Christov
Ivaylo Christov
IDIvan Dotsinsky
Ivan Dotsinsky
Background: Modern biomedical amplifiers have a very high common mode rejection ratio. Nevertheless, recordings are often contaminated by residual power-line interference. Traditional analogue and digital filters are known to suppress ECG components near to the power-line frequency. Different types of digital notch filters are widely used despite their inherent contradiction: tolerable signal distortion needs a narrow frequency band, which leads to ineffective filtering in cases of larger frequency deviation of the interference. Adaptive filtering introduces unacceptable transient response time, especially after steep and large QRS complexes. Other available techniques such as Fourier transform do not work in real time. The subtraction procedure is found to cope better with this problem. Method: The subtraction procedure was developed some two decades ago, and almost totally eliminates power-line interference from the ECG signal. This procedure does not affect the signal frequency components around the interfering frequency. Digital filtering is applied on linear segments of the signal to remove the interference components. These interference components are stored and further subtracted from the signal wherever non-linear segments are encountered. Results: Modifications of the subtraction procedure have been used in thousands of ECG instruments and computer-aided systems. Other work has extended this procedure to almost all possible cases of sampling rate and interference frequency variation. Improved structure of the on-line procedure has worked successfully regardless of the multiplicity between the sampling rate and the interference frequency. Such flexibility is due to the use of specific filter modules. Conclusion: The subtraction procedure has largely proved advantageous over other methods for power-line interference cancellation in ECG signals.

31 October 2008 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
GMGeorgy Mihov
Georgy Mihov
IDIvan Dotsinsky
Ivan Dotsinsky

1 January 2005 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
GMGeorgy Mihov
Georgy Mihov
IDIv Dotsinsky
Iv Dotsinsky
TGTs Georgieva
Ts Georgieva
This paper presents an improvement of the subtraction procedure for interference cancellation in ECG. In contrast to the well-known hardware and software filters, the procedure does not affect the signal frequency components around the rated powerline frequency. Originally, the procedure was developed for multiplicity between the sampling rate and the interference frequency. We analysed and improved the procedure structure in cases of non-multiple sampling, introducing a set of specially designed filters. Thus the implementation of the subtraction procedure is extended to almost all possible cases of sampling rate and interference frequency variation. The procedure has been adapted for online implementation. The research was initially carried out in a MATLAB environment. Further, programmes have been written in C( + +) language for digital signal processors and personal computers. The results obtained with real ECG signals show high efficiency of the interference cancellation.

1 January 2008 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
IDIvan A Dotsinsky
Ivan A Dotsinsky
GMGeorgy Mihov
Georgy Mihov
Electrocardiogram recordings are very often contaminated by high-frequency noise usually power-line interference and EMG disturbances (tremor). Specific method for interference cancellation without affecting the proper ECG components, called subtraction procedure, was developed some two decades ago. Filtering out the tremor remains a priori partially successful since it has a relatively wide spectrum, which overlaps the useful ECG frequency band. The proposed method for tremor suppression implements the following three procedures. Contaminated ECG signals are subjected to moving averaging (comb filter with linear phase characteristic) with first zero set at 50 Hz to suppress tremor and PL interference simultaneously. The reduced peaks of QRS complexes and other relatively high and steep ECG waves are then restored by an introduced by us procedure called linearly-angular, so that the useful high frequency components are preserved in the range specified by the embedded in the ECG instrument filter, usually up to 125 Hz. Finally, a Savitzky-Golay smoothing filter is applied for supplementary tremor suppression outside the QRS complexes. The results obtained show a low level of the residual EMG disturbances together with negligible distortion of the wave shapes regardless of rhythm and morphology changes.

15 July 2026 in Batteries
Verified
Journal Article
Open access
PDF file
SRStefan Milkov Rizanov
Stefan Milkov Rizanov
ASAnna Stoynova
Anna Stoynova
GMGeorgy Mihov
Georgy Mihov
Reliable state of health (SOH) and remaining useful life (RUL) estimation is essential for lithium-ion battery diagnostics, prognosis, and management across cell, module, and pack levels. Yet the reported performance metrics often remain tied to controlled cell datasets, with batteries degrading due to chemistry shifts, protocol variation, temperature changes, inconsistent and insufficient measurements, and pack-level heterogeneity. This critical review investigates what evidence is required before an SOH/RUL estimator can be considered trustworthy, transferable, and suitable for battery management system deployment. Based on a de-duplicated classified set of 176 scientific works and a supplementary evidence audit workbook, this review synthesizes model-based, machine learning, deep learning, transfer learning, physics-informed, impedance-based, thermographic, relaxation-based, and digital twin approaches through observability, robustness, uncertainty calibration, transferability, and deployment feasibility. A compact mathematical framework formalizes the health inference, domain shift, cross-fidelity degradation, calibrated uncertainty, and BMS-facing validation criteria. The analysis argues that deployment-ready battery health intelligence should be evaluated as an evidence system rather than as a point prediction task. The proposed multi-fidelity validation framework links synthetic cells, controlled aging, module (pack) testing, fleet shadow operation, and closed-loop safety-governed deployment using acceptance criteria, based on worst-domain error, calibration data, warning risk, and computational feasibility.

5 January 2026 in Engineering Sciences
Verified
Journal Article
Closed access
GMGeorgy Mihov
Georgy Mihov
DBDimitar Badarov
Dimitar Badarov