Andreas Mueller

Prof. Dr. Andreas Mueller

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2013 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
PDF file
CRClaudio Rosso
Claudio Rosso
PVPatrick Vavken
Patrick Vavken
CPCaroline Polzer
Caroline Polzer
Daniel BucklandDaniel Buckland
Daniel Buckland
USUeli Studler
Ueli Studler
VVVictor Valderrabano
Victor Valderrabano

21 February 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FEFranziska Eckers
Franziska Eckers
SLStefan Loske
Stefan Loske
EEEugene Ek
Eugene Ek
AMAndreas Mueller
Andreas Mueller
Rotator cuff (RC) tears are among the most common musculoskeletal disorders and can be associated with pain, weakness, and shoulder dysfunction. In recent years, there have been significant advances with regard to the understanding of rotator cuff disease and its management. With technological improvements and advanced diagnostic modalities, there has been much progress as to improved understanding of the pathology. Similarly, with advanced implant designs and instrumentation, operative techniques have evolved. Furthermore, refinements in postoperative rehabilitation protocols have improved patient outcomes. In this scoping review, we aim to provide an overview of the current knowledge on the treatment of rotator cuff disorders and to highlight recent advances in its management.

8 September 2014 in The American Journal of Sports Medicine
Verified
Journal Article
Closed access
AMAndreas Mueller
Andreas Mueller
CRClaudio Rosso
Claudio Rosso
VEVahid Entezari
Vahid Entezari
BMBrett McKenzie
Brett McKenzie
AHAndrew Hasebroock
Andrew Hasebroock
JDJoseph P. DeAngelis
Joseph P. DeAngelis
Background: Supraspinatus tears are common in pitchers. However, the effect of these tears on glenohumeral (GH) mechanics is incompletely understood. Purpose/Hypothesis: To describe the effect of supraspinatus tears and repairs on GH kinematics during an abbreviated throwing motion using the intact shoulder girdle. The hypothesis was that supraspinatus tears would lead to an increase of GH translation in the coronal plane and supraspinatus repairs would restore GH kinematics. Study Design: Controlled laboratory study. Methods: Six shoulders from 3 fresh-frozen cadavers were tested in a novel 7 degrees of freedom robotic testing system. Torsos were mounted and the wrist was pinned to an actuator mounted on an upper frame. After the deltoid was removed, the shoulders were studied during an abbreviated throwing motion (ATM) from maximum external rotation to the midcoronal plane to establish a baseline. The ATM was repeated after creation of a 1-cm supraspinatus tear, after creation of a 3-cm supraspinatus tear, and after repair with a transosseous equivalent (TOE) technique. Retroreflective bone markers and high-speed infrared cameras were used to measure GH kinematics and calculate the center of rotation of the GH joint (COR GH ) instantaneously. Results: The 1- and 3-cm supraspinatus tears did not significantly alter GH translation. The TOE repair shifted the COR GH posteriorly, as evidenced by a significant decrease in the overall GH translation in all 3 planes ( P = .003, .019, and .026, for x-y, y-z, and x-z planes, respectively). Conclusion: In contrast to a TOE repair of the supraspinatus tendon, isolated supraspinatus tears did not perturb GH kinematics in this cadaveric model of the throwing shoulder. Clinical Relevance: In throwing athletes, treatment of rotator cuff tears should be addressed with caution to avoid an unintended alteration in GH kinematics due to overtightening of the tendon.

24 July 2013 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
CRClaudio Rosso
Claudio Rosso
AMAndreas Mueller
Andreas Mueller
VEVahid Entezari
Vahid Entezari
WDWilliam A Dow
William A Dow
BMBrett McKenzie
Brett McKenzie
UCUgo Della Croce
Ugo Della Croce
Background: The shoulder has the greatest range of motion of any joint in the human body. This is due, in part, to the complex interplay between the glenohumeral (GH) joint and the scapulothoracic (ST) articulation. Currently, our ability to study shoulder kinematics is limited, because existing models isolate the GH joint and rely on manual manipulation to create motion, and have low reproducibility. Similarly, most established techniques track shoulder motion discontinuously with limited accuracy.Methods: To overcome these problems, we have designed a novel system in which the shoulder girdle is studied intact, incorporating both GH and ST motions. In this system, highly reproducible trajectories are created using a robotic actuator to control the intact shoulder girdle. High-speed cameras are employed to track retroreflective bone markers continuously.Results: We evaluated this automated system’s capacity to reproducibly capture GH translation in intact and pathologic shoulder conditions. A pair of shoulders (left and right) were tested during forward elevation at baseline, with a winged scapula, and after creation of a full thickness supraspinatus tear.Discussion: The system detected differences in GH translations as small as 0.5 mm between different conditions. For each, three consecutive trials were performed and demonstrated high reproducibility and high precision.

1 September 2020 in JSES International
Verified
Journal Article
Open access
DHDavid Hollo
David Hollo
CKChristoph Kolling
Christoph Kolling
LALaurent Audigé
Laurent Audigé
FMFabrizio Moro
Fabrizio Moro
DRDaniel Rikli
Daniel Rikli
AMAndreas Mueller
Andreas Mueller
The goal of this study was to evaluate whether plating and cortical bone grafting of shortened clavicular nonunions would restore clavicular length and enable bone healing. The association between the clavicular length difference (CLD) between sides and long-term functional outcome was also explored. For this retrospective 2-center study, patients who underwent plate fixation with cortical bone grafting of a clavicular nonunion were assessed after ≥2 years. The CLD and bone union were assessed using radiography and navigation ultrasound. The functional outcome was determined by the Constant score, Simple Shoulder Test score, and Subjective Shoulder Value, as well as local pain (0-10 numeric rating scale). Between 2 and 13 years after surgery, 25 patients (mean age, 53 years; 13 female patients) were examined. The median CLD was 0 mm (range, –17 to 13 mm) on ultrasound measurements and 2 mm (range, –32 to 9 mm) on radiographs. At follow-up, the median Constant score, Simple Shoulder Test score, Subjective Shoulder Value, and pain level were 82 points (range, 38-95 points), 12 points (range, 3-12 points), 95% (range, 60%-100%), and 0 (range, 0-8), respectively. There was no correlation between the CLD and all functional outcome scores. Bone union was achieved in all patients. After plate removal, 4 refractures occurred, 3 of which required revision. Plate fixation with cortical bone grafting of clavicular nonunions is associated with restoration of clavicular length and a high rate of bone union. There is, however, a considerable risk of refracture following plate removal. There was no association between the CLD and clinical outcome.

11 August 2025 in Journal of Biomechanics
Verified
Journal Article
Open access
ECEleonora Croci
Eleonora Croci
CKChristoph Künzel
Christoph Künzel
DGDominic Gehring
Dominic Gehring
AMAndreas Mueller
Andreas Mueller
Annegret MündermannAnnegret Mündermann
Annegret Mündermann
While markerless motion capture system has recently gained interest, little is known on the accuracy of Theia 3D for measuring shoulder kinematics. This study aimed to compare shoulder kinematics across the full range of arm motion between Theia 3D and a gold standard marker-based motion capture system. Shoulder kinematics of 20 healthy subjects were measured during three repetitions of bilateral full arm scaption, abduction, flexion, internal rotation, external rotation, and internal and external rotation at 90° abduction. Data were simultaneously collected with Theia 3D (v2024.1.24) markerless and marker-based motion capture. Markerless and marker-based angular trajectories had similar patterns, with larger differences towards the inflection point of the movements and with the markerless trajectories having mostly greater values than marker-based trajectories. Root mean square differences were smallest for abduction angles (0.75), but CMC was moderate (0.65-0.75) for flexion angles during rotation at 90° and weak (<0.65) for flexion angles during external rotation. For almost all tasks, the ranges of motion differed significantly between the two measurement systems in all three planes. However, mean differences in the coronal plane and in the sagittal plane were within the minimal clinically important differences. We found moderate to very strong correlations between the range of motion parameters of the two measurement methods. The assessment of shoulder kinematics with Theia 3D is promising but further improvements are needed for clinical routine application.