Surface flashover in vacuum imposes a substantial physical limit on modern, large-scale pulsed power. One of the ramifications is a minimum size requirement for new machines, which in itself becomes a hard barrier to the modernization and improvement of existing infrastructure. Pulsed power topologies require the physical mechanisms of both anode- and cathode-initiated flashover to be considered. Originally, the geometrical implications of field emission at the cathode triple junction (CTJ) motivated the usage of configurations that avoid electrons impinging on the insulating material. This will largely suppress the cathode-initiated flashover, which is best described by the secondary electron avalanche mechanism, gas desorption, and final breakdown in the desorbed gas. It depends on the cascade growth of a conducting plasma along the length of the insulator from the cathode. Mitigating the cathode-initiated flashover typically comes at the cost of a significant field enhancement at the anode triple junction (ATJ). In a typical implementation, the anode field may be three times higher than the cathode field for a given voltage, making the corresponding anode-initiated flashover much more common than otherwise. In the case of pulsed, anode-initiated flashover, experimental evidence suggests that charge is directly extracted from the insulator resulting in the insulator taking on a net positive charge advancing the anode potential. Along with accompanying gas desorption from the surface, the potential will then propagate from the anode toward the cathode until the effective length of the gap is sufficiently reduced to support flashover. The underlying physical mechanisms of cathode- and anode-directed flashover are discussed in light of previously gathered experimental data and recent experiments with pulsed, high-gradient, anode-initiated flashover.
Time-resolved optical emission spectroscopy is used to explore the early development of anode-initiated flashover in vacuum. An experimental apparatus for collecting flashover self-luminosity is introduced, which enables spatially resolved light collection from regions adjacent to the anode and cathode triple junctions. The emitted light is spectrally and temporally resolved utilizing an imaging spectrograph and a fast electronic shutter camera. The first light detectable from flashovers across both Rexolite and polytetrafluoroethylene (PTFE) insulators begins less than 10 ns prior to the flashover gap's impedance collapse and consists of faint broadband feature in primarily visible wavelengths. This suggests luminosity due to excitation in the solid, possibly occurring as a result of field emitted electrons. In the few nanoseconds leading up to and including the impedance collapse, the broadband spectrum grows in intensity and extends into the UV, eventually accompanied by a few emission lines of the insulator material. This is strong evidence that the early stages of anode-initiated flashover include surface layer breakdown of the insulator, as a contrast from cathode-initiated flashover, which is predominately an above-surface process. Spectra accumulated over longer exposures of PTFE flashovers indicate that, in the first few hundred nanoseconds after the impedance collapse, ions from the insulator material constitute the majority of the emission lines. Later, neutral and ionic metal species from the electrode contribute with similar prominence as well as molecular bands from diatomic carbon. Finally, a comparison is provided of the results of these studies to other spectroscopic investigations of vacuum flashover from the literature.
This manuscript reports the experimental study of a novel vacuum high-voltage (HV) feedthrough geometry with a recessed anode triple junction (ATJ) relevant to large-scale pulsed power systems. It is shown experimentally that introducing a vacuum gap between the insulator–anode interface and recessing the ATJ farther away from the cathode triple junction significantly enhances high voltage (HV) vacuum surface flashover hold-off. The results for “first pulse” and “consecutive pulse” tests are reported. The physical mechanisms contributing to the electrical failure of this feedthrough geometry appear to be unique to this geometry. These findings show the potential to allow for HV vacuum surface flashover geometries with significantly improved electrical characteristics.
25 May 2026 in IEEE Transactions on Dielectrics and Electrical Insulation
Pulsed electron field emission is measured from an assortment of plastic insulators with various surface preparations. The emission is markedly stochastic in nature. Generally, there is a spatially diffuse, baseline level of emission which is observed after a few repeated pulses on a sample. Additionally, localized, highly emissive sites contribute sporadically, with the estimated current for those excitations sometimes exceeding the baseline emission by orders of magnitude. Under 40 ns pulse excitation, Rexolite® produces measurable currents spanning from tens of nA up to hundreds of μA. These measurements mark a first step towards understanding initial plasma formation in anode-initiated vacuum flashover.
24 May 2021 in Propellants, Explosives, Pyrotechnics
This study presents a comprehensive investigation of electrode erosion and discharge behavior in spark gap switches over long switching cycle lifetimes. Brass, copper–tungsten (CuW), and stainless steel electrodes are tested under controlled conditions to quantify material degradation, debris accumulation, and changes in breakdown voltage. High-resolution imaging and statistical analysis of spark channel locations and gap breakdown voltages reveal how surface evolution influences long-term performance and reliability. These results provide essential data for lifetime modeling and inform design strategies for pulsed power systems in emerging applications such as private sector fusion energy and large-scale facilities like Sandia’s Z Machine and proposed ZX upgrades, where high repetition reliability and predictable behavior are critical.