19 May 2022 in IEEE Transactions on Plasma Science
Surface flashover in vacuum imposes a substantial physical limit on modern, large-scale pulsed power. One of the ramifications is a minimum size requirement for new machines, which in itself becomes a hard barrier to the modernization and improvement of existing infrastructure. Pulsed power topologies require the physical mechanisms of both anode- and cathode-initiated flashover to be considered. Originally, the geometrical implications of field emission at the cathode triple junction (CTJ) motivated the usage of configurations that avoid electrons impinging on the insulating material. This will largely suppress the cathode-initiated flashover, which is best described by the secondary electron avalanche mechanism, gas desorption, and final breakdown in the desorbed gas. It depends on the cascade growth of a conducting plasma along the length of the insulator from the cathode. Mitigating the cathode-initiated flashover typically comes at the cost of a significant field enhancement at the anode triple junction (ATJ). In a typical implementation, the anode field may be three times higher than the cathode field for a given voltage, making the corresponding anode-initiated flashover much more common than otherwise. In the case of pulsed, anode-initiated flashover, experimental evidence suggests that charge is directly extracted from the insulator resulting in the insulator taking on a net positive charge advancing the anode potential. Along with accompanying gas desorption from the surface, the potential will then propagate from the anode toward the cathode until the effective length of the gap is sufficiently reduced to support flashover. The underlying physical mechanisms of cathode- and anode-directed flashover are discussed in light of previously gathered experimental data and recent experiments with pulsed, high-gradient, anode-initiated flashover.
1 March 2024 in Physics of Plasmas
Time-resolved optical emission spectroscopy is used to explore the early development of anode-initiated flashover in vacuum. An experimental apparatus for collecting flashover self-luminosity is introduced, which enables spatially resolved light collection from regions adjacent to the anode and cathode triple junctions. The emitted light is spectrally and temporally resolved utilizing an imaging spectrograph and a fast electronic shutter camera. The first light detectable from flashovers across both Rexolite and polytetrafluoroethylene (PTFE) insulators begins less than 10 ns prior to the flashover gap's impedance collapse and consists of faint broadband feature in primarily visible wavelengths. This suggests luminosity due to excitation in the solid, possibly occurring as a result of field emitted electrons. In the few nanoseconds leading up to and including the impedance collapse, the broadband spectrum grows in intensity and extends into the UV, eventually accompanied by a few emission lines of the insulator material. This is strong evidence that the early stages of anode-initiated flashover include surface layer breakdown of the insulator, as a contrast from cathode-initiated flashover, which is predominately an above-surface process. Spectra accumulated over longer exposures of PTFE flashovers indicate that, in the first few hundred nanoseconds after the impedance collapse, ions from the insulator material constitute the majority of the emission lines. Later, neutral and ionic metal species from the electrode contribute with similar prominence as well as molecular bands from diatomic carbon. Finally, a comparison is provided of the results of these studies to other spectroscopic investigations of vacuum flashover from the literature.
1 August 2024 in Physics of Plasmas
This manuscript reports the experimental study of a novel vacuum high-voltage (HV) feedthrough geometry with a recessed anode triple junction (ATJ) relevant to large-scale pulsed power systems. It is shown experimentally that introducing a vacuum gap between the insulator–anode interface and recessing the ATJ farther away from the cathode triple junction significantly enhances high voltage (HV) vacuum surface flashover hold-off. The results for “first pulse” and “consecutive pulse” tests are reported. The physical mechanisms contributing to the electrical failure of this feedthrough geometry appear to be unique to this geometry. These findings show the potential to allow for HV vacuum surface flashover geometries with significantly improved electrical characteristics.
7 May 2020 in IEEE Transactions on Plasma Science
A 3-D Monte Carlo-type random walk model was constructed for the assessment of lightning attachment probabilities to small structures. The simulation assumed buildings had a negligible impact on the propagation of lightning. A purely stochastic propagation model based on a previously proposed gas and charged particle diffusion process was employed. The attachment was based on the electrogeometric model in which striking distance is determined by return stroke peak current. This model allows for hundreds of thousands of samples to be evaluated in the window of a few minutes on readily available consumer computing hardware. Using this model, it became possible to enable characterizing building protection as a probability distribution of striking distance. Such was done to provide a deeper understanding of the impact of building protection design choices than is readily available from binary testing. The model was calibrated for minimum input resolution, which is found to be insensitive to variations in step length and moderately insensitive to variations in propagation angle distribution, resulting in normalized errors of less than 15% (rms). A parametric sweep of geometric features was performed for a large (100 m x 50 m) rectangular building with catenary wire protection. For heights of less than 30 m, lightning was found to bypass protection structures and strike to the building itself at rates that were insensitive to variations in building height. The extent to which the protection may be recessed from the building's perimeter was found to have a significant impact. Variations in building aspect ratio were found to be of limited impact except for cases of extreme aspect ratio where competition with the ground appears to have resulted in much better lightning protection performance.
29 December 2021 in IEEE Transactions on Plasma Science
Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 Ω or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.