Khudoyorkhon Muzaffar uglu Jamolov

Prof. Khudoyorkhon Muzaffar uglu Jamolov

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2025
Verified
Book Chapter
Closed access
PDF file
RFRajabov Farkhat
Rajabov Farkhat
DJDjumanov Jamoljon
Djumanov Jamoljon
AKAbdurashidova Kamola
Abdurashidova Kamola
KJKhudoyorkhon Muzaffar uglu Jamolov
Khudoyorkhon Muzaffar uglu Jamolov

9 June 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ABAbror Buriboev
Abror Buriboev
FRFarkhat Farmanovich Rajabov
Farkhat Farmanovich Rajabov
DJDjumanov Xudaykulovich Jamoljon
Djumanov Xudaykulovich Jamoljon
KJKhudoyorkhon Muzaffar uglu Jamolov
Khudoyorkhon Muzaffar uglu Jamolov
AAAkmal Abduvaitov
Akmal Abduvaitov
CLCheolwon Lee
Cheolwon Lee
Accurate and reliable groundwater-level monitoring in deep observation wells remains difficult for conventional non-contact ultrasonic systems because narrow tubular geometries intensify multipath reflections, signal attenuation, and echo ambiguity. This study proposes a dual-signal direct time-of-flight (ToF) method that combines radiofrequency (RF) synchronization with one-way airborne ultrasonic propagation to a floating receiver located at the groundwater surface. In the proposed architecture, the RF signal provides a near-instantaneous time reference, whereas the ultrasonic signal defines the propagation delay, thereby eliminating dependence on echo-based ranging. The system integrates a wellhead surface unit for synchronized transmission and control, a floating unit for ToF acquisition and embedded processing, and an optional reference channel for in situ estimation of the effective sound speed. A duty-cycled power architecture is used to support low-power long-term deployment, while a multi-shot acquisition strategy with a median-like estimator improves robustness against startup transients, timing jitters, and false detections. Field validation was conducted over a 12-month period under actual groundwater-monitoring conditions, during which the groundwater depth varied between 14 m and 30 m below the wellhead datum. Within this field-validation interval, the proposed system achieved a mean absolute error of 0.048 m, a maximum absolute error of 0.050 m, and an overall valid detection rate of 99.4% over 358 valid cycles out of 360 scheduled cycles. In addition, a separate range-dependent confined-tubular propagation test was conducted to evaluate the extended detection capability of the RF-synchronized one-way ultrasonic ToF architecture. This test demonstrated stable acoustic-link ToF detection up to 300 m inside the tested 170 mm confined plastic pipeline. Therefore, the 300 m result should be interpreted as a range-dependent valid-detection result rather than as a 12-month groundwater-depth validation over the full 300 m interval. These results demonstrate that the proposed direct-ToF method provides an RF-synchronized one-way ultrasonic ToF framework with a floating receiver for groundwater-level monitoring in deep observation wells, while remaining compatible with low-power and IoT-based environmental monitoring systems.