Background—: Conducting channels are the target for ventricular tachycardia (VT) ablation. Conducting channels could be identified with contrast enhanced–cardiac magnetic resonance (ce-CMR) as border zone (BZ) corridors. A 3-dimensional (3D) reconstruction of the ce-CMR could allow visualization of the 3D structure of these BZ channels. Methods and Results—: We included 21 patients with healed myocardial infarction and VT. A 3D high-resolution 3T ce-CMR was performed before CARTO-guided VT ablation. The left ventricular wall was segmented and characterized using a pixel signal intensity algorithm at 5 layers (endocardium, 25%, 50%, 75%, epicardium). A 3D color-coded shell map was obtained for each layer to depict the scar core and BZ distribution. The presence/characteristics of BZ channels were registered for each layer. Scar area decreased progressively from endocardium to epicardium (scar area/left ventricular area: 34.0±17.4% at endocardium, 24.1±14.7% at 25%, 16.3±12.1% at 50%, 13.1±10.4 at 75%, 12.1±9.3% at epicardium; P <0.01). Forty-five BZ channels (2.1±1.0 per patient, 23.7±12.0 mm length, mean minimum width 2.5±1.5 mm) were identified, 85% between the endocardium and 50% shell and 76% present in ≥1 layer. The ce-CMR–defined BZ channels identified 74% of the critical isthmus of clinical VTs and 50% of all the conducting channels identified in electroanatomic maps. Conclusions—: Scar area in patients with healed myocardial infarction decreases from the endocardium to the epicardium. BZ channels, more commonly seen in the endocardium, display a 3D structure within the myocardial wall that can be depicted with ce-CMR. The use of ce-CMR–derived maps to guide VT ablation warrants further investigation.
1 October 2011 in Circulation: Arrhythmia and Electrophysiology
Background—: Scar heterogeneity identified with contrast-enhanced cardiac magnetic resonance (CE-CMR) has been related to its arrhythmogenic potential by using different algorithms. The purpose of the study was to identify the algorithm that best fits with the electroanatomic voltage maps (EAM) to guide ventricular tachycardia (VT) ablation. Methods and Results—: Three-dimensional scar reconstructions from preprocedural CE-CMR study at 3T were obtained and compared with EAMs of 10 ischemic patients submitted for a VT ablation. Three-dimensional scar reconstructions were created for the core (3D-CORE) and border zone (3D-BZ), applying cutoff values of 50%, 60%, and 70% of the maximum pixel signal intensity to discriminate between core and BZ. The left ventricular cavity from CE-CMR (3D-LV) was merged with the EAM, and the 3D-CORE and 3D-BZ were compared with the corresponding EAM areas defined with standard cutoff voltage values. The best match was obtained when a cutoff value of 60% of the maximum pixel signal intensity was used, both for core ( r2 =0.827; P <0.001) and BZ ( r2 =0.511; P =0.020), identifying 69% of conducting channels (CC) observed in the EAM. Matching improved when only the subendocardial half of the wall was segmented (CORE: r2 =0.808; P <0.001 and BZ: r2 =0.485; P =0.025), identifying 81% of CC. When comparing the location of each bipolar voltage intracardiac electrogram with respect to the 3D CE-CMR–derived structures, a Cohen κ coefficient of 0.70 was obtained. Conclusions—: Scar characterization by means of high resolution CE-CMR resembles that of EAM and can be integrated into the CARTO system to guide VT ablation.
This paper presents a new registration algorithm, called Temporal Diffeomorphic Free Form Deformation (TDFFD), and its application to motion and strain quantification from a sequence of 3D ultrasound (US) images. The originality of our approach resides in enforcing time consistency by representing the 4D velocity field as the sum of continuous spatiotemporal B-Spline kernels. The spatiotemporal displacement field is then recovered through forward Eulerian integration of the non-stationary velocity field. The strain tensor is computed locally using the spatial derivatives of the reconstructed displacement field. The energy functional considered in this paper weighs two terms: the image similarity and a regularization term. The image similarity metric is the sum of squared differences between the intensities of each frame and a reference one. Any frame in the sequence can be chosen as reference. The regularization term is based on the incompressibility of myocardial tissue. TDFFD was compared to pairwise 3D FFD and 3D+t FFD, both on displacement and velocity fields, on a set of synthetic 3D US images with different noise levels. TDFFD showed increased robustness to noise compared to these two state-of-the-art algorithms. TDFFD also proved to be more resistant to a reduced temporal resolution when decimating this synthetic sequence. Finally, this synthetic dataset was used to determine optimal settings of the TDFFD algorithm. Subsequently, TDFFD was applied to a database of cardiac 3D US images of the left ventricle acquired from 9 healthy volunteers and 13 patients treated by Cardiac Resynchronization Therapy (CRT). On healthy cases, uniform strain patterns were observed over all myocardial segments, as physiologically expected. On all CRT patients, the improvement in synchrony of regional longitudinal strain correlated with CRT clinical outcome as quantified by the reduction of end-systolic left ventricular volume at follow-up (6 and 12months), showing the potential of the proposed algorithm for the assessment of CRT.
8 May 2018 in International Journal for Numerical Methods in Biomedical Engineering
According to clinical studies, around one third of patients with atrial fibrillation (AF) will suffer a stroke during their lifetime. Between 70 and 90% of these strokes are caused by thrombus formed in the left atrial appendage. In patients with contraindications to oral anticoagulants, a left atrial appendage occluder (LAAO) is often implanted to prevent blood flow entering in the LAA. A limited range of LAAO devices is available, with different designs and sizes. Together with the heterogeneity of LAA morphology, these factors make LAAO success dependent on clinician's experience. A sub-optimal LAAO implantation can generate thrombi outside the device, eventually leading to stroke if not treated. The aim of this study was to develop clinician-friendly tools based on biophysical models to optimize LAAO device therapies. A web-based 3D interactive virtual implantation platform, so-called VIDAA, was created to select the most appropriate LAAO configurations (type of device, size, landing zone) for a given patient-specific LAA morphology. An initial LAAO configuration is proposed in VIDAA, automatically computed from LAA shape features (centreline, diameters). The most promising LAAO settings and LAA geometries were exported from VIDAA to build volumetric meshes and run Computational Fluid Dynamics (CFD) simulations to assess blood flow patterns after implantation. Risk of thrombus formation was estimated from the simulated hemodynamics with an index combining information from blood flow velocity and complexity. The combination of the VIDAA platform with in silico indices allowed to identify the LAAO configurations associated to a lower risk of thrombus formation; device positioning was key to the creation of regions with turbulent flows after implantation. Our results demonstrate the potential for optimizing LAAO therapy settings during pre-implant planning based on modeling tools and contribute to reduce the risk of thrombus formation after treatment.
There is insufficient evidence to implant a combined cardiac resynchronization therapy (CRT) device with defibrillation capabilities (CRT-D) in all CRT candidates. The aim of the study was to assess myocardial scar size and its heterogeneity as predictors of sudden cardiac death (SCD) in CRT candidates. A cohort of 78 consecutive patients with dilated cardiomyopathy and class I indication for CRT-D were prospectively enrolled. Before CRT-D implantation, a contrast-enhanced cardiac magnetic resonance (ce-CMR) was performed. The core and border zone (BZ) of the myocardial scar were characterized and quantified with a customized post-processing software. The first appropriate implantable cardioverter defibrillator (ICD) therapy was considered as a surrogate of SCD. During a mean follow-up of 25 months (25–75th percentiles, 15–34), appropriate ICD therapy occurred in 11.5% of patients. In a multivariate Cox proportional hazards regression model for clinical and ce-CMR variables, the scar mass percentage [hazards ratio (HR) per 1% increase 1.1 (1.06–1.15), P < 0.01], the BZ mass [HR per 1 g increase 1.06 (1.04–1.09), P < 0.01], and the BZ percentage of the scar [HR per 1% increase 1.06 (1.02–1.11), P < 0.01], were the only independent predictors of appropriate ICD therapy. Receiver-operating characteristic curve analysis showed that a scar mass <16% and a BZ < 9.5 g had a negative predictive value of 100%. The presence, size, and heterogeneity of myocardial scar independently predict appropriate ICD therapies in CRT candidates. The ce-CMR-based scar analysis might help identify a subgroup of patients at relatively low risk of SCD.