Background/Objectives: Computer-assisted posturography is utilized to quantify human postural control, yet existing dedicated systems frequently present physical constraints, such as limited sensing surfaces and rigid hardware barriers. In this study, a methodological framework is presented and a structural arrangement (OpenBalance) is designed to implement balance assessment accommodating a wider anthropometric range through zone-based foot placement using a decentralized load cell array, with preliminary implementation details provided in a repository. Methods: The configuration comprises an array of 16 discrete uniaxial vertical-force load cells embedded within four mechanically decoupled sub-platforms to minimize mechanical cross-talk. Biomechanical moment equations were implemented in a custom Python pipeline to compute a localized Center of Pressure (COP) for each sub-platform independently. A vector-based data fusion algorithm maps these local coordinates into a unified global coordinate system. The system evaluation incorporated baseline signal-to-noise ratio (SNR) analysis, mechanical crosstalk testing, and digital low-pass filtering. Results: A proof-of-concept evaluation using empirical data confirmed that the cascading coordinate model produces a continuous global COP trajectory and quadrant-specific load distributions. The platform dimensions (355 × 460 mm) and sensor topography geometrically accommodate natural external foot rotation (incorporating a 10° toe-out angle projection) and foot lengths corresponding to EU shoe sizes up to 55. Mechanical crosstalk between adjacent sub-platforms remained minimal (<1% of applied load). Conclusions: The OpenBalance framework confirms the technical feasibility of deriving a continuous global COP from a decentralized array of distributed load cells. While baseline component specifications and static verifications are established, comprehensive dynamic cross-validation against reference standards remains a necessary next step for the future development of open hardware that can be produced using 3D printing.
Background/Objectives: Computer-assisted dynamic posturography is central to quan-tifying human postural control, yet many commercial systems often impose physical constraints such as small sensing surfaces that restrict larger foot sizes, high costs, and limited data interoperability arising from proprietary hardware and software. This study introduces a methodological framework and open-platform architecture (“OpenBal-ance”) intended to broaden access to mobile balance assessment by enabling uncon-strained foot placement. Methods: The proposed configuration uses an array of 16 dis-crete vertical-force load cells embedded in four mechanically decoupled sub-platforms intended to limit cross-talk and shear-force distortion. Biomechanical moment equations were implemented in a custom Python pipeline to compute a localized Center of Pressure (COP) for each sub-platform independently of weight shifts. A vector-based, ele-ment-wise data fusion maps these coordinates into a unified global coordinate system, alongside a time-averaged Weight Distribution Index (WDI). Results: A proof-of-concept trial using raw, unfiltered empirical data demonstrated that the cascading coordinate model produces a coherent global COP trajectory and per-quadrant load distribution, visualized with standard scientific Python libraries. The platform dimensions (355×460 mm) and sensor topography geometrically accommodate unconstrained external foot rotation and foot lengths corresponding to EU shoe sizes up to 55. Conclusions: The OpenBalance architecture indicates that a decentralized, cost-effective approach to pos-turography is feasible and can produce a continuous global COP from distributed load cells. Formal calibration and metrological validation against a reference standard remain necessary next steps. Future research should use this hardware-agnostic platform to develop structured, multi-sensory perturbation sequences to isolate discrete neu-ro-feedback loops in athletic and clinical cohorts.
Human postural control assessment is currently characterized by methodological inconsistencies in data processing, measurement protocols, and spatial sway area calculations, often resulting in potential ceiling effects when evaluating cohorts with high baseline balance stability. To address these limitations, we developed OpenBalance, an interoperable, open-source Python framework designed to standardize signal processing across diverse commercial and custom force plate formats. Alongside this computational architecture, we propose a progressive 8-stage measurement protocol designed to scale postural difficulty and introduce a dimensionless metric, the Outlier Excursion Ratio (OER). The OER mathematically leverages the spatial disparity between the Convex Hull Area and the 95% Prediction Ellipse Area to quantify extreme spatial trajectory excursions. A single-subject dataset was processed as a technical proof-of-concept to verify the software pipeline’s execution and parameter calculation under empirical measurement conditions. Furthermore, automated extraction demonstrated the OER to be mathematically sensitive to transient spatial trajectory excursions, illustrating the methodological inconsistencies of comparing ambiguous sway area metrics across studies. By shifting from rigid data-upload services to an adaptable modular library, the OpenBalance framework provides an open-access infrastructure to support standardized signal processing and reproducible data analysis.