Yanju Li

Yanju Li


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CCCong Chen
Cong Chen
XWXiaojian Wang
Xiaojian Wang
YLYanju Li
Yanju Li
QCQichao Chen
Qichao Chen
To address the limited spatial localization accuracy of partial discharge (PD) in high-voltage cable terminations and the difficulty in accurately determining the trigger time in traditional ultrasonic detection, this paper proposes an electro-acoustic synergistic localization technology based on a high-frequency current transformer (HFCT) and a Sagnac optical fiber interferometer. A high-sensitivity Sagnac acoustic sensor based on a 3D-printed photosensitive resin mandrel was developed. Through structural design and 0–50 kHz amplitude–frequency testing, the sensor exhibits a dominant resonant response at 33.2 kHz. This narrow-band, high-sensitivity characteristic effectively enhances the perception capability for weak PD ultrasonic signals. An electro-acoustic synergistic detection system was constructed, in which the high-frequency PD current signal captured by the HFCT was used as the electrical time reference, and a dual-channel Sagnac sensor array was used to extract the arrival times of ultrasonic waves. In a 12 kV laboratory cable-termination PD experiment, the proposed system identified the representative built-in air-gap PD source with an absolute localization error of 5 mm under the tested laboratory configuration. This value should be interpreted as the localization result for the tested representative defect, rather than as a generally validated accuracy specification of the system. This study provides a proof-of-concept laboratory demonstration of an electro-acoustic localization strategy that combines the fast electrical response of HFCT detection with the electromagnetic-interference immunity and acoustic sensitivity of Sagnac fiber-optic sensing.

1 July 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
SBShiguang Bai
Shiguang Bai
ZLZhongyuan Li
Zhongyuan Li
YLYanju Li
Yanju Li
QCQichao Chen
Qichao Chen
To address the structural complexity, limited detection sensitivity, and environmental susceptibility of the stable operating point in conventional fiber-optic current transformers for low-current detection, this study proposes a fiber-optic current transformer based on the coupling of an extrinsic Fabry–Perot interferometer (EFPI) and a lead zirconate titanate piezoelectric ceramic (PZT). In the proposed sensor, a toroidal magnetic core and an induction winding are used as the current pickup unit to convert the measured alternating current into an induced voltage. This induced voltage directly drives the PZT to generate axial displacement, causing periodic variations in the length of the air Fabry–Perot cavity formed between the fiber end face and the coated quartz diaphragm. As a result, the current signal is converted into an optical interference intensity signal. To prevent the static operating point from deviating from the optimal linear region during EFPI intensity demodulation, a DC-component-feedback-based operating point control method is proposed. By adjusting the driving voltage of the fiber Fabry–Perot tunable filter, the center wavelength of the incident narrowband demodulation light can track the optimal operating point of the interference spectrum, thereby improving the stability of the intensity demodulation process. Experimental results show that the fabricated sensor can generate a stable reflected interference spectrum and exhibits a relatively flat frequency response within the range of 0–7 kHz, indicating its potential for power-frequency current detection under the present laboratory conditions. When the measured current is 0.13 mA, the sensor can still produce a distinguishable sinusoidal output signal. When the measured current increases to 75 mA, obvious nonlinear distortion appears in the output signal, indicating that the sensor is approaching the boundary of its linear detection range. Within the linear operating region, the output peak-to-peak value shows good linearity with the measured current. The results indicate that the proposed EFPI-PZT fiber-optic current transformer has the advantages of a relatively simple structure, clear low-current response, and adjustable structural parameters, providing a reference for the miniaturized design and further development of new fiber-optic current sensors.