Qichao Chen

Dr. Qichao Chen

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in Sensors
Verified
Journal Article
Open access
JWJinlong Wang
Jinlong Wang
WSWeizhong Sun
Weizhong Sun
JZJun Zhou
Jun Zhou
LWLei Wang
Lei Wang
LCLianfei Chen
Lianfei Chen
WZWei-Chao Zhang
Wei-Chao Zhang
This study addresses the challenges of electromagnetic interference and unstable signal transmission encountered by traditional sensors in detecting partial discharge (PD) within stator slots of large motors. A novel Extrinsic Fabry–Perot Interferometer (EFPI) sensor with a vibration-coupling air gap was designed to enhance the narrowband resonant detection sensitivity for PD ultrasonic signals by optimizing the diaphragm structure and coupling interface. The sensor features a quartz diaphragm with a thickness of 20 μM, an effective constrained radius of 0.9 mm, a vibration-coupling air gap depth of 100 μM, and a first-order natural resonant frequency of 66 kHz. Simulation and experimental analyses revealed the distribution characteristics and propagation paths of ultrasonic signals within stator slots. The results demonstrate that the EFPI sensor effectively detects PD ultrasonic signals at its resonant frequency of 66 kHz with a localization error of less than 5 mm, meeting engineering requirements. This study provides theoretical and practical insights into the efficient detection and precise localization of insulation faults in large motor stators.

15 April 2025 in Sensors
Verified
Journal Article
Open access
PDF file
CCCong Chen
Cong Chen
ZLZhongyuan Li
Zhongyuan Li
QCQichao Chen
Qichao Chen
WZWei-Chao Zhang
Wei-Chao Zhang
Aiming at the issues of low sensitivity and poor resistance to temperature and vibration interference in traditional optical fiber current transformers, as well as the structural complexity of magnetostrictive material-coupled sensors, this paper integrates a high-sensitivity electrostrictive piezoelectric ceramic sensor with an FBG-FP cascaded fiber-optic sensor. This coupling significantly optimizes the sensor structure. By employing orthogonal intensity demodulation to enhance detection sensitivity, and adopting a multi-cycle waveform-averaging method to calculate the DC output light intensity, temperature calibration and compensation are achieved through the correlation between the DC output light intensity and operating points. Experimental results demonstrate that the designed sensor exhibits a detection bandwidth of 0–7 kHz, fully meeting the requirements for power-frequency current detection. Its current measurement range spans 0.15–42 mA, with a minimum measurable current as low as 150 μA. This study provides a compact, high-precision, highly scalable, and adaptable current detection solution for power systems, demonstrating significant engineering application value.

30 May 2026 in Sensors
Verified
Journal Article
Open access
PDF file
CCCong Chen
Cong Chen
XWXiaojian Wang
Xiaojian Wang
YLYanju Li
Yanju Li
QCQichao Chen
Qichao Chen
To address the limited spatial localization accuracy of partial discharge (PD) in high-voltage cable terminations and the difficulty in accurately determining the trigger time in traditional ultrasonic detection, this paper proposes an electro-acoustic synergistic localization technology based on a high-frequency current transformer (HFCT) and a Sagnac optical fiber interferometer. A high-sensitivity Sagnac acoustic sensor based on a 3D-printed photosensitive resin mandrel was developed. Through structural design and 0–50 kHz amplitude–frequency testing, the sensor exhibits a dominant resonant response at 33.2 kHz. This narrow-band, high-sensitivity characteristic effectively enhances the perception capability for weak PD ultrasonic signals. An electro-acoustic synergistic detection system was constructed, in which the high-frequency PD current signal captured by the HFCT was used as the electrical time reference, and a dual-channel Sagnac sensor array was used to extract the arrival times of ultrasonic waves. In a 12 kV laboratory cable-termination PD experiment, the proposed system identified the representative built-in air-gap PD source with an absolute localization error of 5 mm under the tested laboratory configuration. This value should be interpreted as the localization result for the tested representative defect, rather than as a generally validated accuracy specification of the system. This study provides a proof-of-concept laboratory demonstration of an electro-acoustic localization strategy that combines the fast electrical response of HFCT detection with the electromagnetic-interference immunity and acoustic sensitivity of Sagnac fiber-optic sensing.

10 February 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
QCQichao Chen
Qichao Chen
MXMengze Xu
Mengze Xu
ZLZhongyuan Li
Zhongyuan Li
CCCong Chen
Cong Chen
WZWei-Chao Zhang
Wei-Chao Zhang
In response to the key issues of complex internal structure, significant attenuation of partial discharge (PD) ultrasound signal propagation, and low sensor sensitivity in large oil–immersed power transformers, this paper analyzes the multi–order resonant mode vibration characteristics of the shaft–type fiber optic ultrasound sensor core structure. The displacement distribution patterns of the core structure in both transverse and longitudinal resonant modes are clarified. A strategy using oblique fiber winding rings is proposed to eliminate the problems of strain cancellation and non–accumulation of displacement in transverse and longitudinal resonant modes, which are common in traditional fiber optic ultrasound sensors with parallel fiber windings. Furthermore, design principles are provided to enhance the coverage of the free end and the high–strain regions with semi–high symmetry, as well as the vector–integrated response suitable for multi–order modes. Experimental results show that, in typical PD model detection, the oblique winding sensor exhibits a more prominent response near the high–order resonances of the core, with a detection sensitivity approximately 2.5 times higher than that of the parallel winding structure, and an overall sensitivity at least 7.4 times greater than that of traditional Piezoelectric (PZT) sensors. This demonstrates that the fiber winding method is a key design parameter determining the acoustic–solid coupling efficiency and high sensitivity performance of shaft–type fiber optic interferometric PD sensors, providing a feasible path for high–reliability fiber optic sensing solutions for online monitoring of transformer partial discharges.

1 July 2026 in Micromachines
Verified
Journal Article
Open access
PDF file
SBShiguang Bai
Shiguang Bai
ZLZhongyuan Li
Zhongyuan Li
YLYanju Li
Yanju Li
QCQichao Chen
Qichao Chen
To address the structural complexity, limited detection sensitivity, and environmental susceptibility of the stable operating point in conventional fiber-optic current transformers for low-current detection, this study proposes a fiber-optic current transformer based on the coupling of an extrinsic Fabry–Perot interferometer (EFPI) and a lead zirconate titanate piezoelectric ceramic (PZT). In the proposed sensor, a toroidal magnetic core and an induction winding are used as the current pickup unit to convert the measured alternating current into an induced voltage. This induced voltage directly drives the PZT to generate axial displacement, causing periodic variations in the length of the air Fabry–Perot cavity formed between the fiber end face and the coated quartz diaphragm. As a result, the current signal is converted into an optical interference intensity signal. To prevent the static operating point from deviating from the optimal linear region during EFPI intensity demodulation, a DC-component-feedback-based operating point control method is proposed. By adjusting the driving voltage of the fiber Fabry–Perot tunable filter, the center wavelength of the incident narrowband demodulation light can track the optimal operating point of the interference spectrum, thereby improving the stability of the intensity demodulation process. Experimental results show that the fabricated sensor can generate a stable reflected interference spectrum and exhibits a relatively flat frequency response within the range of 0–7 kHz, indicating its potential for power-frequency current detection under the present laboratory conditions. When the measured current is 0.13 mA, the sensor can still produce a distinguishable sinusoidal output signal. When the measured current increases to 75 mA, obvious nonlinear distortion appears in the output signal, indicating that the sensor is approaching the boundary of its linear detection range. Within the linear operating region, the output peak-to-peak value shows good linearity with the measured current. The results indicate that the proposed EFPI-PZT fiber-optic current transformer has the advantages of a relatively simple structure, clear low-current response, and adjustable structural parameters, providing a reference for the miniaturized design and further development of new fiber-optic current sensors.

12 September 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YZYunpeng Zhan
Yunpeng Zhan
QCQichao Chen
Qichao Chen
SHShuai Hou
Shuai Hou
JLJie Liu
Jie Liu
YCYun Chen
Yun Chen
LLLiyong Lai
Liyong Lai
Partial discharge (PD) generates transient acoustic-vibration signals that can be used for the passive monitoring of cable insulation. Unlike previous studies that separately addressed DFB-FL sensitivity, polymer-property effects, or acoustic attenuation in a particular cable, this study establishes an application-oriented cross-scale assessment that links material-level propagation loss with cable-scale detection by a distributed feedback fiber laser (DFB-FL)/fiber Bragg grating (FBG) system. This study compared the Young’s moduli of polypropylene (PP), cross-linked polyethylene (XLPE), and methyl silicone rubber (MQ), and measured their frequency-dependent attenuation coefficients along with those of insulating oil in the range of 50 to 300 kHz. Subsequently, a 250 mm-long, 220 kV XLPE cable specimen containing a needle-induced artificial cavity was tested at sensing distances of 0–7 cm and at four circumferential positions. For the three tested materials, the extrapolated initial response amplitude decreased as the Young’s modulus increased. The measured polymer attenuation coefficients were approximately 0.052–0.192 Np/cm, compared with approximately 0.018–0.033 Np/cm for insulating oil. Under the stated laboratory criteria, the lowest time-correlated apparent-charge event detected by the DFB-FL system was 16 pC. The DFB-FL peak-to-peak response decreased from 5.04 Vpp at 0 cm to 1.00 Vpp at 7 cm, crossing below the background threshold between 6 and 7 cm, which experimentally verifies the intrinsic connection among material attenuation, internal cable propagation paths, and sensor-placement constraints.