Jae-Hyun Lee

Prof. Jae-Hyun Lee

Seoul National University School of Dentistry, Seoul, Republic of Korea
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in The Journal of Advanced Prosthodontics
Verified
Journal Article
Open access
PDF file
GMGerelmaa Myagmar
Gerelmaa Myagmar
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
JAJinsoo Ahn
Jinsoo Ahn
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
HYHyung-In Yoon
Hyung-In Yoon
JHJung-Suk Han
Jung-Suk Han
Myagmar G, et al. J Adv Prosthodont. 2021 Jun;13(3):144-151. https://doi.org/10.4047/jap.2021.13.3.144

8 August 2019 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
JYJe-Hyeon Yun
Je-Hyeon Yun
JHJung-Suk Han
Jung-Suk Han
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
HYHyung-In Yoon
Hyung-In Yoon
Research on whether the number or location of missing teeth affects the accuracy of intraoral scanners in partial edentulous patients is scarce. This study aimed to evaluate the precision of complete-arch scan data of various partial edentulous arches acquired by intraoral scanners. Five different maxillary models were scanned using Carestream CS3600 and Medit i500 scanners. The models employed here were control: Fully dentate; Case 1: Missing a right second premolar and a first molar; Case 2: Missing a right second premolar, a first molar, both left premolars, and a left first molar; Case 3: Missing four incisors and a right canine; and Case 4: Missing four incisors, a left second premolar, and a first molar. Six scans per group were performed and the resulting two datasets were paired to analyze the precision of each group (n = 15). Two-way ANOVA was performed (α = 0.05). The root mean square (RMS) error values in Cases 2, 3, and 4 were significantly higher than those in Case 1 and control. The RMS values of the two intraoral scanners were not significantly different. Scanning precision was significantly lower for both devices when used for scanning dental arches with ≥5 missing teeth.

22 December 2019 in Materials
Verified
Journal Article
Open access
PDF file
JKJung-Ju Kim
Jung-Ju Kim
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
JKJeong Chan Kim
Jeong Chan Kim
JLJun-Beom Lee
Jun-Beom Lee
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
The stability of peri-implant tissue is essential for the long-term success of dental implants. Although various types of implant connections are used, little is known about the effects of the physical mechanisms of dental implants on the stability of peri-implant tissue. This review summarizes the relevant literature to establish guidelines regarding the effects of connection type between abutments and implants in soft and hard tissues. Soft tissue seals can affect soft tissue around implants. In external connections, micromobility between the abutment and the hex component of the implant, resulting from machining tolerance, can destroy the soft tissue seal, potentially leading to microbial invasion. Internal friction connection implants induce strain on the surrounding bone via implant wall expansion that translates into masticatory force. This strain is advantageous because it increases the amount and quality of peri-implant bone. The comparison of internal and external connections, the two most commonly used connection types, reveals that internal friction has a positive influence on both soft and hard tissues.

1 January 2020 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
JLJungwon Lee
Jungwon Lee
SPSe-wook Pyo
Se-wook Pyo
HCHyun-Jae Cho
Hyun-Jae Cho
JAJung-Sub An
Jung-Sub An
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
YLYong-Moo Lee
Yong-Moo Lee
A stability-measuring device that utilizes damping capacity analysis (DCA) has recently been introduced in the field of dental implantology. This study aimed to evaluate the sensitivity and reliability of this device by measuring the implant stability of ex vivo samples in comparison with a resonance frequency analysis (RFA) device. Six implant beds were prepared in porcine ribs using 3 different drilling protocols to simulate various implant stability conditions. Thirty-six pork ribs and 216 bone-level implants measuring 10 mm in height were used. The implant beds were prepared using 1 of the following 3 drilling protocols: 10-mm drilling depth with a 3.5-mm-diameter twist drill, 5-mm drilling depth with a 4.0-mm-diameter twist drill, and 10-mm drilling depth with a 4.0-mm-diameter twist drill. The first 108 implants were external-connection implants 4.0 mm in diameter, while the other 108 implants were internal-connection implants 4.3 mm in diameter. The peak insertion torque (PIT) during implant placement, the stability values obtained with DCA and RFA devices after implant placement, and the peak removal torque (PRT) during implant removal were measured. The intraclass correlation coefficients (ICCs) of the implant stability quotient (ISQ) results obtained using the RFA device at the medial, distal, ventral, and dorsal points were 0.997, 0.994, 0.994, and 0.998, respectively. The ICCs of the implant stability test (IST) results obtained using the DCA device at the corresponding locations were 0.972, 0.975, 0.974, and 0.976, respectively. Logarithmic relationships between PIT and IST, PIT and ISQ, PRT and IST, and PRT and ISQ were observed. The mean absolute difference between the ISQ and IST values on a Bland-Altman plot was -6.76 (-25.05 to 11.53, P<0.05). Within the limits of ex vivo studies, measurements made using the RFA and DCA devices were found to be correlated under a variety of stability conditions.

27 September 2022 in Journal of Dental Sciences
Verified
Journal Article
Open access
SCSunyoung Choi
Sunyoung Choi
YJYe-Hyeon Jo
Ye-Hyeon Jo
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
HYHyung-In Yoon
Hyung-In Yoon
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
JHJung-Suk Han
Jung-Suk Han
Dental implants are inevitably exposed to bacteria in oral cavity. Understanding the colonization of bacteria on implant surface is necessary to prevent bacteria-related inflammation surrounding dental implants. The purpose of this study was to investigate the effect of surface properties on biofilm formation on the implant surface. One early colonizer, Streptococcus gordonii (S. gordonii), and two late colonizers, Fusobacterium nucleatum (F. nucleatum) and Porphyromonas gingivalis (P. gingivalis), were grown on the titanium and zirconia surfaces with two types of surface roughness for 24 and 72 h. Each bacterial biofilm on specimens was quantified using crystal violet assay and observed by scanning electron microscopy. S. gordonii formed more biofilm on the titanium surface than zirconia at the same roughness and more biofilm on the rough surface than smooth one of the same materials at 24 and 72 h of incubation. F. nucleatum adhered on all the surfaces at 24 h and proliferated actively on the surfaces except smooth zirconia at 72 h. P. gingivalis proliferated vigorously on the surfaces at 72 h while it scarcely adhered at 24 h. There was no consistent correlation between contact angle and biofilm formation of the three bacteria. The three bacteria proliferated most on the rough titanium surface and least on the smooth zirconia surface. In addition, the proliferation was affected by the bacterial species as well as the surface properties.

10 April 2019 in Materials
Verified
Journal Article
Open access
PDF file
Jae-Hyun LeeJae-Hyun Lee
Jae-Hyun Lee
SKSung-Hun Kim
Sung-Hun Kim
JHJung-Suk Han
Jung-Suk Han
In-Sung YeoIn-Sung Yeo
In-Sung Yeo
HYHyung-In Yoon
Hyung-In Yoon
This in vitro study investigated the impact of various dentifrices on the shade, translucency, gloss, and surface characteristics of polishing- or glazing-finished monolithic zirconia surfaces after simulated toothbrushing. Eighty square-shaped monolithic zirconia specimens were divided into two major groups based on the finishing methods—polished (P) and glazed (G). Next, specimens from the two major groups were categorized into four subgroups: stored in distilled water (DW, control); brushed with a fluoride-free conventional dentifrice (C); brushed with a fluoride dentifrice (F); and brushed with a whitening dentifrice (W). Overall, eight groups were created—PDW, PC, PF, PW, GDW, GC, GF, and GW (n = 10 each). Shade, translucency, surface gloss, surface roughness, crystalline phase, and superficial topography data were obtained. Repeated-measures ANOVA and two-way ANOVA were used for intergroup comparison (all α = 0.05). The color differences (ΔE00) between pre- and posttreatment were 0.3158 (PDW), 0.7164 (PC), 0.7498 (PF), 0.8106 (PW), 0.1953 (GDW), 0.301 (GC), 0.3051 (GF), and 0.4846 (GW). A statistically significant difference was observed among the ΔE00, surface gloss, and surface roughness of monolithic zirconia. Thus, brushing with several dentifrices markedly affects the optical properties and surface characteristics of monolithic zirconia finished with polishing or glazing methods.