Abdulrahman O. Al-Naseem

Abdulrahman O. Al-Naseem

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in Spine Deformity
Verified
Journal Article
Open access
PDF file
AAAbdulrahman O. Al-Naseem
Abdulrahman O. Al-Naseem
AAAbdullah Almehandi
Abdullah Almehandi
MRMohammad Ramadhan
Mohammad Ramadhan
AAAlwaleed Alfadhli
Alwaleed Alfadhli
YMYousef Marwan
Yousef Marwan
MAMuhammad M Abd-El-Barr
Muhammad M Abd-El-Barr
Purpose: The role of robotics in spine surgery remains controversial, especially for scoliosis correction surgery. This study aims to assess the safety and efficacy of robotic-assisted (RA) surgery specifically for scoliosis surgery by comparing RA to both navigation systems (NS) and conventional freehand techniques (CF). Methods: As per the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines, a systematic review and meta-analysis were conducted via an electronic search of the following databases: MEDLINE, EMBASE, and the Cochrane Central Register of Controlled Trials (CENTRAL). All papers comparing RA to either NS or CF for posterior spinal fusion in scoliosis were included. Fixed and random effects models of analysis were utilised based on analysis heterogeneity. Results: 10 observational studies were included in total. RA had significantly greater odds of accurate pedicle screw placement relative to both NS (OR = 2.02, CI = 1.52–2.67, p < 0.00001) and CF (OR = 3.06, CI = 1.79–5.23, p < 0.00001). The downside of RA was the significantly greater operation duration relative to NS (MD = 10.74, CI = 3.52–17.97, p = 0.004) and CF (MD = 40.27, CI = 20.90, p < 0.0001). Perioperative outcomes including estimated blood loss, radiation exposure, length of hospital stay, cobb angle correction rate, postoperative SRS score, VAS pain score, JOA score, as well as rates of neurological injury and revision surgery, were comparable between the groups (p > 0.05). Conclusion: RA offers significantly greater pedicle screw placement accuracy relative to NS and CF, however, surgery can take longer. In terms of perioperative outcomes, all three techniques are comparable.

9 January 2025 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LELoay Eleyan
Loay Eleyan
AGAhmed Gonnah
Ahmed Gonnah
IFImran Farhad
Imran Farhad
ALAser Labib
Aser Labib
AVAlisha Chakera Varia
Alisha Chakera Varia
DAVID HESKETH ROBERTSDAVID HESKETH ROBERTS
DAVID HESKETH ROBERTS
Heart Failure (HF) is a prevalent condition which places a substantial burden on healthcare systems worldwide. Medical management implemented with exercise training (ET) plays a role in prognostic and functional capacity improvement. The aim of this review is to determine the effect of exercise training (ET) on HFpEF and HFrEF patients as well as exercise modality recommendations in frail and sarcopenic subpopulations. Pharmacological therapy structures the cornerstone of management in HF reduced ejection fraction (HFrEF) and aids improved survival rates. Mortality reduction with pharmacological treatments in HF preserved ejection fraction (HFpEF) are yet to be established. Cardiac rehabilitation (CR) and ET can play an important role in both HFrEF and HFpEF. Preliminary findings suggest that CR significantly improves functional capacity, exercise duration, and quality of life. ET has shown beneficial effects on peak oxygen consumption (pVO2) and 6 min walk test distance in HFrEF and HFpEF patients, as well as a reduction in hospitalisation and mortality rates; however, the limited scope of larger trials reporting on this underscores the need for further research. ET also has been shown to have beneficial effects on depression and anxiety levels. High-intensity training (HIT) and moderate continuous training (MCT) have both shown benefits, while resistance exercise training and ventilatory assistance may also be beneficial. ET adherence rates are higher when enrolled to a supervised programme, but prescription rates remain low worldwide. Larger robust trials are required to determine ET’s effects on HF, as well as the most efficacious and personalised exercise prescriptions in HF subtypes.

17 March 2023 in European Journal of Endocrinology
Verified
Journal Article
Open access
PDF file
AAAbdulrahman O. Al-Naseem
Abdulrahman O. Al-Naseem
AAAhmed Attia
Ahmed Attia
AGAhmed Gonnah
Ahmed Gonnah
AAAbdulaziz O A S Al-Naseem
Abdulaziz O A S Al-Naseem
HSHarry Victor Michael Spiers
Harry Victor Michael Spiers
TATitus Augustine
Titus Augustine
Successful pancreas or islet transplantation is currently the only cure for type 1 diabetes mellitus. Since the first pancreas transplant in 1966, there have been various refinements of surgical technique along with improved immunosuppressive regimens, resulting in significantly improved outcomes, with contemporary research into graft monitoring and newer biomarkers, potentially lengthening graft survival rates further. Patients with insulin-dependent diabetes mellitus who are eligible for pancreas or islet transplantation represent a select group, the tip of the iceberg for a significant global diabetes disease burden. In the last 50 years, there have been quantum advances in alternative technologies in diabetes therapy, both experimental and translational. Further development and improved access are required to treat the larger proportion of people suffering from diabetes. Emerging stem cell therapy is still experimental whereas alternatives including automated insulin delivery systems and islet cell transplantation are already used in some countries. Whilst automated insulin delivery systems have increased in efficacy, they still do not achieve the near physiological control of blood sugar, which can be achieved by successful pancreas or islet transplantation. This state-of-the-art review provides a summary of pancreas and islet transplantation to its current place in diabetes therapy, along with alternative and future therapies, including the obstacles associated with the dissemination of these new therapies. With the advent of these modern cellular and technological advances, this review addresses the question: are we entering an era where whole organ pancreas transplantation could be replaced entirely by modern technological advances in diabetes therapy?

4 February 2025 in Spine Deformity
Verified
Journal Article
Closed access
PDF file
AAAbdulrahman O. Al-Naseem
Abdulrahman O. Al-Naseem
AAAbdulaziz Al-Naseem
Abdulaziz Al-Naseem
BBButhaina Al Balushi
Buthaina Al Balushi
YMYousef Marwan
Yousef Marwan
JLJulian Leong
Julian Leong
RSRoozbeh Shafafy
Roozbeh Shafafy

18 April 2022 in Cureus
Verified
Journal Article
Open access
AAAbdulrahman O. Al-Naseem
Abdulrahman O. Al-Naseem
AGAhmed R. Gonnah
Ahmed R. Gonnah
HAHussain Al-Ali
Hussain Al-Ali
ISIrfan Siddique
Irfan Siddique
Robotic-assisted navigation for percutaneous femoral neck fracture fixation is a new technology that has shown enhanced intraoperative and postoperative outcomes compared to the conventional freehand fluoroscopy-guided technique. The authors aim to compare robot-assisted femoral neck fracture fixation to conventional freehand fluoroscopy-guided repair. Electronic databases were searched, identifying all observational studies comparing outcomes of both groups. Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, a systematic review and meta-analysis were conducted. The primary outcomes included operative duration (minutes), intraoperative bleeding (mL), fluoroscopy exposure, and frequency of intraoperative drilling. The secondary outcomes included Harris scores, healing rate and time, screw accuracy, and postoperative complications. Seven observational studies were identified, enrolling 506 patients. There was a significant difference between the robot-assisted and conventional groups in terms of intraoperative blood loss (mean difference (MD) = -18.83, p ≤ 0.05), fluoroscopy exposure (MD = -1.81, p ≤ 0.05), and intraoperative drilling frequency (MD = -7.35, p < 0.05). There was no significant difference in operative duration between the groups (MD = -0.21, p = 0.66). Most secondary outcomes were improved in the robot-assisted group. Overall, robot-assisted fixation was superior in terms of safety and efficacy.

1 March 2024 in Global Spine Journal
Verified
Journal Article
Open access
AAAbdulrahman O. Al-Naseem
Abdulrahman O. Al-Naseem
AAAbdulaziz O Al-Naseem
Abdulaziz O Al-Naseem
DCDerek T Cawley
Derek T Cawley
AAAhmed Aoude
Ahmed Aoude
ACAnthony A Catanzano
Anthony A Catanzano
RSRoozbeh Shafafy
Roozbeh Shafafy
Study Design: Systematic literature review and meta-analysis. Objectives: Predicting patient risk of intraoperative neuromonitoring (IONM) alerts preoperatively can aid patient counselling and surgical planning. Sielatycki et al established an axial-MRI-based spinal cord classification system to predict risk of IONM alerts in scoliosis correction surgery. We aim to systematically review the literature on operative and radiologic factors associated with IONM alerts, including a novel spinal cord classification. Methods: A systematic review and meta-analysis was performed as per the Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) Guidelines. A literature search identifying all observational studies comparing patients with and without IONM alerts was conducted. Suitable studies were included. Patient demographics, radiological measures and operative factors were collected. Results: 11 studies were included including 3040 patients. Relative to type 3 cords, type 1 (OR = .03, CI = .01-.08, P < .00001), type 2 (OR = .08, CI = .03, P <.00001) and all non-type 3 cords (OR = .05, CI = .02-.16, P < .00001) were associated with significantly lower odds of IONM alerts. Significant radiographic measures for IONM alerts included coronal Cobb angle (MD = 10.66, CI = 5.77-15.56, P < .00001), sagittal Cobb angle (MD = 9.27, CI = 3.28-14.73, P = .0009), sagittal deformity angle ratio (SDAR) (MD = 2.76, CI = 1.57-3.96, P < .00001) and total deformity angle ratio (TDAR) (MD = 3.44, CI = 2.27-4.462, P < .00001). Clinically, estimated blood loss (MD = 274.13, CI = −240.03-788.28, P = .30), operation duration (MD = 50.79, CI = 20.58-81.00, P = .0010), number of levels fused (MD = .92, CI = .43-1.41, P = .0002) and number of vertebral levels resected (MD = .43, CI = .01-.84, P = .05) were significantly greater in IONM alert patients. Conclusions: This study highlights the relationship of operative and radiologic factors with IONM alerts.