Gianluigi De Gennaro

Dr. Gianluigi De Gennaro


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2011 in Sensors
Verified
Journal Article
Open access
PDF file
MBMagda Brattoli
Magda Brattoli
GGGianluigi De Gennaro
Gianluigi De Gennaro
VPValentina De Pinto
Valentina De Pinto
Annamaria Demarinis LoiotileAnnamaria Demarinis Loiotile
Annamaria Demarinis Loiotile
SLSara Lovascio
Sara Lovascio
Michele PenzaMichele Penza
Michele Penza
The complexity of the odours issue arises from the sensory nature of smell. From the evolutionary point of view olfaction is one of the oldest senses, allowing for seeking food, recognizing danger or communication: human olfaction is a protective sense as it allows the detection of potential illnesses or infections by taking into account the odour pleasantness/unpleasantness. Odours are mixtures of light and small molecules that, coming in contact with various human sensory systems, also at very low concentrations in the inhaled air, are able to stimulate an anatomical response: the experienced perception is the odour. Odour assessment is a key point in some industrial production processes (i.e., food, beverages, etc.) and it is acquiring steady importance in unusual technological fields (i.e., indoor air quality); this issue mainly concerns the environmental impact of various industrial activities (i.e., tanneries, refineries, slaughterhouses, distilleries, civil and industrial wastewater treatment plants, landfills and composting plants) as sources of olfactory nuisances, the top air pollution complaint. Although the human olfactory system is still regarded as the most important and effective “analytical instrument” for odour evaluation, the demand for more objective analytical methods, along with the discovery of materials with chemo-electronic properties, has boosted the development of sensor-based machine olfaction potentially imitating the biological system. This review examines the state of the art of both human and instrumental sensing currently used for the detection of odours. The olfactometric techniques employing a panel of trained experts are discussed and the strong and weak points of odour assessment through human detection are highlighted. The main features and the working principles of modern electronic noses (E-Noses) are then described, focusing on their better performances for environmental analysis. Odour emission monitoring carried out through both the techniques is finally reviewed in order to show the complementary responses of human and instrumental sensing.

21 April 2008 in Indoor Air
Verified
Journal Article
Open access
PDF file
PBP. Bruno
P. Bruno
MCM. Caselli
M. Caselli
GGGianluigi De Gennaro
Gianluigi De Gennaro
SIS. Iacobellis
S. Iacobellis
MTM. Tutino
M. Tutino
Abstract A weekly monitoring campaign of volatile organic compounds (VOC), with single sampling of 24 h, was carried out in non-residential indoor environments such as libraries, pharmacies, offices, gymnasiums, etc., in order to evaluate the VOC concentrations to which people are exposed. Moreover, an outdoor sample was coupled to each indoor site to point out the influence of indoor sources. They were sampled with Radiello® diffusive samplers for thermal desorption and analyzed by GC-MS. As already described in other papers, the VOC levels of most of the indoor sites were higher than that observed in the corresponding outdoor sites. For example, some sites showed a level of pollution that is ten times higher than their corresponding outdoor site. The monitored environments that had higher concentrations of the investigated VOC were the pharmacies, a newspaper stand, a copy center, and the coffee shops. Analysis of the weekly average concentrations of each pollutant and the use of literature allowed pointing out some site-specific characteristics that singled out possible sources of VOC. These results were verified analyzing the indoor-outdoor ratio (I/O) too. Newspaper stands were characterized by very high concentrations of toluene and pharmacies were characterized by high concentrations of aromatic compounds.

1 February 2004 in Annali di Chimica
Verified
Journal Article
Closed access
PDF file
LPLuca Pozzoli
Luca Pozzoli
SGStefania Gilardoni
Stefania Gilardoni
MPMaria Grazia Perrone
Maria Grazia Perrone
GGGianluigi De Gennaro
Gianluigi De Gennaro
MRMassimo de Rienzo
Massimo de Rienzo
DVDavide Vione
Davide Vione

1 June 2006 in Journal of Atmospheric Chemistry
Verified
Journal Article
Closed access
PDF file
PBP. Bruno
P. Bruno
MCM. Caselli
M. Caselli
GGGianluigi De Gennaro
Gianluigi De Gennaro
LGL. de Gennaro
L. de Gennaro
MTM. Tutino
M. Tutino

22 January 2014 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
MAM. Amodio
M. Amodio
PDP. R. Dambruoso
P. R. Dambruoso
GGGianluigi De Gennaro
Gianluigi De Gennaro
LGL. de Gennaro
L. de Gennaro
ALA. Demarinis Loiotile
A. Demarinis Loiotile
MTM. Tutino
M. Tutino

15 April 2008 in Water, Air, & Soil Pollution
Verified
Journal Article
Closed access
PDF file
PBPaolo Bruno
Paolo Bruno
MCMaurizio Caselli
Maurizio Caselli
GGGianluigi De Gennaro
Gianluigi De Gennaro
LSLucia Scolletta
Lucia Scolletta
LTLivia Trizio
Livia Trizio
MTMaria Tutino
Maria Tutino