Michele Penza

Dr. Michele Penza

ENEA - Italian National Agency for New Technologies, Energy and Sustainable Economic Development, Brindisi, Puglia, Italy
orcid
Top 2% World Scientist - Qualification Full Professor in a) ...

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 1998 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Michele PenzaMichele Penza
Michele Penza
CMC Martucci
C Martucci
GCG Cassano
G Cassano

1 December 2016 in Atmospheric Environment
Verified
Journal Article
Open access
CBC. Borrego
C. Borrego
ACA.M. Costa
A.M. Costa
JGJ. Ginja
J. Ginja
Marlene AmorimMarlene Amorim
Marlene Amorim
MCM. Coutinho
M. Coutinho
Michele PenzaMichele Penza
Michele Penza
The 1st EuNetAir Air Quality Joint Intercomparison Exercise organized in Aveiro (Portugal) from 13th–27th October 2014, focused on the evaluation and assessment of environmental gas, particulate matter (PM) and meteorological microsensors, versus standard air quality reference methods through an experimental urban air quality monitoring campaign. The IDAD-Institute of Environment and Development Air Quality Mobile Laboratory was placed at an urban traffic location in the city centre of Aveiro to conduct continuous measurements with standard equipment and reference analysers for CO, NOx, O3, SO2, PM10, PM2.5, temperature, humidity, wind speed and direction, solar radiation and precipitation.The comparison of the sensor data generated by different microsensor-systems installed side-by-side with reference analysers, contributes to the assessment of the performance and the accuracy of microsensor-systems in a real-world context, and supports their calibration and further development.The overall performance of the sensors in terms of their statistical metrics and measurement profile indicates significant differences in the results depending on the platform and on the sensors considered. In terms of pollutants, some promising results were observed for O3 (r2: 0.12–0.77), CO (r2: 0.53–0.87), and NO2 (r2: 0.02–0.89). For PM (r2: 0.07–0.36) and SO2 (r2: 0.09–0.20) the results show a poor performance with low correlation coefficients between the reference and microsensor measurements. These field observations under specific environmental conditions suggest that the relevant microsensor platforms, if supported by the proper post processing and data modelling tools, have enormous potential for new strategies in air quality control

16 May 2011 in Sensors
Verified
Journal Article
Open access
PDF file
MBMagda Brattoli
Magda Brattoli
GGGianluigi De Gennaro
Gianluigi De Gennaro
VPValentina De Pinto
Valentina De Pinto
Annamaria Demarinis LoiotileAnnamaria Demarinis Loiotile
Annamaria Demarinis Loiotile
SLSara Lovascio
Sara Lovascio
Michele PenzaMichele Penza
Michele Penza
The complexity of the odours issue arises from the sensory nature of smell. From the evolutionary point of view olfaction is one of the oldest senses, allowing for seeking food, recognizing danger or communication: human olfaction is a protective sense as it allows the detection of potential illnesses or infections by taking into account the odour pleasantness/unpleasantness. Odours are mixtures of light and small molecules that, coming in contact with various human sensory systems, also at very low concentrations in the inhaled air, are able to stimulate an anatomical response: the experienced perception is the odour. Odour assessment is a key point in some industrial production processes (i.e., food, beverages, etc.) and it is acquiring steady importance in unusual technological fields (i.e., indoor air quality); this issue mainly concerns the environmental impact of various industrial activities (i.e., tanneries, refineries, slaughterhouses, distilleries, civil and industrial wastewater treatment plants, landfills and composting plants) as sources of olfactory nuisances, the top air pollution complaint. Although the human olfactory system is still regarded as the most important and effective “analytical instrument” for odour evaluation, the demand for more objective analytical methods, along with the discovery of materials with chemo-electronic properties, has boosted the development of sensor-based machine olfaction potentially imitating the biological system. This review examines the state of the art of both human and instrumental sensing currently used for the detection of odours. The olfactometric techniques employing a panel of trained experts are discussed and the strong and weak points of odour assessment through human detection are highlighted. The main features and the working principles of modern electronic noses (E-Noses) are then described, focusing on their better performances for environmental analysis. Odour emission monitoring carried out through both the techniques is finally reviewed in order to show the complementary responses of human and instrumental sensing.

1 June 2004 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Michele PenzaMichele Penza
Michele Penza
FAF. Antolini
F. Antolini
MAM.Vittori Antisari
M.Vittori Antisari

1 July 1998 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Michele PenzaMichele Penza
Michele Penza
MTM.A Tagliente
M.A Tagliente
LML Mirenghi
L Mirenghi
CGC Gerardi
C Gerardi
CMC Martucci
C Martucci
GCG Cassano
G Cassano

23 April 2007 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
Michele PenzaMichele Penza
Michele Penza
GCG. Cassano
G. Cassano
RRR. Rossi
R. Rossi
MAM. Alvisi
M. Alvisi
Antonella RizzoAntonella Rizzo
Antonella Rizzo
RGR. Giorgi
R. Giorgi
Multiwalled carbon nanotube (MWCNT) films have been fabricated by using plasma-enhanced chemical vapor deposition system onto Cr–Au patterned alumina substrates, provided with 3nm thick Fe growth catalyst, for NO2 and NH3 gas sensing applications, at sensor temperature in the range of 100–250°C . Nanoclusters of noble metal surface catalysts (Au and Pt) have been sputtered on the surface of MWCNTs to enhance the gas sensitivity with respect to unfunctionalized carbon nanotube films. It was found that the gas sensitivity of Pt- and Au-functionalized MWCNT gas sensors significantly improved by a factor up to an order of magnitude through a spillover effect for NH3 and NO2 gas detections, respectively. The metal-functionalized MWCNT sensors exhibit very high gas sensitivity, fast response, reversibility, good repeatability, and sub-ppm range detection limit with the sensing properties of the MWCNT films tailored by surface catalyst used to functionalize the MWCNT sensors.