Aleksandra Królikowska

Prof. Aleksandra Królikowska

Ergonomics and Biomedical Monitoring Laboratory, Department of Physiotherapy, Faculty of Health Sciences, Wroclaw Medical University, Wroclaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2024 in Medicina
Verified
Journal Article
Open access
PDF file
JLJonathan Lettner
Jonathan Lettner
Aleksandra KrólikowskaAleksandra Królikowska
Aleksandra Królikowska
NRNikolai Ramadanov
Nikolai Ramadanov
Łukasz OleksyŁukasz Oleksy
Łukasz Oleksy
HHHassan Tarek Hakam
Hassan Tarek Hakam
Robert PrillRobert Prill
Robert Prill
Background and Objectives: Muscle properties are critical for performance and injury risk, with changes occurring due to physical exertion, aging, and neurological conditions. The MyotonPro device offers a non-invasive method to comprehensively assess muscle biomechanical properties. This systematic review evaluates the reliability of MyotonPro across various muscles for diagnostic purposes. Materials and Methods: Following PRISMA guidelines, a comprehensive literature search was conducted in Medline (PubMed), Ovid (Med), Epistemonikos, Embase, Cochrane Library, Clinical trials.gov, and the WHO International Clinical Trials platform. Studies assessing the reliability of MyotonPro across different muscles were included. A methodological quality assessment was performed using established tools, and reviewers independently conducted data extraction. Statistical analysis involved summarizing intra-rater and inter-rater reliability measures across muscles. Results: A total of 48 studies assessing 31 muscles were included in the systematic review. The intra-rater and inter-rater reliability were consistently high for parameters such as frequency and stiffness in muscles of the lower and upper extremities, as well as other muscle groups. Despite methodological heterogeneity and limited data on specific parameters, MyotonPro demonstrated promising reliability for diagnostic purposes across diverse patient populations. Conclusions: The findings suggest the potential of MyotonPro in clinical assessments for accurate diagnosis, treatment planning, and monitoring of muscle properties. Further research is needed to address limitations and enhance the applicability of MyotonPro in clinical practice. Reliable muscle assessments are crucial for optimizing treatment outcomes and improving patient care in various healthcare settings.

12 February 2025 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Closed access
MKMahmut Enes Kayaalp
Mahmut Enes Kayaalp
RPRobert Prill
Robert Prill
ESErdem Aras Sezgin
Erdem Aras Sezgin
TCTing Cong
Ting Cong
Aleksandra KrólikowskaAleksandra Królikowska
Aleksandra Królikowska
MHMichael T. Hirschmann
Michael T. Hirschmann

9 December 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Robert PrillRobert Prill
Robert Prill
MWMarina Walter
Marina Walter
Aleksandra KrólikowskaAleksandra Królikowska
Aleksandra Królikowska
RBRoland Becker
Roland Becker
In clinical practice, only a few reliable measurement instruments are available for monitoring knee joint rehabilitation. Advances to replace motion capturing with sensor data measurement have been made in the last years. Thus, a systematic review of the literature was performed, focusing on the implementation, diagnostic accuracy, and facilitators and barriers of integrating wearable sensor technology in clinical practices based on a Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. For critical appraisal, the COSMIN Risk of Bias tool for reliability and measurement of error was used. PUBMED, Prospero, Cochrane database, and EMBASE were searched for eligible studies. Six studies reporting reliability aspects in using wearable sensor technology at any point after knee surgery in humans were included. All studies reported excellent results with high reliability coefficients, high limits of agreement, or a few detectable errors. They used different or partly inappropriate methods for estimating reliability or missed reporting essential information. Therefore, a moderate risk of bias must be considered. Further quality criterion studies in clinical settings are needed to synthesize the evidence for providing transparent recommendations for the clinical use of wearable movement sensors in knee joint rehabilitation.

30 October 2023 in Knee Surgery, Sports Traumatology, Arthroscopy
Verified
Journal Article
Open access
PDF file
Aleksandra KrólikowskaAleksandra Królikowska
Aleksandra Królikowska
PRPaweł Reichert
Paweł Reichert
JKJon Karlsson
Jon Karlsson
CMCaroline Mouton
Caroline Mouton
RBRoland Becker
Roland Becker
RPRobert Prill
Robert Prill
A large space still exists for improving the measurements used in orthopaedics and sports medicine, especially as we face rapid technological progress in devices used for diagnostic or patient monitoring purposes. For a specific measure to be valuable and applicable in clinical practice, its reliability must be established. Reliability refers to the extent to which measurements can be replicated, and three types of reliability can be distinguished: inter‐rater, intra‐rater, and test–retest. The present article aims to provide insights into reliability as one of the most important and relevant properties of measurement tools. It covers essential knowledge about the methods used in orthopaedics and sports medicine for reliability studies. From design to interpretation, this article guides readers through the reliability study process. It addresses crucial issues such as the number of raters needed, sample size calculation, and breaks between particular trials. Different statistical methods and tests are presented for determining reliability depending on the type of gathered data, with particular attention to the commonly used intraclass correlation coefficient.

27 June 2018 in BioMed Research International
Verified
Journal Article
Open access
PDF file
ACAgata Cieślik-Bielecka
Agata Cieślik-Bielecka
TBTadeusz Bold
Tadeusz Bold
GZGrzegorz Ziółkowski
Grzegorz Ziółkowski
MPMarcin Pierchała
Marcin Pierchała
Aleksandra KrólikowskaAleksandra Królikowska
Aleksandra Królikowska
PRPaweł Reichert
Paweł Reichert
The aim of the study was to investigate the leukocyte- and platelet-rich plasma (L-PRP) antimicrobial activity. The studied sample comprised 20 healthy males. The L-PRP gel, liquid L-PRP, and thrombin samples were testedin vitrofor their antibacterial properties against selected bacterial strains using the Kirby-Bauer disc diffusion method. Two types of thrombin were used (autologous and bovine). Zones of inhibition produced by L-PRP ranged between 6 and 18 mm in diameter. L-PRP inhibited the growth ofStaphylococcus aureus(MRSA and MSSA strains) and was also active againstEnterococcus faecalisandPseudomonas aeruginosa. There was no activity againstEscherichia coliandKlebsiella pneumoniae. The statistically significant increase of L-PRP antimicrobial effect was noted with the use of major volume of thrombin as an activator. Additionally, in groups where a bovine thrombin mixture was added to L-PRP the zones of inhibition concerning MRSA,Enterococcus faecalis, andPseudomonas aeruginosawere larger than in the groups with autologous thrombin. Based on the conducted studies, it can be determined that L-PRP can evokein vitroantimicrobial effects and might be used to treat selected infections in the clinical field. The major volume of thrombin as an activator increases the strength of the L-PRP antimicrobial effect.

20 December 2024 in Medicina
Verified
Journal Article
Open access
PDF file
MOMarko Ostojic
Marko Ostojic
Pier Francesco IndelliPier Francesco Indelli
Pier Francesco Indelli
BLBruno Lovrekovic
Bruno Lovrekovic
JVJérôme Valcarenghi
Jérôme Valcarenghi
DJDoria Jurić
Doria Jurić
Robert PrillRobert Prill
Robert Prill
Anterior cruciate ligament (ACL) injuries are common in sports and often require surgical intervention, e.g., ACL reconstruction (ACLR), aimed at restoring knee stability and enabling a return to pre-injury activity levels. The choice of graft is crucial, impacting biomechanical properties, clinical outcomes, and complication rates, and is especially important in revision surgeries after graft failure. Over the past 30 years, trends in graft selection have evolved towards more individualized approaches, considering factors such as patient activity level, prior injuries, and tissue availability. In Europe, autografts like hamstring tendon (HT), bone-patellar tendon-bone (BTB), and quadriceps tendon (QT) are preferred, with the increasing use of QT grafts. This review synthesizes the current literature on graft selection and its influence on ACLR outcomes.